ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Gas chromatography  (8)
  • Polymer and Materials Science  (5)
  • Supercritical fluid chromatography  (5)
  • Wiley-Blackwell  (17)
  • 1
    ISSN: 0887-624X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The synthesis and living cationic polymerization of 11-[(4-cyano-4′-biphenyl)oxy]-undecanyl vinyl ether (6-11) are described. The mesomorphic phase behavior of poly(6-11) with different degrees of polymerization was compared to that of 6-11 and of 11-[(4-cyano-4′-biphenyl) oxy] undecanyl ethyl ether (8-11) which is the model compound of the monomeric structural unit of poly(6-11). 6-11 displays a monotropic SA and a monotropic nematic mesophase while 8-11 an enantiotropic SA mesophase. Poly(6-11) with low degrees of polymerization exhibits an enantiotropic SA mesophase. Poly(6-8) with high degrees of polymerization displays an enantiotropic SX (i. e., an unidentified smectic phase) and an enantiotropic SC mesophase. These results demonstrate that the transformation of the nematic mesophase of the monomer into a smectic mesophase after polymerization, occurs at the level of monomeric structural unit.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 312-318 
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography ; Capillary column ; Column diameter ; Efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Fused silica capillary columns with internal diameters from 100 to 25 μm were coated with SE-54 and evaluated under supercritical fluid chromatographic conditions using carbon dioxide as mobile phase. Experimental results compared well with theoretical predictions. At ten times the optimum mobile phase velocity and for a capacity factor, k of 3, efficiencies of 2300 to 5600 plates m-1 were obtained for column diameters of 100 to 25 μm, respectively.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 329-332 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary columns ; Deactivation ; Polymethylhydrosiloxanes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 423-428 
    ISSN: 0935-6304
    Keywords: Capillary column ; Supercritical fluid chromatography ; Stationary phase film thickness ; Efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Fused-silica capillary columns with internal diameters of 50 μm were coated with 0.25 to 1.0 μm films of SE-54 and evaluated under supercritical fluid chromatographic conditions using carbon dioxide as mobile phase. Experimental results compared well with theoretical predictions. There was no significant difference in hmin or ūopt for film thicknesses from 0.25 to 1.0 μm over k = 1 to 5. At a film thickness of 1.0 μm, calculations indicate that approximately 10% resolution loss would be expected for solutes with k = 1.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 741-747 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary columns ; Deactivation ; Cyanopropylhydrosiloxanes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is described for surface deactivation and modification of fused silica capillary columns with a cyanopropyl-containing reagent. The deactivation procedure involved a dehydrocondensation reaction between a bis(cyanopropyl)methylhydropolysiloxane reagent and surface silanol groups at an optimum temperature of only 250°C. Actual critical surface tension measurements were made using the capillary rise method. Excellent deactivation for acidic and basic compounds at the low ng level, and wettability for nonpolar and polar polysiloxane stationary phases were obtained. A procedure was developed to remove acidic impurities that are present in polar stationary phases.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 319-321 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Supercritical fluid chromatography ; Small diameter capillary columns ; Static coating at elevated temperature ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 161-167 
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography ; Thermionic detection ; Nitrated polycyclic aromatic compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A thermionic detector was evaluated for capillary supercritical fluid chromatography of polar nitro-containing polycyclic aromatic compounds (nitro-PAC). Three modes of detector operation were studied. The best performance was obtained using a nitro-selective mode of detection. Although linearity was confined to a narrow range for a given source current, the sensitivity was excellent; 20 pg injected for p-nitrophenol gave a signal-to-noise ratio of 3. Conventional thermionic detection also produced good sensitivity; however, serious baseline drift was observed at high operating temperatures using density programming. A third mode, flame thermionic detection, was not acceptable because of low sensitivity. A number of nitro-PAC were successfully chromatographed using density programming at 101°C. Hydroxynitropyrenes, nitropyrene quinones, and 9-hydroxy-2-nitrofluorene, which could not be eluted in capillary gas chromatography, were successfully chromatographed here. Retention of these compounds increased sequentially on 50% n-octyl-, 5% phenyl-, and 25% biphenyl polysiloxane stationary phases, respectively. Stationary phase interactions appeared to be more a function of the polar functional groups on the aromatic rings than of the hydrocarbon character of the compounds. Solute solubility in the mobile phase and volatility were additional factors contributing to the elution of these molecules. Finally, these results were used to identify a number of nitro-PAC in a polar subfraction of a diesel particulate extract.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 193-207 
    ISSN: 0935-6304
    Keywords: Multidimensional chromatography ; Liquid chromatography ; Gas chromatography ; Gupercritical fluid chromatography ; Fuels ; Foodstuffs ; Environmental ; Biological ; Pharmaceutical ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Although coupled liquid chromatographygas chromatography (LC-GC) was first demonstrated ten years ago, only in the last few years has there been a sudden surge of interest in the technique. Approximately 70% of the total number of LC-GC applications have been published in the last two years (1987-88) alone. This review categorizes LC-GC publications into four main application areas: fossil fuels, foods, environmental samples, biologiical/pharmaceutical samples, and miscellaneous samples. Multidimensional separations carried out using other coupled-column chromatographic techniques (such as supercritical fluid chromatography (SFC) with GC, and on-line trace enrichment-GC) have also been included in this review.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 89-92 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Stationary phase ; Polysiloxane ; Autocrosslinkable ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Methyl-2-phenylethylpolysiloxane polymers have been synthesized for comparison with methylphenylpolysiloxane stationary phases for gas chromatography. The 50% 2-phenylethyl polysiloxane was found to be autocrosslinkable at 260°C without addition of free redical initiator. Although the selectivity of this phase appears to be similar to the 50% phenyl polysiloxane, its thermal stability is not as high.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Environmental tobacco smoke ; Sampling ; Tenax ; Nicotine, 3-Ethenylpyridine, Particulate nicotine ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A combined sampling and analysis technique for the determination of gas phase nicotine and 3-ethenylpyridine, and of particulate phase nicotine in environmental tobacco smoke with capillary gas chromatography is reported. The major advantage of the technique is that all of the collected particulate phase material is analyzed by thermal desorption of the collected material rather than by analysis of only a fraction of the sample extracted from the collection medium. A Teflon filter microtube is used to collect particulate phase nicotine. This microtube is follwed by a small Tenax sorbent bed to collect gas phase nicotine and 3-ethenylpyridine. After sampling, the Teflon filter is transferred to a clean glass tube and the tube becomes an insert for a modified packed column injector port where the material collected on the filter is heat desorbed to a cold capillary tubing trap. Gas phase nicotine and 3-ethenylpyridine are also transferred from the Tenax to the GC column by thermal desorption from the Tenax sorbent bed. Gas phase nicotine and 3-ethenylpyridine, and particulate phase nicotine are each determined by GC analysis of the desorbed material. Nicotine and 3-ethenylpyridine are quantitated by the use of external standards. This technique is straightforward and can be used for semi-real time determination of both gas and particulate phase compounds in environmental tobacco smoke. The results obtained by this technique compare well with those obtained by sampling with annular diffusion denuders.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...