    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 4-10 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Ion mobility detector ; Plasma chromatography ; Selective detection ; Quantitative analysis ; Halogenated compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An ion mobility detector that has been specifically developed for interfacing with capillary gas chromatography is investigated in the negative ion mode. Like the electron capture detector, to which this instrument is closely related, the ion mobility detector shows an enhanced response to low molecular weight halogenated compounds when a small quantity of oxygen is doped into the make-up gas flow. Under O2 doping conditions, the device can operate in a reactant ion monitoring mode responding universally to compounds capable of capturing thermal electrons and in a tunable selective product ion mode providing increased selectivity over that achieved by the ECD. At an oxygen concentration of 0.5%, minimum detectable amounts as low as 600 femtograms have been realized for carbon tetrachloride. Selectivity of chloro- versus bromo- compounds is demonstrated using a mixture of p-dichlorobenzene and p-dibromobenzene.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 44-48 
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Fused silica capillary columns ; Fourier Transform Ion Mobility Spectrometry ; Ion mobility detector ; Barbiturates ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper demonstrates a novel operating mode of an ion mobility detector (IMD) for obtaining both qualitative and quantitative data after capillary gas chromatographic separation of 5,5′-disubstituted barbiturates. Using a recently developed time dispersive Fourier transform method for ion mobility spectrometry, complete ion mobility spectra could be obtained for each component in the chromatogram. This type of spectra can be used for providing qualitative information on unknown compounds or for selecting the proper detector conditions needed when operating in the continuous mobility monitoring mode.In this study each of the five barbiturates investigated produced a Fourier transformed ion mobility spectrum containing one major product ion. When drift times corresponding to those of the product ions measured in the FT mode were monitored continuously, selective chromatographic detection of the barbiturates was achieved. In one case even isomers could be differentiated based on mobility characteristics.
    Additional Material: 6 Ill.