ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Blood pressure  (4)
  • ELECTRONICS AND ELECTRICAL ENGINEERING  (4)
  • Arterial elasticity  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 19 (1981), S. 671-672 
    ISSN: 1741-0444
    Keywords: Blood pressure ; Pulse-arrival-time method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Annals of biomedical engineering 10 (1982), S. 271-280 
    ISSN: 1573-9686
    Keywords: Blood pressure ; Oscillometric method ; Hypertension ; Accuracy ; Systolic blood pressure ; Diastolic blood pressure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract In this study, human subjects and dogs were used to determine the ability of the oscillometric method to indicate systolic and diastolic pressure. In the human studies, the auscultatory method was used as the reference. In the animal studies, directly recorded blood pressure was used as the reference. The ability of the sudden increase in cuff pressure oscillations during cuff deflation to indicate systolic pressure was examined and found to overestimate systolic pressure slightly in man, but more in animals. Systolic pressure was encountered when the cuff pressure oscillations were about one half of their maximum amplitude. However, in both man and animals the ratio was not constant; although the range was less in man than in animals. Diastolic pressure was encountered when cuff-pressure oscillation amplitude was about 0.8 of the maximal amplutide. This ratio for diastolic pressure was not constant over a range of diastolic pressure. The range of variability was less for man than for the dog.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Annals of biomedical engineering 16 (1988), S. 341-347 
    ISSN: 1573-9686
    Keywords: Pulse wave velocity ; Blood pressure ; Algorithm
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract The relationship between pulse-wave velocity (PWV) and blood pressure was investigated using a new method in which multiple pulse-wave velocities were determined within each blood-pressure pulse. The technique employed measuring pressure at two sites within the aorta and measuring multiple time differences between each pair of pressure waves. Blood pressure was manipulated with drugs. The technique of obtaining multiple PWVs within a beat dramatically reduced the variability of the data in the linear and nonlinear region of PWV versus pressure relationship.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 24 (1986), S. 248-254 
    ISSN: 1741-0444
    Keywords: Arterial elasticity ; Pulse-wave velocity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Pulse wave velocity (PWV) was measuredin situ in 11 isolated canine common carotid arteries. Seven arteries exhibited a linear PWV/pressure function at pressures ranging from 0 to 200 mm Hg. Four arteries yielded a linear relationship between PWV and pressure between 1 and 100 mm Hg; for these vessels the relationship was nonlinear at higher pressures. Seven arteries (five from the group which was linear up to 200 mm Hg and two from the group which was linear up to 100 mm Hg) were excised and presure/volume measurements were madein vivo. Using pressure/volume data, the Moens-Korteweg equation was evaluated as a predictor of the PWV/pressure relationship over the linear region. An expression was developed to anable prediction of the pressure/volume relationship using the coefficients at the linear PWV/pressure function; these predictions were evaluated. We found that, for this range, the Moens-Korteweg equation provides a very good basis for predicting the increase in PWV with increasing bias pressure. In addition, we found that the pressure/volume relationship of common carotid arteries is well represented by an exponential of the form V/Vo=Keαf(P), which was derived as the inverse solution to the Moens-Korteweg equation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 22 (1984), S. 613-614 
    ISSN: 1741-0444
    Keywords: Blood pressure ; Transducers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 23 (1985), S. 197-202 
    ISSN: 1741-0444
    Keywords: Aortic dimensions ; Arterial compliance ; Arterial elasticity ; Ultrasonic aortography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract The radii of the inner and outer walls of the aorta and the intravascular blood pressure were recorded simultaneously in the descending thoracic aorta of intact, living dogs using 7·5 MHz ultrasound. Blood pressure and the A-mode signals containing wall echoes were also recorded on videotape which was later replayed for processing. Thein vivo data were compared with data obtained on the same vessels post mortem. The change in radius due to a pressure change from 80 to 125 mmHg was calculated from thein vivo andin vitro data. After normalising the radius changes with respect to the radius at 80 mm Hg, the ratio of thein vivo andin vitro values ranged from 0·66 to 1·36 with a mean of 0·94. The changes in radius were comparable with previously reported values obtained using various techniques.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-06-28
    Description: This report is a technology assessment relevant to the 30 GHz Monolithic Receive Module development. It is based on results obtained on the present NASA Contract (NAS3-23356) as well as on information gathered from literature and other industry sources. To date the on-going Honeywell program has concentrated on demonstrating the so-called interconnected receive module which consists of four monolithic chips - the low noise front-end amplifier (LNA), the five bit phase shifter (PS), the gain control amplifier (GC), and the RF to IF downconverter (RF/IF). Results on all four individual chips have been obtained and interconnection of the first three functions has been accomplished. Future work on this contract is aimed at a higher level of integration, i.e., integration of the first three functions (LNA + PS + GC) on a single GaAs chip. The report presents the status of this technology and projections of its future directions.
    Keywords: ELECTRONICS AND ELECTRICAL ENGINEERING
    Type: NASA-CR-180825 , NAS 1.26:180825
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-06-28
    Description: The design and performance of a GaAs monolithic 180-degree one-bit switched line phase shifter test circuit for Ka-band operation is presented. A self-aligned gate (SAG) fabrication technique is also described that reduces resistive parasitics in the switching FET's. Over the 27.5-30 GHz band, typical measured differential insertion phase is within 10-20 deg of the ideal time delay characteristic. Over the same band, the insertion loss for the SAG phase shifter is about 2.5-3 dB per bit. The SAG fabrication technique holds promise in reducing phase shifter insertion loss to about 1.5 dB/bit for 30-GHz operation.
    Keywords: ELECTRONICS AND ELECTRICAL ENGINEERING
    Type: IEEE Transactions on Microwave Theory and Techniques (ISSN 0018-9480); MTT-31; 1077-108
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-07-27
    Description: A monolithic two stage gain control amplifier has been developed using submicron gate length dual gate MESFETs fabricated on ion implanted material. The amplifier has a gain of 12 dB at 30 GHz with a gain control range of over 30 dB. This ion implanted monolithic IC is readily integrable with other phased array receiver functions such as low noise amplifiers and phase shifters.
    Keywords: ELECTRONICS AND ELECTRICAL ENGINEERING
    Type: IEEE, 1987 Microwave and Millimeter-Wave Monolithic Circuits Symposium; June 8 , 9, 1987; Las Vegas, NV; United States
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2019-07-12
    Description: A monolithic gain control amplifier for Ka-band has been developed based on 0.25 micron-gate-length dual-gate FETs fabricated on ion-implanted material. A single-stage monolithic amplifier gives a gain of 6 dB at 31 GHz including fixture losses with a gain control range of over 20 dB. The device and IC design and fabrication are described.
    Keywords: ELECTRONICS AND ELECTRICAL ENGINEERING
    Type: Electronics Letters (ISSN 0013-5194); 22; 503
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...