    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The fast-evaporation method of sample preparation has been applied for quantitative analysis using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. An instrumental protocol focusing on improvement of shot-to-shot repeatability and compensation for signal degradation has been developed for quantification of angiotensin II using the fast-evaporation technique and an internal standard. The fast-evaporation method was compared to the standard method of sample preparation (using a multicomponent matrix) in the quantitative analysis of angiotensin II, and found to be superior in several respects. Improvement in sample homogeneity using the fast-evaporation method enhanced both point-to-point repeatibility and sample-to-sample reproducibility. The relative standard deviations of the analyte/internal standard ratios (point RSD) were decreased by a factor of three compared to those obtained using the multicomponent matrix method. The average point RSD was found to be ca. 5% for the fast-evaporation technique. Two internal standards were evaluated for quantification of angiotensin II. The better one, 1-SAR-8-Ile angiotensin II, yielded a relative standard deviation of the standard curve slope of ca. 2.2% over two orders of magnitude of concentration (45 nM to 3000 nM), an improvement by a factor of two over the standard preparation method. Renal microdialysate samples, spiked with angiotensin II and the internal standard 1-SAR-8-Ile angiotensin II, were also analyzed using the fast-evaporation technique. The detection limit was calculated to be in the high attomole range (675amol). Furthermore, the accuracy for a single determination of angiotensin II concentration in these samples was found to be 13.9% with a relative error of 8.19%.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...