ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2023-06-21
    Description: The Gravity Recovery and Climate Experiment Follow-On (GRACE-FO) mission carries magnetometers that are dedicated to enhance the satellite’s navigation. After appropriate calibration and characterisation of artificial magnetic disturbances, these observations are valuable assets to characterise the natural variability of Earth’s magnetic field. We describe the data pre-processing, the calibration, and characterisation strategy against a high-precision magnetic field model applied to the GRACE-FO magnetic data. During times of geomagnetic quiet conditions, the mean residual to the magnetic model is around 1 nT with standard deviations below 10 nT. The mean difference to data of ESA’s Swarm mission, which is dedicated to monitor the Earth’s magnetic field, is mainly within ± 10 nT during conjunctions. The performance of GRACE-FO magnetic data is further discussed on selected scientific examples. During a magnetic storm event in August 2018, GRACE-FO reveals the local time dependence of the magnetospheric ring current signature, which is in good agreement with results from a network of ground magnetic observations. Also, derived field-aligned currents (FACs) are applied to monitor auroral FACs that compare well in amplitude and statistical behaviour for local time, hemisphere, and solar wind conditions to approved earlier findings from other missions including Swarm. On a case event, it is demonstrated that the dual-satellite constellation of GRACE-FO is most suitable to derive the persistence of auroral FACs with scale lengths of 180 km or longer. Due to a relatively larger noise level compared to dedicated magnetic missions, GRACE-FO is especially suitable for high-amplitude event studies. However, GRACE-FO is also sensitive to ionospheric signatures even below the noise level within statistical approaches. The combination with data of dedicated magnetic field missions and other missions carrying non-dedicated magnetometers greatly enhances related scientific perspectives.
    Description: European Space Agency (FR)
    Description: HEIBRIDS
    Description: Projekt DEAL
    Description: ftp://isdcftp.gfz-potsdam.de/grace-fo/MAGNETIC_FIELD
    Keywords: ddc:538.7 ; Earth’s magnetic field ; Geomagnetism ; Ionospheric currents ; Magnetospheric ring current ; Satellite-based magnetometers ; Platform magnetometers ; GRACE-FO
    Language: English
    Type: doc-type:article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2024-04-01
    Description: This open access book offers essential information on values-based practice (VBP): the clinical skills involved, teamwork and person-centered care, links between values and evidence, and the importance of partnerships in shared decision-making. Different cultures have different values; for example, partnership in decision-making looks very different, from the highly individualized perspective of European and North American cultures to the collective and family-oriented perspectives common in South East Asia. In turn, African cultures offer yet another perspective, one that falls between these two extremes (called batho pele). The book will benefit everyone concerned with the practical challenges of delivering mental health services. Accordingly, all contributions are developed on the basis of case vignettes, and cover a range of situations in which values underlie tensions or uncertainties regarding how to proceed in clinical practice. Examples include the patient’s autonomy and best interest, the physician’s commitment to establishing high standards of clinical governance, clinical versus community best interest, institutional versus clinical interests, patients insisting on medically unsound but legal treatments etc. Thus far, VBP publications have mainly dealt with clinical scenarios involving individual values (of clinicians and patients). Our objective with this book is to develop a model of VBP that is culturally much broader in scope. As such, it offers a vital resource for mental health stakeholders in an increasingly inter-connected world. It also offers opportunities for cross-learning in values-based practice between cultures with very different clinical care traditions.
    Keywords: Psychiatry ; Psychology, general ; Ethics ; Behavioral Sciences and Psychology ; Moral Philosophy and Applied Ethics ; Assessment and diagnosis ; Evidence based practice ; Culture ; Abuse of psychiatry ; Medical ethics ; Medical law ; Psychosis ; Spirituality ; Involuntary treatment ; Insanity defence ; Medical education ; open access ; Psychology ; Ethics & moral philosophy ; thema EDItEUR::M Medicine and Nursing::MK Medical specialties, branches of medicine::MKL Psychiatry ; thema EDItEUR::J Society and Social Sciences::JM Psychology ; thema EDItEUR::Q Philosophy and Religion::QD Philosophy::QDT Topics in philosophy::QDTQ Ethics and moral philosophy
    Language: English
    Format: image/jpeg
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Atomic emission and MS detection ; Solid-phase extraction ; Aqueous samples
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A procedure is described for the (non-target) screening of hetero-atom-containing compounds in tap and waste water by correlating data obtained by gas chromatography (GC) using atomic emission (AED) and mass selective (MS) detection. Solid-phase extraction (SPE) was coupled on-line to both GC systems to enable the determination of microcontaminants at the 0.02–1 μg L−1 level in 7–50 mL of aqueous sample. The screening was limited to compounds present in at least one heteroatom-selective GC-AED trace above a predetermined concentration level. These compounds were identified by their partial formulae (AED) and the corresponding mass spectra, which were obtained from the GC-MS chromatogram via the retention index concept. The potential of the approach was demonstrated by the identification of target compounds as well as all unknowns present in tap and waste water above the predetermined threshold of 0.05 μg L−1 (tap water) or 0.5 μg L−1 (waste water).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Atomic emission detection ; Aqueous samples ; Solid-phase extraction ; Organophosphorus pesticides
