ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • ABU Dam  (1)
  • Canopy structure  (1)
  • Lolium perene  (1)
  • Zaria Dam  (1)
  • 1
    ISSN: 0378-4290
    Keywords: Canopy structure ; Extinction coefficient ; Radiation-use efficiency ; Triticum ; Wheat
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1572-9680
    Keywords: water balance ; Pinus radiata ; Lolium perene ; Medicago sativa ; Trifolium spp ; rainfall interception ; competition
    Source: Springer Online Journal Archives 1860-2000
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: Abstract In this study we determined soil moisture storage, evapotranspiration (ET) and light interception in an agroforestry trial consisting of pine trees grown over (1) control (bare ground), (2) ryegrass/clovers (Lolium perene/Trifolium spp.), (3) lucerne (Medicago sativa), and (4) ryegrass only during the third growing season between 1992 and 1993. The results show that: 1. In the period when rainfall was frequent and exceeded the evaporative demand (Epot), ET and depletion of soil moisture were not affected by the ground cover treatments. During summer when rainfall was less frequent, but with moisture readily available in the soil profile, ET was associated with plant canopy, and was significantly higher for the pasture ground covers than for the control. Therefore, the more rapid growth by lucerne caused higher ET in this ground cover than in the ryegrass/clovers ground cover in which the pasture was slow growing. At the end of the study period, total ET was in the following order: lucerne (757 mm) 〉 ryegrass/clovers (729 mm) 〉 Control (618 mm). 2. ET was dominated by pasture transpiration (Ep) during most of the growing season, but by tree transpiration (Et) in winter when large parts of the pasture canopy was shaded. Ep was always at least 16% higher for lucerne than for ryegrass/clovers species as a result of a greater radiation intercepted by the former. 3. Fraction of incoming radiation intercepted by the tree crowns was in the following order: control 〉 ryegrass 〉 ryegrass/clovers 〉 lucerne. At the end of the one-year period, fraction of intercepted radiation was 140% greater for control than for lucerne ground cover. 4. The control produced the largest tree crowns, which were almost twice the tree crowns in the lucerne ground cover which produced the smallest trees. Accordingly, the trees in the control intercepted more radiation and rainfall, with the former being lost to evaporation, than the trees in the pasture. 5. The fractions of radiation intercepted and ET accounted for by the trees and pastures were associated with the proportion of the plot area they occupied.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    facet.materialart.
    Unknown
    Fisheries Society of Nigeria | Lagos (Nigeria)
    In:  http://aquaticcommons.org/id/eprint/23440 | 19325 | 2018-05-02 08:25:12 | 23440 | Fisheries Society of Nigeria
    Publication Date: 2021-07-14
    Description: The physical and chemical parameters of ABU Dam and Zaria Dam were carried out between September and October 2009. The results obtained in the two water bodies were temperature 27.7 0C, pH (7.5 and 7.3), dissolved oxygen (5.8 mg/l and 5.0 mg/l), biochemical oxygen demand (1.74 mg/l and 2. 16 mg/l), alkalinity (58 mg CaC03/l and 49 mgCaCO3/l) P04-P (2.47 mg/l and 1.59 mg/l) NO3-N (3.67 mg/l and 3.47 mg/l), conductivity (54.70 ~ks-1 and 42.48 ~ks-1), total hydrocarbon (TH) (47.66 mg/l) and 48.00 mg/l) and total dissolved solids (32.68 mg/l and 25.35 mg/l) respectively. There was no significant difference in the mean values of the parameters (P〉0.05) except conductivity and total dissolved solids. The water bodies were found to be neutral with high conductivity. All the properties in the water bodies were in conformity with international standards both for drinking and aquatic life.
    Description: Includes:- 2 tables.;7 refs.
    Keywords: Chemistry ; Limnology ; Pollution ; Nigeria ; Zaria Dam ; Nigeria ; ABU Dam ; freshwater environment ; Physicochemical properties ; Pollution
    Repository Name: AquaDocs
    Type: conference_item , TRUE
    Format: application/pdf
    Format: application/pdf
    Format: 144-146
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...