ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (5)
  • Supercritical fluid chromatography  (5)
  • Biphenyl polysiloxane  (2)
  • Wiley-Blackwell  (12)
  • 1
    ISSN: 0887-624X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The synthesis and living cationic polymerization of 11-[(4-cyano-4′-biphenyl)oxy]-undecanyl vinyl ether (6-11) are described. The mesomorphic phase behavior of poly(6-11) with different degrees of polymerization was compared to that of 6-11 and of 11-[(4-cyano-4′-biphenyl) oxy] undecanyl ethyl ether (8-11) which is the model compound of the monomeric structural unit of poly(6-11). 6-11 displays a monotropic SA and a monotropic nematic mesophase while 8-11 an enantiotropic SA mesophase. Poly(6-11) with low degrees of polymerization exhibits an enantiotropic SA mesophase. Poly(6-8) with high degrees of polymerization displays an enantiotropic SX (i. e., an unidentified smectic phase) and an enantiotropic SC mesophase. These results demonstrate that the transformation of the nematic mesophase of the monomer into a smectic mesophase after polymerization, occurs at the level of monomeric structural unit.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 312-318 
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography ; Capillary column ; Column diameter ; Efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Fused silica capillary columns with internal diameters from 100 to 25 μm were coated with SE-54 and evaluated under supercritical fluid chromatographic conditions using carbon dioxide as mobile phase. Experimental results compared well with theoretical predictions. At ten times the optimum mobile phase velocity and for a capacity factor, k of 3, efficiencies of 2300 to 5600 plates m-1 were obtained for column diameters of 100 to 25 μm, respectively.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 423-428 
    ISSN: 0935-6304
    Keywords: Capillary column ; Supercritical fluid chromatography ; Stationary phase film thickness ; Efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Fused-silica capillary columns with internal diameters of 50 μm were coated with 0.25 to 1.0 μm films of SE-54 and evaluated under supercritical fluid chromatographic conditions using carbon dioxide as mobile phase. Experimental results compared well with theoretical predictions. There was no significant difference in hmin or ūopt for film thicknesses from 0.25 to 1.0 μm over k = 1 to 5. At a film thickness of 1.0 μm, calculations indicate that approximately 10% resolution loss would be expected for solutes with k = 1.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 319-321 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Supercritical fluid chromatography ; Small diameter capillary columns ; Static coating at elevated temperature ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 161-167 
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography ; Thermionic detection ; Nitrated polycyclic aromatic compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A thermionic detector was evaluated for capillary supercritical fluid chromatography of polar nitro-containing polycyclic aromatic compounds (nitro-PAC). Three modes of detector operation were studied. The best performance was obtained using a nitro-selective mode of detection. Although linearity was confined to a narrow range for a given source current, the sensitivity was excellent; 20 pg injected for p-nitrophenol gave a signal-to-noise ratio of 3. Conventional thermionic detection also produced good sensitivity; however, serious baseline drift was observed at high operating temperatures using density programming. A third mode, flame thermionic detection, was not acceptable because of low sensitivity. A number of nitro-PAC were successfully chromatographed using density programming at 101°C. Hydroxynitropyrenes, nitropyrene quinones, and 9-hydroxy-2-nitrofluorene, which could not be eluted in capillary gas chromatography, were successfully chromatographed here. Retention of these compounds increased sequentially on 50% n-octyl-, 5% phenyl-, and 25% biphenyl polysiloxane stationary phases, respectively. Stationary phase interactions appeared to be more a function of the polar functional groups on the aromatic rings than of the hydrocarbon character of the compounds. Solute solubility in the mobile phase and volatility were additional factors contributing to the elution of these molecules. Finally, these results were used to identify a number of nitro-PAC in a polar subfraction of a diesel particulate extract.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 113-118 
    ISSN: 0935-6304
