ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • INSTRUMENTATION AND PHOTOGRAPHY  (4)
  • 3-D Reconstruction  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Cell & tissue research 204 (1979), S. 343-354 
    ISSN: 1432-0878
    Keywords: Hypothalamo-pituitary afferents ; Vasopressin ; Somatostatin ; 3-D Reconstruction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary A three-dimensional reconstruction of the rat's hypothalamo-neurohypophysial system, depicting the neurons that project to the neurointermediate lobe of the pituitary, has been made by using retrograde transport of horseradish peroxidase injected into the neuro-intermediate lobe and by using immunocytochemistry with antisera to vasopressin and somatostatin. The overall picture illustrates the neurons situated in the walls of a pair of ill-defined cone-shaped tunnels, the apices pointing anteriorly. Among the neuronal aggregates in the tunnel wall two, the paraventricular and forniceal nuclei, appear similar in shape but clearly separated by a gap of at least 150 μm. Many of the vasopressin-positive neurons lie in the same nuclear aggregates with two notable exceptions: the suprachiasmatic nucleus contains many vasopressin-positive cells but does not project to the pituitary, and the forniceal aggregate, which does project to the pituitary, contains no vasopressin-positive cells. Somatostatin-positive cells are situated close to the third ventricle, and their size is intermediate between parvocellular and magnocellular. Cell counts show only half the cells in the system lying in the supraoptic and paraventricular nuclei, the rest being in “accessory nuclei”.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-06-28
    Description: It is pointed out that detectors of the energy loss of penetrating charged particles are widely used for particle identification. These measurements are hampered, however, by fluctuations in the amount of energy deposited within the detector. It is shown that this limitation can be overcome with a new nuclear track detector, CR-39(DOP), and that the charge resolution of this detector exceeds that of any other, including semiconductor diodes.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Nature; 293; Oct. 15
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-07-13
    Description: The sonic spark chamber provides an attractive high resolution hodoscope for low flux cosmic ray experiments. Spark position is determined by measurement of the time of flight of the sonic shock front from the spark position to a number of piezoelectric transducers placed at the periphery of the chamber. For each spark, four quantities must be determined: the spark coordinates, the sound velocity, and the spark 'size'. By over-determining the four parameters, high accuracy is possible. With eight sonic transducers, air-gap spark positions were measured with an error of less than 100 microns everywhere over a 1 sq m region.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: International Cosmic Ray Conference; Aug 15, 1975 - Aug 29, 1975; Munich
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2019-07-13
    Description: The striking clarity and high contrast of the mouths of tracks etched in CR-39 plastic detectors allow automatic measurement of track parameters to be made with simple image-recognition equipment. Using a commercially available Vidicon camera system with a microprocessor-controlled digitizer, resolution for normally incident C-12 and N-14 ions at 32 MeV/amu equivalent to a 14sigma separation of adjacent charges was demonstrated.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: International Cosmic Ray Conference; Aug 06, 1979 - Aug 18, 1979; Kyoto; Japan
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-07-13
    Description: The sensitivity of CR-39 is a strong function of catalyst concentration during its polymerization. Normal CR-39 will detect vertically incident particles with Z/beta as low as 10. An extrapolation suggests that CR-39 with a high catalyst concentration and sensitivity to within approximate 5% can be made by a suitable choice of cure cycle and mold material. CR-39 is less sensitive than Lexan to thermal annealing of tracks but cannot tolerate background radiation levels greater than a few Mrad.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: International Cosmic Ray Conference; Aug 06, 1979 - Aug 18, 1979; Kyoto; Japan
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...