ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • COMMUNICATIONS AND RADAR  (1)
  • Forensics  (1)
  • 1
    ISSN: 0173-0835
    Keywords: Individual identification ; Short tandem repeats ; Multiplex ; Forensics ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Short tandem repeat (STR) loci are routinely employed for individual identification. We have examined the performance and reproductibility of a highly informative co-amplification system containing the tetranucleotide STR loci: HUMVWFA31/A, HUMTH01, D20S85, D8S1179, HUMFIBRA, D21S11, and D18S51, in conjunction with the amelogenin sex test, in addition to a modified system omitting the locus D20S85. Polymerase chain reaction (PCR) products were fluorescently detected on an automated sequencer and automatically sized against an internal size standard by Genescan software. Both systems were routinely able to type 500 pg of undegraded DNA. At DNA concentrations between 50-500 pg, partial profiles were produced, but no allelic drop-out was observed. Balanced amplification of all loci occurred over a wide range of DNA concentrations from 50 pg to 10 ng. Alteration of reagent concentrations and cycling parameters from optimal resulted in variation in the efficiency of individual locus amplification relative to the other loci within the system. This was also observed at high ionic strength or extreme pH. However, at all reagent concentrations and conditions, allelic drop-out was not observed. These multiplex systems have potential in both routine forensic and intelligence database applications.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-06-28
    Description: A jointly optimized coded modulation system is described which was designed, built, and tested by COMSAT Laboratories for NASA LeRC which provides a bandwidth efficiency of 2 bits/s/Hz at an information rate of 160 Mbit/s. A high speed rate 8/9 encoder with a Viterbi decoder and an Octal PSK modem are used to achieve this. The BER performance is approximately 1 dB from the theoretically calculated value for this system at a BER of 5 E-7 under nominal conditions. The system operates in burst mode for downlink applications and tests have demonstrated very little degradation in performance with frequency and level offset. Unique word miss rate measurements were conducted which demonstrate reliable acquisition at low values of Eb/No. Codec self tests have verified the performance of this subsystem in a stand alone mode. The codec is capable of operation at a 200 Mbit/s information rate as demonstrated using a codec test set which introduces noise digitally. The measured performance is within 0.2 dB of the computer simulated predictions. A gate array implementation of the most time critical element of the high speed Viterbi decoder was completed. This gate array add-compare-select chip significantly reduces the power consumption and improves the manufacturability of the decoder. This chip has general application in the implementation of high speed Viterbi decoders.
    Keywords: COMMUNICATIONS AND RADAR
    Type: NASA-CR-185149 , NAS 1.26:185149 , CTD-90/022
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...