ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chemistry  (8)
  • 21.60.Ev  (1)
  • Electrochemistry  (1)
  • Extravascular smooth muscle cells  (1)
Collection
Keywords
Publisher
  • 1
    ISSN: 1434-601X
    Keywords: 21.10.Re ; 21.60.Ev ; 23.20.Lv ; 27.90. + b
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We report on a measurement of the lifetime of the 1414 keV state in232Th by the Doppler-shift recoil-distance method. This 4+ state shows all characteristics of a nearly-harmonic two-phononγ-vibrational excitation. The result for the B(E2) value obtained from the lifetime,τ=3.2 ± 0.7 ps, is in agreement with an earlier estimate of the collectivity from Coulomb-excitation yields and supports the interpretation of the 1414 keV state as a two-phononγ-vibrational excitation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0878
    Keywords: Key words: Elastic fibres ; Placental stem villi ; Extravascular smooth muscle cells ; Adhesion plaques ; Talin immunoreactivity ; Human
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract. The stroma of human placental stem villi is believed to consist only of reticular and collagen fibres. In the present study we were able to show for the first time by light (orcein staining) and electron microscopy large amounts of elastic fibres in the stem villous stroma. Electron microscopically, homogeneous elastin was found alone or in association with microfibrils. In addition, microfibrils were observed forming long bands. These three structures, generally known to form elastic connective tissue, were seen in close connection with placental extravascular smooth muscle cells, which belong to the perivascular contractile sheath (PVCS) of stem villi. Elastin was associated with these smooth muscle cells and connected to collagen fibres via microfibrils. Collagen fibres were additionally interconnected by spike-like structures. Extravascular smooth muscle cells revealed numerous adhesion plaques which occupied conspicuously long cytoplasmic faces of the plasma membrane. In cryostat sections, immunoreactivity of talin, an attachment protein of adhesion plaques linking intracellular α-actin filaments with extracellular fibronectin, was detected in extravascular and vascular (media) smooth muscle cells. The arrangement of placental extravascular smooth muscle cells, elastic and collagen fibres suggests a functional myofibroelastic unit within the PVCS, which surrounds the large foetal blood vessels possibly contributing to elasticity and supporting tensile and/or contracting forces within the stem villi.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 21 (1970), S. 703-711 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: The instationary corrosion of passive iron in acid solutionThe corrosion rate of the passive iron, i.e. the dissolution rate of the passivating layer, in 1 n H2SO4 is investigated, with the layer thickness being increased and decreased, respectively (non-stationary conditions). The corrosion rate is determined chemical-analytically as well as coulometrically on the basis of galvanostatic measurements. Both methods yield the same result.The corrosion current density, iK, increases as the formation current density, iS, of the layer increases, and decreases the more below the stationary corrosion value, iK, the higher the layer reduction current density (iS 〈0) is. iK and iS, are independent of the electrode Potential of the passive iron electrode, similar to the behaviour of the stationary value, iK,0. This independence is explained by the semiconductor properties of the passivating oxide (γ-Fe2O3).There is an unique correlation between iK and iSs which can be explained also theoretically by a variable overvoltage at the phase boundary oxidelectrolyte.The kinetics of the corrosion and of the layer formation is evaluated from the values of the apparent charge transfer coefficients by referring to the pH dependence of the stationary corrosion.
    Notes: Die Korrosionsgeschwindigkeit des passiven Eisens, also die Auflösungsgeschwindigkeit der Passivschicht, wird in 1 n H2SO4 unter Bedingungen untersucht, bei denen die Schicht aur- bzw. abgebaut wird (instationärer Zustand). Die Korrosionsgeschwindigkeit wird sowohl chemisch-analytisch als auch coulometrisch aufgrund galvanostatischer Potentialmessungen ermittelt. Beide Methoden lie fern das gleiche Ergebnis.Die Stromdichte iK für die Korrosion steigt mit wachsender Stromdichte iS für den Schichtaufbau und sinkt andererseits um so mehr unter dem Wert iK,0 der stationären Korrosion, je größer die Schicht Abbaustromdichte (iK〈0) ist. iK und iS sind unabhängig vom Elektrodenpotential der passiven Eisenelektrode, so wie es früher beim stationären Wert iK,0 festgestellt wurde. Diese Unabhängigkeit wird durch Halbleitereigenschaften des Passivoxids (γ-Fe2O3) erklärt.Zwischen iK und iS besteht ein eindeutiger Zusammenhang, der auch theoretisch über eine veränderliche Überspannung an der Phasengrenze Passivoxid/Elektrolyt erklärt werden kann.Die Kinetik der Korrosion und der Schichtbildung wird unter Zuhilfenahme der piH der stationären Korrosion aus den Werten der scheinbaren Durchtrittsfaktoren ermittelt.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für die chemische Industrie 73 (1961), S. 277-290 
    ISSN: 0044-8249
    Keywords: Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In einem Überblick werden die kathodische Wasserstoffüberspannung und die anodische Sauerstoffüberspannung getrennt voneinander behandelt. Als theoretische Grundlage werden bei der Wasserstoffüberspannung der Volmer-Tafel- und der Volmer-Heyrowsky-Mechanismus diskutiert. Bei der Sauerstoffüberspannung werden die Theorien in zwei Gruppen aufgeteilt. In der einen Gruppe ist eine oxydische Oberflächenschicht unmittelbar am Mechanismus beteiligt, während bei der anderen Gruppe die elektrochemische Reaktion nur an einer oxydbedeckten Oberfläche ohne Beteiligung der dort befindlichen O-Atome abläft. Die Abhängigkeit von der Stromdichte, vom Elektrodenmaterial, vom pH, von der Zeit, vom Fremdionenzusatz und von der Adsorption von Fremdstoffen werden für die Wasserstoff- und Sauerstoffentwicklung experimentell und theoretisch behandelt.
