Publication Date:
2017-04-04
Description:
Italy is one of the most promising prone areas to study the CO2 behavior underground, the caprock integrity to
the CO2 leakage, mostly in presence of pervious/geochemically active faults, due to a wide availability of CO2 rich
reservoirs at a depth between 1 and 10 km, as highlighted by recent literature. These deep CO2 reservoirs generate at
least 200 leakage areas at surface throughout Italy which have been defined “Diffuse Degassing Structures” (DDS)
by INGV. These are widely studied by INGV institutionally by a long term convention with the Civil Protection
Department (DPC) with the aim to catalog, monitor and assess the Natural Gas Hazard (NGH, namely the
probability of an area to become a site of poisonous peri – volcanic gas exhalation from soils). More than 150
researcher of INGV are involved in monitoring areas affected by the CO2 presence underground and at surface, by
continuous monitoring on-line networks (around 40 stations throughout Italy, including the Etna area, Aeolian
Islands, Umbria region, Piemonte region, etc…) and discretely (9 groups of research were involved in the last years
to localize, define and monitor almost all the DDSs in Italy), by sampling and analyzing chemical and isotopic
compounds, useful to discriminate the origin, evolution and natural gas hazards of the examined DDS. In this paper,
we will discuss some DDS catalogued and studied by a Rome INGV Research Unit (UR 11) which focused its work
in Central Italy, throughout different DDS, also in relation to the diverse seismotectonic settings, to discover buried
faults as possible gas leakage pathways, mostly if they are “geochemically” activated. In particular we discuss,
among the discrete monitoring techniques exploited by INGV, soil gas surveying, which consists in a collection of
gas samples from the soil zone not saturated (dry zone) to measure the geogas gaseous species both in fluxes (CO2,
CH4, 222Rn) and in concentration (He, H2, H2S, helium, hydrogen, CO2, CH4, 222Rn), that permeate the soil pores.
The total CO2 flux budget was calculated as “baseline” degassing rate of these “CO2 analogues”. A good discrete
areal monitoring is prerequisite to design sound continuous monitoring network to monitor CO2 related parameters
in liquid/gas phases, to review the protocol of the Annex II of the European Directivity on CCS.
Description:
Published
Description:
2135-2142
Description:
2.4. TTC - Laboratori di geochimica dei fluidi
Description:
N/A or not JCR
Description:
reserved
Keywords:
Diffuse Degassing Structures
;
CO2 storage
;
05. General::05.08. Risk::05.08.01. Environmental risk
Repository Name:
Istituto Nazionale di Geofisica e Vulcanologia (INGV)
Type:
article
Permalink