ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (2,665)
  • FLUID MECHANICS AND HEAT TRANSFER
Collection
Keywords
Publisher
  • 1
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The data obtained with 252Cf plasma desorption (PD) and fast atom bombardment mass spectrometry of eight tri-, tetra- and pentapeptides were compared. Good spectra were obtained with 1-10 nmol of peptide. In both techniques molecular weight information was obtained. The PD mass spectra are often dominated by the cationized molecular ions in contrast to the fast atom bombardment (FAB) mass spectra, where cationization is rarely observed. Amino acid content is reflected in the immonium ions equally well in both techniques. The fragmentation patterns observed with the two techniques are almost identical. However, practical sequencing of peptides based on either FAB or PD mass spectrometry of underivatized peptides alone is difficult. This is due to the unpredictable and sometimes absent cleavage yield at certain peptide bonds. Another difficulty is the many simultaneous fragmentation pathways. However, for many peptides enough information is present to allow sequence determination for at least a major part of the molecule.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0049-8246
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: It was demonstrated that a total reflection x-ray fluorescence spectrometer, using monoenergetic synchrotron radiation as the primary x-ray source, is suitable to measure the concentration of transmutational elements in Cu and Fe metal matrices. In a typical irradiation of copper with 590 MeV protons or with spallation neutrons, where the damage dose is 0.4 dpa (displacement per atom), the calculated concentration of transmutational elements is Ni 25, Co 8 and Fe 8 μg g-1. The results show that the minimum detectable concentrations were lower than these values. The energy of the sychrotron radiation was set just below the K-edge energy of the matrix element, eliminating the large peak due to the matrix. As an example, in the case of a Cu (Z = 29) matrix, the minimum detectable concentration for Ni (Z = 28) was as low as 3 μg g-1. In order to check systematically the possible geometric arrangements of beam direction-reflector position-detector position, a new vacuum chamber was designed and tested. It provides all technical components for remote control of the adjustment procedure to align the reflector in total reflection geometry. Two ways of positioning the reflector in the beam, vertical to the plane of polarization and parallel to that plane, were investigated, to find the best excitation conditions and lowest limits of detection. A few pg corresponding to a concentration of ng g-1 of samples where the matrix can be easily removed as in aqueous or acidic solutions and 50 ng g-1 concentration of metals in a light matrix as in oil were found as detection limits.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0935-6304
    Keywords: Capillary electrophoresis ; Run-to-run reproducibility ; Capillary thermostatting ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Run-to-run sample separation reproducibility has been compared on two commercial high performance capillary electrophoresis units which differ in the mode by which the capillary temperature is thermostatted. Three standard analytes, differing dramatically in molecular character and size, were used for the analysis: benzoic acid, a 14 amino acid peptide from human chorionic gonadotropin, and ribonuclease A represent, respectively, small stable organic molecules, small peptides with little or no secondary structure, and proteins with secondary structure. These standards were evaluated with regard to reproducibility of migration time, peak area, and peak height. The analyses, performed in buffers of optimum pH for the separations, demonstrated that the liquid and forced air convection thermostatted systems both performed extremely well. The reproducibility, as judged by the percent coefficient of variance (% CV) of replicate analyses, was generally found to be less than 1 % (migration time); the reproducibility decreased in the order migration time 〉 peak height 〉 peak area. Whereas the absolute % CV values for MTrel (migration relative to a standard) observed with the liquid thermostatted system were 2- to 4-fold lower than those observed with the forced air convection thermostatted system, there was little statistically significant difference between the two. As expected, the data indicated a reduction in reproducibility as the complexity of the analyte increased, perhaps as the result of an increased potential for wall interactions. Comparing separations in which low (≍1 watt/meter [W/m] of capillary) and high (〉5 W/m) Joule heat was generated by altering the sodium chloride content of the buffer revealed few statistically significant differences in the reproducibility obtained from the two systems. With these particular standard analytes and their respective buffer systems, there appears to be little difference between forced air convection and liquid thermostatting of the capillary.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The mass spectrometric behaviour of ten variously substituted mono- and bis-salicylaldimine derivatives has been studied by fast-atom bombardment and metastable-ion studies. In general, well detectable protonated molecules are present and fragmentation processes mainly related to aldimine chain cleavages are evidenced. Interesting cyclization reactions leading to particularly stable product ions are discussed.
