ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Capillary columns  (6)
  • Supercritical fluid chromatography  (5)
  • Deactivation  (4)
  • Wiley-Blackwell  (14)
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 312-318 
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography ; Capillary column ; Column diameter ; Efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Fused silica capillary columns with internal diameters from 100 to 25 μm were coated with SE-54 and evaluated under supercritical fluid chromatographic conditions using carbon dioxide as mobile phase. Experimental results compared well with theoretical predictions. At ten times the optimum mobile phase velocity and for a capacity factor, k of 3, efficiencies of 2300 to 5600 plates m-1 were obtained for column diameters of 100 to 25 μm, respectively.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 329-332 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary columns ; Deactivation ; Polymethylhydrosiloxanes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 423-428 
    ISSN: 0935-6304
    Keywords: Capillary column ; Supercritical fluid chromatography ; Stationary phase film thickness ; Efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Fused-silica capillary columns with internal diameters of 50 μm were coated with 0.25 to 1.0 μm films of SE-54 and evaluated under supercritical fluid chromatographic conditions using carbon dioxide as mobile phase. Experimental results compared well with theoretical predictions. There was no significant difference in hmin or ūopt for film thicknesses from 0.25 to 1.0 μm over k = 1 to 5. At a film thickness of 1.0 μm, calculations indicate that approximately 10% resolution loss would be expected for solutes with k = 1.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 741-747 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary columns ; Deactivation ; Cyanopropylhydrosiloxanes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is described for surface deactivation and modification of fused silica capillary columns with a cyanopropyl-containing reagent. The deactivation procedure involved a dehydrocondensation reaction between a bis(cyanopropyl)methylhydropolysiloxane reagent and surface silanol groups at an optimum temperature of only 250°C. Actual critical surface tension measurements were made using the capillary rise method. Excellent deactivation for acidic and basic compounds at the low ng level, and wettability for nonpolar and polar polysiloxane stationary phases were obtained. A procedure was developed to remove acidic impurities that are present in polar stationary phases.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 319-321 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Supercritical fluid chromatography ; Small diameter capillary columns ; Static coating at elevated temperature ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 161-167 
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography ; Thermionic detection ; Nitrated polycyclic aromatic compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A thermionic detector was evaluated for capillary supercritical fluid chromatography of polar nitro-containing polycyclic aromatic compounds (nitro-PAC). Three modes of detector operation were studied. The best performance was obtained using a nitro-selective mode of detection. Although linearity was confined to a narrow range for a given source current, the sensitivity was excellent; 20 pg injected for p-nitrophenol gave a signal-to-noise ratio of 3. Conventional thermionic detection also produced good sensitivity; however, serious baseline drift was observed at high operating temperatures using density programming. A third mode, flame thermionic detection, was not acceptable because of low sensitivity. A number of nitro-PAC were successfully chromatographed using density programming at 101°C. Hydroxynitropyrenes, nitropyrene quinones, and 9-hydroxy-2-nitrofluorene, which could not be eluted in capillary gas chromatography, were successfully chromatographed here. Retention of these compounds increased sequentially on 50% n-octyl-, 5% phenyl-, and 25% biphenyl polysiloxane stationary phases, respectively. Stationary phase interactions appeared to be more a function of the polar functional groups on the aromatic rings than of the hydrocarbon character of the compounds. Solute solubility in the mobile phase and volatility were additional factors contributing to the elution of these molecules. Finally, these results were used to identify a number of nitro-PAC in a polar subfraction of a diesel particulate extract.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 113-118 
    ISSN: 0935-6304
    Keywords: Static coating ; Biphenyl polysiloxane ; Capillary columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Static coating of phenyl and biphenyl polysiloxane stationary phases on 50 μm i.d. open tubular capillaries was studied. The influence of coating solvents and coating temperatures on the viscosities and surface tensions of the polymer stationary phases and their coating solutions was determined. A measure of the Rayleigh instability paralled the observed coating efficiencies.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 10 (1987), S. 257-262 
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography, SFC ; Capillary columns ; Ammonia ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Instrumentation was assembled that allows the use of supercritical ammonia as mobile phase in capillary supercritical fluid chromatography. Several modifications of the typical chromatographic system were necessary, especially with respect to injection and detection. In addition, the stabilities of various polysiloxane stationary phases were studied. The chromatography of polarizable and polar basic materials was demonstrated using a nonpolar polysiloxane stationary phase.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 10 (1987), S. 128-136 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Coating of capillaries, static and dynamic ; Rayleigh instability ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The film of stationary phase on the wall of a capillary column and that of the phase solution during both static and dynamic coating is subject to Rayleigh instability, which is quite independent of so-called wettability. A theory is developed which shows that the logarithmic growth rate of Rayleigh instabilities is proportional to the surface tension and to the third power of the film thickness, and inversely to the viscosity and to the fourth power of the capillary diameter. Determination of the variation of the viscosities of stationary phase solutions with concentration in coating solvents, and the variation of the viscosities of neat stationary phases with temperature, both revealed that heating and/or diluting changed the viscosities of phases with π-electron-containing, groups much more than for polydimethylsiloxanes. Rayleigh instability is therefore more important during coating of phenyl-containing phases such as OV-17, and later during column operation. The efficiencies of capillary columns of different diameters coated with a number of phases under different conditions of temperature and coating rate, and then operated at different temperatures were in good agreement with the predictions of the theory.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 13-18 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Biphenyl polysiloxane ; Stationary phase ; Polarizable phase ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A crosslinkable biphenylmethylpolysiloxane stationary phase was synthesized for capillary column gas chromatography and compared with methyl, phenyl, and cyanopropyl polysiloxane stationary phases for the separation of isomeric polycyclic aromatic compounds. While the new phase gave similar separations of nonpolar isomers when compared to the nonpolar phases, separations of polar isomers were greatly improved because of the induced polarity of the biphenyl group of the stationary phase by the solute molecules. This polarizable stationary phase offers a unique selectivity which is not available in other stationary phases.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...