ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0173-0835
    Keywords: Antibiotics ; Chiral separations ; Enantiomers ; Drugs ; Herbicides ; Capillary electrophoresis ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: A new glycopeptide antibiotic, MDL 63,246 (Hepta-tyr), of the teicoplanin family, has been evaluated in capillary electrophoresis for the resolution of chiral compounds of pharmaceutical and environmental interest. Electrophoretic separations were carried out in a polyacrylamide-coated capillary using the partial filling-counter current mode with aqueous-organic buffers in the pH range 4-6. Experimental parameters affecting resolution, such as antibiotic concentration, buffer pH, organic modifier type and capillary temperature, were studied. The Hepta-tyr antibiotic exhibited a high enantiorecognition capability towards the studied compounds at very low concentrations (1-2 mg/mL). The optimum experimental conditions were achieved by using a buffer at pH 5 containing acetonitrile at 25°C.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 19 (1998), S. 2883-2889 
    ISSN: 0173-0835
    Keywords: Tramadol ; Enantiomers ; Cyclodextrins ; Capillary zone electrophoresis ; Validation ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Capillary zone electrophoresis was successfully applied to the enantiomeric resolution of racemic tramadol. Both uncoated and polyacrylamide-coated capillaries were tested for method optimization using either negatively charged or native cyclodextrins (CD) added to the background electrolyte (BGE). The resolution was strongly influenced by the CD type and concentration as well as by the pH and the concentration of the BGE. Among the CDs tested, carboxymethylated-β-cyclodextrin allowed the baseline separation of tramadol enantiomers. After the method was optimized, it was validated in a coated capillary for enantiomeric analysis of tramadol enantiomers in pharmaceutical formulation, including specificity and elution order, linearity, accuracy and precision, determination of limit of detection (LOD) and quantification (LOQ), enantiomeric purity linearity, freedom from interference, and stability of sample solutions. Precision at the target concentration was less than 2%, with an accuracy higher than 99%. Furthermore, the method was able to detect 0.3% and to quantify 1% of the minor enantiomer in the presence of the major one at the target value.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...