ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Analytica Chimica Acta 272 (1993), S. 139-143 
    ISSN: 0003-2670
    Keywords: Amperometry ; Cadmium ; Indium ; Overlapped peaks ; Voltammetry
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 40 (1992), S. 163-167 
    ISSN: 1741-0444
    Keywords: Cardiac ischaemia ; Cyclic variation in integrated backscatter ; Fusion image ; Integrated backscatter ; Myocardium ; Ultrasound
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Quantitative ultrasonic tissue characterisation of the myocardium based on integrated backscatter (IB) has the potential of becoming an effective method for detecting and evaluating myocardial ischaemia. To facilitate IB-based clinical applications, a new imaging method has been developed that combines the anatomical information of a B-mode image with the contractile performance of a selected myocardial region. To produce such a fusion image, a region of interest (ROI) in a B-mode cardiac image was first selected by the user. Algorithms for detection of the endocardium andepicardium were developed, and the resulting mean distance between the computer-detected curve and the manually traced curve was 0.83 mm for the endocardium and 0.58 mm for the epicardium. The cyclic variation of IB (CVIB) of each myocardial tissue element within the ROI was then calculated over one cardiac cycle. Finally, a grey-scale B-mode image at the end of diastole was displayed as a still image, and the pixels representing the myocardial tissue in the ROI colour-coded according to the corresponding CVIB over the past heart cycle. Both the B-mode image and the colour-coded region were refreshed (up-dated) at the next end-of-diastole. Preliminary results from normal (CVIB=10–12dB) and ischaemic (CVIB=5–7 dB) canine hearts are presented that demonstrate the utility of this new imaging method.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    International Journal for Numerical Methods in Fluids 18 (1994), S. 449-469 
    ISSN: 0271-2091
    Keywords: Body-fitted co-ordinates ; Non-orthogonal grids ; Physical geometric quantities ; Incompressible flow ; Coupled equation solver ; Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: This paper presents a numerical method for fluid flow in complex three-dimensional geometries using a body-fitted co-ordinate system. A new second-order-accurate scheme for the cross-derivative terms is proposed to describe the non-orthogonal components, allowing parts of these terms to be treated implicitly without increasing the number of computational molecules. The physical tangential velocity components resulting from the velocity expansion in the unit tangent vector basis are used as dependent variables in the momentum equations. A coupled equation solver is used in place of the complicated pressure correction equation associated with grid non-orthogonality. The co-ordinate-invariant conservation equations and the physical geometric quantities of control cells are used directly to formulate the numerical scheme, without reference to the co-ordinate derivatives of transformation. Several two- and three-dimensional laminar flows are computed and compared with other numerical, experimental and analytical results to validate the solution method. Good agreement is obtained in all cases.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...