    Additional Material: 4 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Plasma desorption time-of-flight mass spectrometry (PD-TOFMS) using accelerated argon ions (9 MeV) has been successfully used for characterizing the surface modifications induced at the surface of poly(ether etherketone) (PEEK) by cold plasma treatments. While the intact polymer structure leads to the emission of negative ions from fragmentation of the repeat unit, the degradation of such a structure under plasma exposure gives rise to production of oxidized fragments. It is demonstrated that this production is highest for a plasma using a mixture of O2 and N2 (20:80), and that as a function of treatment duration, the rate of oxidation of the modified surface layer correlates with adhesive strength, at least in a first step. PD-TOFMS is used for analysis of the failure patterns of epoxyamine adhesive/PEEK/carbon composite in order to localize the fracture position. It is concluded that the increase of the cohesion of the interphase layer as a function of the plasma treatment duration leads to a shift from the interphase/PEEK interface to the bulk of the matrial.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The urines of children with neonatal adrenoleukodystrophy and Zellweger syndrome contained an excess of unusual even- and odd-numbered dicarboxylic acids with a chain length of from 5 to 15 carbon atoms, as well as 2-hydroxy-compounds, including 2-hydroxy-isocaproate, 2-hydroxy-glutarate and 2-hydroxy-sebacate. The latter product, not previously found in metabolic diseases, appears as an additional useful marker of these peroxisomal disorders.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 6 (1992), S. 741-746 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The mass spectrometric behaviour of four macrocyclic, one macrobicyclic and one macroacyclic Schiff bases, obtained by one-step multiple condensation reactions of 2,6-diformyl-4-methylpropane, 1,3-diamino- 2,2-dimethylpropene, 1,5-diamino-3-oxapentane or tris-(2-aminoethyl) amine under fast-atom bombardment conditions, was studied in detail with the aid of mass-analyzed ion kinetic energy spectrometry. The mass spectrometric behaviour of a mononuclear macrobicy La(III) complex is also described.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The keV Cs+ liquid secondary-ion mass spectrometry (LSIMS) and 252Cf-plasma desorption (PD) mass spectra of recombinant proteins in the 10-25 kDa mass range are compared. Both techniques showed comparable mass accuracy and sensitivity, and in the case of LSIMS, remarkably short analysis time. Analysis by the PD/nitrocellulose method demonstrated slightly higher sensitivity and relativity lower dependence on the salt and buffer content of the protein sample.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: During sequence determination of a structural protein from the cuticle of the migratory locust, Locusta migratoria, a discrepancy was found between the molecular weight calculated from the sequence data (15 323) and that estimated by SDS-gel electrophoresis (21 600). The protein contains several repeated sequences, and the discrepancy might indicate that part of the sequence was missing or that the protein contained a large prosthetic group. The molecular weight of the protein was determined by 127I-plasma desorption mass spectrometry to be 15 329±50 which confirms the sequence data and shows the molecular weight determination based on SDS-electrophoresis to be too high.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 27 (1992), S. 231-239 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The mass spectrometric behaviour of four macroacyclic and five macrocyclic Schiff bases using two ionization methods (electron impact and fast atom bombardment) was studied in detail with the aid of mass-analysed ion kinetic energy (MIKE) spectrometry. It was possible to propose a common electron impact-induced decomposition pattern for the acyclic compounds, whereas for the cyclic compounds, analysed by fast atom bombardment, peculiar fragmentation routes occurred, which were strongly dependent on the macrocyclic structure and on the different side-chains.
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...