    Additional Material: 26 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für die chemische Industrie 74 (1962), S. 442-442 
    ISSN: 0044-8249
    Keywords: Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für die chemische Industrie 75 (1963), S. 218-218 
    ISSN: 0044-8249
    Keywords: Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für die chemische Industrie 48 (1935), S. 92-95 
    ISSN: 0044-8249
    Keywords: Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0009-286X
    Keywords: Chemistry ; Industrial Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Nach Besprechung der Problematik der Elektrodenkinetik werden die Grundzüge der Theorie der Überspannung diskutiert. Für das Auftreten der Überspannung sind bei Redoxprozessen drei Arten der Hemmung, die der Diffusion, die des Elektronendurchtritts durch die elektrolytische Doppelschicht und die einer vor- oder nachgelagerten homogenen oder heterogenen chemischen Reaktion verantwortlich. Aus der Konzentrationsabhängigkeit der Durchtrittsüberspannung bzw. der Austauschstromdichte können anodische und kathodische elektrochemische Reaktionsordnungen bestimmt werden. Mit Hilfe dieser Größen kann die Durchtrittsreaktion, also der Ladungsübergang an der Phasengrenze, ermittelt werden. Aus der Konzentrationsabhängigkeit der Reaktionsüberspannung bzw. der Reaktionsgrenzstromdichten können chemische Reaktionsordnungen bestimmt werden, die die Erfassung der vor- bzw. nachgelagerten chemischen Reaktionen erlauben. - Für die Messungen der Überspannungsanteile wird die Ermittlung der Stromdichte-Überspannungskurven mittels galvanostatischer und potentiostatischer stationärer Methoden und Impulsmethoden behandelt. Die Ermittlung des ohmschen Spannungsabfalls im Elektrolyten wird besprochen. Als weitere Methode wird die Messung der Elektrodenimpedanz als Funktion der Frequenz diskutiert. Abschließend wird die Ermittlung von Zwischenprodukten mit Hilfe der rotierenden Scheiben- und Ringelektrode, aus Transitionszeitmessungen bei Doppelimpulsen und mit der Elektronen-Spin-Resonanz-Methode behandelt.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0009-286X
    Keywords: Chemistry ; Industrial Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Technische Anodenmaterialien müssen aus Gründen der Haltbarkeit eine geringe Korrosion und aus energetischen Gründen eine kleine Überspannung des Anodenprozesses aufweisen. Die maximale Korrosion im aktiven Zustand wird mit und ohne Komplexbildung auf der Grundlage diskutiert, daß Diffusionsvorgänge begrenzend sind. Hierbei wird auch die Bildung von porösen Deckschichten bei schwerer löslichen Korrosionsprodukten berücksichtigt. Die Korrosion im passiven Zustand wird als Eigenschaft der porenfreien Passivschicht an verschiedenen Beispielen behandelt und das Flade-Potential für den Übergang aktiv/passiv und dessen Eigenschaften diskutiert. Der Einfluß von pH-Wert und Komplexbildnern auf die passive Korrosion wird behandelt. - Anodenprozesse, hier also Redoxprozesse wie anodische Sauerstoffoder Chlor-Entwicklung, können an passiven Elektroden nur ablaufen, wenn die Passivschicht eine ausreichende Elektronenleitfähigkeit hat. An Aluminium, Titan und Tantal als Beispiel ist das nicht der Fall. Die Überspannung ist an passiven Anoden eine Eigenschaft der Passivschicht an der elektrolytseitigen Phasengrenze. - Halbleitermaterialien und Graphit werden als Anodenmaterialien gesondert diskutiert.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0570-0833
    Keywords: Anodes ; Electrochemistry ; Passivation ; Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Industrial anode materials should show small tendency to corrode in order to have a long life and, from energy considerations, should give low anodic overvoltages. The maximum corrosion in the active state in the presence and absence of complex formation is discussed of porous outer films of more difficulty soluble corrosion products. Corrosion in the passive state is treated as a property of the nonporous passive layer; several examples are presented, and the Flade potential for transitions from the active to the passive state and its properties are discussed. The influence of pH and complexing agents on passive corrosion is treated. Anode processes or, as treated here, redox processes such as the evolution of oxygen or chlorine can take place at passive electrodes only if the passive film has a sufficiently high electron conductivity. This is not the case with films on aluminum, titanium, and tantalum, for example. The overvoltage on passive anodes is a property of the passive film at the electrolyte side of the phase boundary. - Semiconducting materials and graphite as anode materials are discussed separately.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...