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An on-line, solid-phase extraction gas chromatography atomic-emission detection (SPE-GC-AED) system has been set up using an on-column interface to transfer 100 μl of desorbing solvent to the GC part of the system. Analytical characteristics such as recovery, precision and linearity of calibration plots were comparable with those of the off-line combination of SPE-GC-AED using organophosphorus pesticides as test compounds. The fully on-line set-up causes a marked improvement in detection because of the quantitative transfer of the analytes from the SPE module to the GC: detection limits are as low as 5–20 ng l−1 for the analysis of 10 ml raw and spiked surface water samples using the phosphorus channel. Detection levels can be further enhanced by processing up to 100 ml samples. The integrated analytical system is robust. The potential of the on-line set up has been demonstrated for the analysis of surface water and waste water.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Urea herbicides ; Catalytic hydrolysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method is described for the rapid catalytic hydrolysis of phenylurea herbicides on silica gel at elevated temperatures. After derivatisation of the anilines produced with heptafluorobutyric acid anhydride final analysis is done on a gas chromatograph equipped with an electroncapture detector. Detection limits are in the 1–5 picogram range. The method has successfully been applied to residue analysis of water samples at the 1 ppb level. The determination of free anilines present in water samples and the potential of various techniques to be used to discriminate between free anilines and parent herbicides are also discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Headspace sampling ; PTV-System ; Ethephon in drinking water
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An indirect GC method is described for the determination of Ethephon in drinking water on the basis of the headspace analysis of the ethylene formed from Ethephon. In order to reach the necessary detection limit, the entire volume of the static headspace distribution is transferred into a cold injection system (CIS). There, the ethylene is adsorbed on Carbosieve SIII at 10°C and, subsequently, desorbed at 300 °C. The water vapour included in the headspace is completely eliminated through the splitting system. By means of this technique, a detection limit of 0.05 μg/l water was reached.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Chemiluminescence detection ; Phosphine derivatives ; Headspace analysis ; Fluorine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Phosphine, alkylated phosphines and monophosphinate esters are detected with high sensitivity in capillary gas chromatography (GC) by their chemiluminescent reactions with molecular fluorine. Detection limits are estimated to be 1.3 pg, 0.5 pg, 8 pg, and 17 pg for phosphine, trimethyl phosphine, trimethyl phosphinate ester, and triethyl phosphine, respectively. As found earlier with alkylated sulfur, selenium and tellurium compounds, the detector exhibits a linear response. For triethyl phosphine, a linear range of greater than three orders of magnitude was demonstrated. Emission spectra were obtained for the trimethyl phosphine and triethyl phosphine systems. Chemiluminescence emitters include electronically excited HCF, vibrationally excited HF, and an unknown species in the trimethyl phosphine system. Banded emission from vibrationally excited HF and a broad continuum were observed for both trimethyl phosphine and triethyl phosphine; however, HCF emission was observed only for TMP. Under the conditions employed, the principal emitter is HCF for trimethyl phosphine and HF and the unknown emitter for triethyl phosphine. This detector may have important applications in investigations of the biogeochemical cycling of phosphorus.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Supercritical fluid extraction ; GC detectors ; Purity of gases
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The usefulness of several grades of carbon dioxide for online supercritical fluid extraction/capillary gas chromatography has been studied. If trace-level work has to be performed, no single grade can be recommended for all modes of detection studied. Good-quality carbon dioxide is available for use with flame ionization and thermionic detectors. With electron-capture detection, however, distinct problems still exist.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Phosphine ; Flame photometric detection ; Anaerobic bacteria
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A gas chromatographic method is presented which distinguishes phosphine from hydrogen sulfide and other possible headspace gases of anaerobic microbial cultures. In anaerobic cultures spiked with phosphine, this gas is recovered in the liquid and gaseous phase down to 10 pg per ml of gas or liquid. No biogenically produced phosphine was found. Phosphine in amounts as small as 30 ng per 1 can be stored for several days in glass bottles covered with rubber septa, filled with nitrogen, in the presence or absence of water or of an anaerobic bacterial culture. Due to the selectivity of the detector and the retention characteristics of the porous layer open tubular polymer column alkanes, alkenes and organosulfur compounds routinely found in anaerobic bacterial headspaces do not interfere with the analytical quantification of phosphine.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1612-1112
    Keywords: Solid-phase extraction ; Gas chromatography ; Ion trap tandem mass spectrometry ; Water samples ; Environmental analysis ; Pesticides ; Bromide ; Nitrite
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary On-line solid-phase extraction-gas chromatographyion-trap tandem mass spectrometry (SPE-GC-MS/MS) has been used for the trace-level determination of polar and apolar pesticides. The SPE-GC interface, an Autoloop 2000, was operated at an injection temperature of 90°C which permitted the determination of thermolabile pesticides such as carbofuran and carbaryl. Rectilinear calibration curves were obtained for the analytes tested over a range of 0.1–500 ng L−1, using a sample volume of 10–100 mL for enrichment on an SPE cartridge packed with styrene-divinylbenzene copolymer. The detection limits for the pesticides were in the 0.01–4 ng L−1 range. For a number of pesticides acceptable tandem mass spectra were obtained at levels as low as 0.1 ng L−1 level in real-life water samples. As a demonstration of the applicability of this technique for inorganic anions, bromide and nitrite were converted into 4-bromoacetanilide and 2-phenylphenol, respectively. The reaction products were pooled and subjected to simultaneous analysis by the present method using full-scan mass spectrometric detection. The detection limits were 0.3 and 2 ng L−1, respectively.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...