ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (42)
  • Polymer, Soft Matter, Biological, and Interdisciplinary Physics
  • 1
    Publication Date: 2014-11-26
    Description: Author(s): Laura Toppozini, Sebastian Meinhardt, Clare L. Armstrong, Zahra Yamani, Norbert Kučerka, Friederike Schmid, and Maikel C. Rheinstädter Rafts, or functional domains, are transient nano-or mesoscopic structures in the plasma membrane and are thought to be essential for many cellular processes such as signal transduction, adhesion, trafficking, and lipid or protein sorting. Observations of these membrane heterogeneities have proven ch... [Phys. Rev. Lett. 113, 228101] Published Tue Nov 25, 2014
    Keywords: Polymer, Soft Matter, Biological, and Interdisciplinary Physics
    Print ISSN: 0031-9007
    Electronic ISSN: 1079-7114
    Topics: Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2016-02-09
    Description: Author(s): Markus Rein, Nike Heinß, Friederike Schmid, and Thomas Speck We study a generic model for quorum-sensing bacteria in circular confinement. Every bacterium produces signaling molecules, the local concentration of which triggers a response when a certain threshold is reached. If this response lowers the motility, then an aggregation of bacteria occurs which dif… [Phys. Rev. Lett. 116, 058102] Published Fri Feb 05, 2016
    Keywords: Polymer, Soft Matter, Biological, and Interdisciplinary Physics
    Print ISSN: 0031-9007
    Electronic ISSN: 1079-7114
    Topics: Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 257-259 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Dihydro dimethyl ethers of vitamin K1 ; Separtion of diastereomers ; Characterization of source of vitamin K1 samples ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is described for the gas-chromatographic determination of the diastereomers of vitamin K1 (phylloquinone) in the form of their dihydro dimethyl ethers. The reported method of derivatization and chromatographic analysis in conjunction with optical rotation measurements are useful approaches for characterization of vitamin K1 samples with respect to their origin.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 225-228 
    ISSN: 0935-6304
    Keywords: GC/MS Interface ; Glass ; Open split ; HMDS glass surface deactivation ; Glass capillary columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new all-glass interface for GC/MS designed to fully exploit the potential of glass capillary columns is described. The system works in the open split mode and has high versatility with respect to column changing. It is especially suitable for mass spectrometers, which are not exclusively dedicated to GC/MS work. Two chromatograms illustrate the properties of the described interface.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 675-676 
    ISSN: 0935-6304
    Keywords: Triglycerides ; GC/MS of triglycerides ; Capillary, glass ; All-glass GC/MS interface ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0935-6304
    Keywords: Gas chromatography ; FID and FPD ; Azinphos-methyl, -ethyl and six metabolites ; Beta vulgaris leaves ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 10 (1987), S. 548-552 
    ISSN: 0935-6304
    Keywords: Glass capillary gas chromatography ; Immobilization ; OV-240-OH cyanopropylpolysiloxane ; Isomer specificity ; Polychlorinated dibenzo-p-dioxins ; Polychlorinated dibenzofurans ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Glass capillaries were leached, dehydrated, persilylated with 1, 3-bis (3-cyanopropyl) tetramethyldisiloxane, and coated with OV-240-OH. After crosslinking and binding the phase to the glass surface the columns showed high separation efficiency, high temperature stability, and inertness comparable to persilylated apolar columns. Column performance is shown to be superior to liquid phase cyanopropyl columns such as SP 2330. The excellent separation capabilities together with the selectivity of the phase makes OV-240-OH coated columns a valuable tool for the determination of toxic isomers in complex mixtures of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). The order of elution of individual TCDD isomers was found to be similar to that described for SP 2330 or Silar 10c. The detection of PCDDs and PCDFs in a fly ash extract further illustrates the utility of OV-240-OH coated columns. The high temperature limit of these columns opens the way for the analysis of high boiling compounds such as mixed brominated/chlorinated dibenzo-p-dioxins and dibenzofurans.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 665-668 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Glass capillary columns ; OH-Terminated polysiloxane phases ; PS-347.5, OV-17-OH, OV-240-OH ; SP-2330 ; Polychlorinated dibenzo-p-dioxin ; Polychlorinated dibenzofuran ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Glass capillaries coated with four crosslinked and surface-bonded OH-terminated polysiloxanes [PS 347.5, OV-17-OH, OV-225-OH, and OV-240-OH] were compared with commonly used methyl-terminated SP-2330-coated columns with respect to their selectivity for the separation of 2,3,7,8-chloro-substituted dibenzo-p-dioxins and dibenzofurans. The methyl- and phenyl-substituted phases [PS 347.5 and OV-17-OH] exhibit only moderate isomer selectivity which limits their applicability in this field. The examined 3-cyanopropyl-substituted phases [OV-225-OH, OV-240-OH, and SP-2330] allow complete separation of all 2,3,7,8-chlorosubstituted PCDDs and PCDFs. With SP-2330 longer columns are required (50 m) for baseline separation of critical groups of isomers. OV-225-OH was found to be the most suitable phase as to isomer selectivity. In comparison to SP-2330, the analysis times can be reduced by a factor of two.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 17 (1988), S. 415-416 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 22 (1993), S. 133-142 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Collision-induced dissociation (CID) methods are described for the quantification of nanogram per millilitre (ppb) concentrations of 2-acetamido-3-(3′-hydroxypropylthio)-propanoic acid (I) and 2-acetamido-3-phenylthiopropanoic acid (II) in human urine extracts. I and II are potential detoxification products of acrolein and benzene in conjugation with N-acetyl(-L-)cysteine derived from glutathione. We have studied the potential of tandem mass spectrometry (MS/MS) under electron impact (EI) and chemical ionization (CI) conditions as a confirmatory screening technique for these compounds. Our main goals were high selectivity and low detection limits along with little or no sample clean-up. The effects of the mode of ionization and of collision conditions on the CID spectra have been investigated. Direct insertion probe without any derivatization or short-column gas chromatographic separation techniques are used. Total instrument and data analysis time is about 15 min for direct insertion probe MS/MS and about 30 min for short-column gas chromatography (GC)/MS/MS. Detection limits are: direct insertion probe MS/MS (EI mode), 50 ppb (100 pg) for compound I; short-column GC/MS/MS (EI mode), 1.5 ppb (5 pg) for compound II; and short-column GC/MS/MS (CI mode), 0.6 ppb (2 pg) for the methyl ester of compound II. Results are compared with non-mass spectrometric methods. The MS/MS methods were applied for the determination of I (EI mode) and II (CI mode) in urinary samples of a smoker and eight non-smokers. After smoking, the urinary levels of I and II were elevated, whereas no increase was observed after experimental passive smoking.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...