    Keywords: Static coating ; Biphenyl polysiloxane ; Capillary columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Static coating of phenyl and biphenyl polysiloxane stationary phases on 50 μm i.d. open tubular capillaries was studied. The influence of coating solvents and coating temperatures on the viscosities and surface tensions of the polymer stationary phases and their coating solutions was determined. A measure of the Rayleigh instability paralled the observed coating efficiencies.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 13-18 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Biphenyl polysiloxane ; Stationary phase ; Polarizable phase ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A crosslinkable biphenylmethylpolysiloxane stationary phase was synthesized for capillary column gas chromatography and compared with methyl, phenyl, and cyanopropyl polysiloxane stationary phases for the separation of isomeric polycyclic aromatic compounds. While the new phase gave similar separations of nonpolar isomers when compared to the nonpolar phases, separations of polar isomers were greatly improved because of the induced polarity of the biphenyl group of the stationary phase by the solute molecules. This polarizable stationary phase offers a unique selectivity which is not available in other stationary phases.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 652-656 
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography ; Capillary columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In cases where high efficiency is required to resolve complex mixtures of either thermally labile or nonvolatile organic compounds, capillary supercritical fluid chromatography may be the most desirable analytical method. While great strides in this new technology have been made over the last few years, several problem areas are requiring increased attention. These include sample introduction systems, pressure reduction at the end of the column, column stability in various supercritical mobile phases, and migration of polar solute molecules. This paper describes the state-of-the-art in capillary SFC with emphasis on the progress made and future needs in the solutions to these specific problems.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 35 (1997), S. 2835-2842 
    ISSN: 0887-6266
    Keywords: polymer blends ; random copolymer ; compatibilizer ; encapsulation ; coalescence ; Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: We investigate the compatibilizing performance of a random copolymer in the melt state, using transmission electron microscopy. Blends of polystyrene (PS) and poly(methyl methacrylate) (PMMA) are chosen as a model system, and a random copolymer of styrene and methyl methacrylate (SMMA) with 70 wt % styrene is used as a compatibilizer. From TEM photographs it is clear that SMMA moves to the interface between PS and PMMA domains during melt mixing, and forms encapsulating layers. However, the characteristic size of the dispersed phase increases gradually with annealing time for all blend systems studied. This demonstrates that the encapsulating layer of SMMA does not provide stability against static coalescence, which calls into question the effectiveness of random copolymers as practical compatibilizers. We interpret the encapsulation by random copolymers in terms of a simple model for ternary polymer blends. © 1997 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 35: 2835-2842, 1997
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 35 (1997), S. 2811-2823 
    ISSN: 0887-6266
    Keywords: diblock copolymer ; anisotropic modulus ; order-order transition ; triblock copolymer ; Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: A polystyrene-polyisoprene (PS-PI) diblock copolymer (10,000-50,000 g/mol) and a matched PS&ndashPI-PS triblock (10,000-100,000-10,000 g/mol) were employed to study the effect of chain architecture on the rheological response of ordered block copolymer melts. Both samples adopt hexagonal microstructures with PS cylinders embedded in a PI matrix; on further heating, an order-order transition (OOT) into a cubic array of spheres takes place prior to the order-disorder transition. Each morphology was verified by SAXS and TEM. Interestingly, at the OOT the low-frequency elastic modulus of the diblock increased abruptly, whereas that of the triblock decreased. In contrast, the modulus of the cubic phase was roughly independent of chain architecture. Chain relaxation parallel and perpendicular to the cylinders was probed by measuring the elastic modulus of a macroscopically aligned sample in directions parallel G′∥ and perpendicular (G′⊥) to the cylinder orientation. For both materials G′∥ 〈 G′R 〈 G′⊥ where G′R is the elastic modulus of a randomly oriented sample. This result is attributed to the ability of the unentangled PS blocks to move along the direction of the cylinder axis, and thus relax the stress in the PI matrix in the parallel alignment. In each of the three cylindrical orientations the triblock had a larger modulus than the diblock, which is attributed to the presence of bridging PI blocks that connect distinct PS domains. About 20° below the OOT G′∥ showed a distinct change in its temperature dependence, which, coupled with SAXS measurements, is indicative of the onset of an undulation in the cylinder diameter that presages the pinching off of cylinders into spheres, as recently predicted by theory. The use of oriented samples also permitted SAXS confirmation of an approximate epitaxial relationship between the cylinder and the sphere unit cells, although a distinct change in the location of the structure factor maximum, q*, is noted at the OOT. © 1997 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 35: 2811-2823, 1997
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...