ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2015-06-27
    Description: Author(s): Y. W. Windsor, M. Ramakrishnan, L. Rettig, A. Alberca, E. M. Bothschafter, U. Staub, K. Shimamoto, Y. Hu, T. Lippert, and C. W. Schneider We employ resonant soft x-ray diffraction to individually study the magnetic ordering of the Mn and the Tm sublattices in single-crystalline films of orthorhombic ( o − ) TmMn O 3 . The same magnetic ordering wave vector of ( 0 q 0 ) with q ≈ 0.46 is found for both ionic species, suggesting that the familiar ant… [Phys. Rev. B 91, 235144] Published Fri Jun 26, 2015
    Keywords: Electronic structure and strongly correlated systems
    Print ISSN: 1098-0121
    Electronic ISSN: 1095-3795
    Topics: Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0630
    Keywords: 81.60 ; 42.10 ; 82.50
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract The threshold fluence,F Th, of ablation of a triazeno-polymer was measured in the low fluence range for thin films using conventional UV-spectroscopy. It was found that there is a clearly definedF Th for 308 nm irradiation between 20 and 25 mJ cm−2. In the case of 248 nm irradiation, a “threshold fluence range” between 16 and 32 MJ cm−2 was found. The ablation rate for both irradiation wavelengths depends on film-thickness. For the XeCl excimer-laser, the point at which the rate becomes independent of thickness was observed to lie at a value which did not correspond to the calculated laser penetration depth, whereas for the KrF laser the independence was not reached within the applied thickness range (up to 0.35 μm). Additional transmission measurements have been performed showing that the target transmission at 248 nm increases only slightly, whereas for 308 nm the transmission increases by a factor of approximately 4. This result shows that dynamic target absorption properties are very important for describing the ablation process. The results derived from the transmission studies and etch rates were analyzed theoretically with a two-level model of chromophore absorption. For 248 nm irradiation this model can describe the transmission behavior and the ablation rate. In the case of 308 nm irradiation, it was only possible to match one data set. A good agreement with the experimental transmission ratio does not match the ablation rate and vice versa.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...