ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • INSTRUMENTATION AND PHOTOGRAPHY  (3)
  • ATOMIC AND MOLECULAR PHYSICS  (1)
Collection
Keywords
Years
  • 1
    Publication Date: 2019-06-28
    Description: It is pointed out that detectors of the energy loss of penetrating charged particles are widely used for particle identification. These measurements are hampered, however, by fluctuations in the amount of energy deposited within the detector. It is shown that this limitation can be overcome with a new nuclear track detector, CR-39(DOP), and that the charge resolution of this detector exceeds that of any other, including semiconductor diodes.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Nature; 293; Oct. 15
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-06-27
    Description: The response of Pilot 425 to heavy ions with energies less than 600 MeV/amu beta approximately 0.8 is examined both theoretically and experimentally. Measurements are presented from an experiment which employed a Ne-20 beam at many energies below 575 MeV/amu. The signal is assumed to come from three sources: (1) Cerenkov light from the heavy ion, (2) Cerenkov light from secondary electrons, and (3) scintillation of the radiator. It is found that the effective index of refraction is 1.518 and that scintillation is present at a level of approximately 2.7 percent of the Cerenkov signal for beta = 1 for Ne-20. The first of these values differs from values previously quoted in the literature.
    Keywords: ATOMIC AND MOLECULAR PHYSICS
    Type: NASA-CR-146797
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-07-13
    Description: The sonic spark chamber provides an attractive high resolution hodoscope for low flux cosmic ray experiments. Spark position is determined by measurement of the time of flight of the sonic shock front from the spark position to a number of piezoelectric transducers placed at the periphery of the chamber. For each spark, four quantities must be determined: the spark coordinates, the sound velocity, and the spark 'size'. By over-determining the four parameters, high accuracy is possible. With eight sonic transducers, air-gap spark positions were measured with an error of less than 100 microns everywhere over a 1 sq m region.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: International Cosmic Ray Conference; Aug 15, 1975 - Aug 29, 1975; Munich
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-07-12
    Description: Excellent spatial resolution (34 microns) has been obtained using dimethylether, (CH3)2O at 1 atm in a small drift tube detector. This is better by at least a factor of 2 compared to previous work (about 80 microns) with a conventional gas (a 50-50 argon-ethane mixture) in the same detector. The Lorentz angle and the gas amplification have been measured over a wide range of electric and magnetic fields.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Nuclear Instruments and Methods in Physics Research, Section A - Accelerators, Spectrometers, Detectors, and Associated Equipment (ISSN 0168-9002); A287; 439-446
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...