ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2019-07-13
    Description: The Johnson Space Center Water and Food Analytical Laboratory (WAFAL) performed detailed ground-based analyses of archival water samples for verification of the chemical quality of the International Space Station (ISS) potable water supplies for Expeditions 21 through 25. Over a 14-month period the Space Shuttle visited the ISS on four occasions to complete construction and deliver supplies. The onboard supplies of potable water available for consumption by the Expeditions 21 to 25 crews consisted of Russian ground-supplied potable water, Russian potable water regenerated from humidity condensate, and US potable water recovered from urine distillate and condensate. Chemical archival water samples that were collected with U.S. hardware during Expeditions 21 to 25 were returned on Shuttle flights STS-129 (ULF3), STS-130 (20A), STS-131 (19A), and STS-132 (ULF4), as well as on Soyuz flights 19-23. This paper reports the analytical results for these returned potable water archival samples and their compliance with ISS water quality standards.
    Keywords: Aeronautics (General)
    Type: JSC-CN-24006 , 41st International Conference on Environmental Systems; Jul 17, 2011 - Jul 21, 2011; Portland, OR; United States
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-07-13
    Description: In September 2010, analysis of ISS potable water samples was undertaken to determine the contaminant(s) responsible for a rise of total organic carbon (TOC) in the Water Processor Assembly (WPA) product water. As analysis of the routine target list of organic compounds did not reveal the contaminant, efforts to look for unknown compounds were initiated, resulting in discovery of an unknown peak in the gas chromatography/mass spectrometry (GC/MS) analysis for glycols. A mass spectrum of the contaminant was then generated by concentrating one of the samples and analyzing it by GC/MS in full-scan mode. Although a computer match of the compound identity could not be obtained with the instrument database, a search with a more up-to-date mass spectral library yielded a good match with dimethylsilanediol (DMSD). Inductively coupled plasma/mass spectrometry (ICP/MS) analyses showed abnormally high silicon levels in the samples, confirming that the unknown compound(s) contained silicon. DMSD was then synthesized to confirm the identification and provide a standard to develop a calibration curve. Further confirmation was provided by external direct analysis in real time time of flight (DART TOF) mass spectrometry. To routinely test for DMSD in the future, a quantitative method was needed. A preliminary GC/MS method was developed and archived samples from various locations on ISS were analyzed to determine the extent of the contamination and provide data for troubleshooting. This paper describes these events in more detail as well as problems encountered in routine GC/MS analyses and the subsequent development of high performance liquid chromatography and LC/MS/MS methods for measuring DMSD.
    Keywords: Aeronautics (General)
    Type: JSC-CN-24009 , 41st futemational Conference on Environmental Systems; Jul 17, 2011 - Jul 21, 2011; Portland, OR; United States
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...