ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1436-5073
    Keywords: 5-chlorosalicylidene-o-aminophenol ; indium determination ; spectro-fluorimetry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract A Spectrofluorimetric method for microdetermination of indium, based on the formation of a fluorescent 2∶1 (ligand:metal) complex between In (III) and 5-chlorosalicylidene-o-aminophenol at an apparent pH of 4.70 in an aqueous-ethanol medium (50% v/v ethanol) is proposed. The calibration graph is linear over the range 10.0–80.0 μg/l, the relative standard deviation 2.7% and the detection limit 1.5 μg/l. The method has been applied to the determination of indium in synthetic samples and natural waters.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-4994
    Keywords: Benomyl and morestan determination ; solid-phase spectrofluorimetry ; pesticides residues ; water analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract In this paper a new, sensitive, and simple method for simultaneous determination of pesticides morestan and benomyl at trace levels in waters is reported. Both chemicals, showing native fluorescence in solution at neutral medium, were fixed on C-18 silica gel at pH 1, giving a fluorescent system. The benomyl-morestan-silica gel system, after dry, was packed in a 1-mm silica cell and its synchronous fluorescence spectra were recorded at δλ=80 nm for determination of benomyl and δλ=25 nm for determination of morestan. Measurements of fluorescence were performed at λ1=289 nm and λ2=367 nm for benomyl and morestan analysis, respectively. The applicable concentration ranges were from 0.5 to 15.0 ng·ml−1 for benomyl and from 0.6 to 15.0 ng·ml−1 for morestan, with relative standard deviations of 1.2 and 1.5% for benomyl and morestan, respectively, being 0.15 and 0.18 ng·ml−1 its respective detection limits. The method was applied to the simultaneous determination of residues of both pesticides in water of different provenances.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...