Summary An indirect GC method is described for the determination of Ethephon in drinking water on the basis of the headspace analysis of the ethylene formed from Ethephon. In order to reach the necessary detection limit, the entire volume of the static headspace distribution is transferred into a cold injection system (CIS). There, the ethylene is adsorbed on Carbosieve SIII at 10°C and, subsequently, desorbed at 300 °C. The water vapour included in the headspace is completely eliminated through the splitting system. By means of this technique, a detection limit of 0.05 μg/l water was reached.