    Annals of biomedical engineering 11 (1983), S. 67-81 
    ISSN: 1573-9686
    Schlagwort(e): Oxygenation ; Blood oxygenator ; Sulfite ; Mass transfer ; Hemoglobin
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin , Technik allgemein
    Notizen: Abstract Evaluation of blood oxygenators using whole blood is inconvenient and expensive, although it is the ultimate preclinical test. Sodium sulfite solutions have advantages over blood for studying oxygen uptake: They are inexpensive, fewer variables need control, and deoxygenation is unnecessary. Assays and interpretation of results are easy. The kinetics of sulfite oxidation must be fast and the concentration of sulfite must be low to emulate oxygen uptake by blood. The kinetics were studied yielding a first order rate constant in sulfite, zero order in oxygen, of 740/min. Limitations of the technique were evaluated using the experimental rate constant and an adaptation of Lightfoot’s approximation. While the reaction of hemoglobin is reversible and essentially instantaneous, that for sulfite is irreversible and finite. Thus if the approach to saturation is not monotonic or if the mass transfer resistance is significantly lowered, e.g., when blood film thicknesses are thinner than a few hundred microns, deviations may occur. Two TMO oxygenators and several prototypes were tested, with both sulfite and bovine blood. Uptakes of oxygen were comparable and the effect of parameter variations were similar. The use of sulfite for early evaluation of oxygenators is concluded to be very useful.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1573-9686
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin , Technik allgemein
    Notizen: Abstract The interaction of artificial materials with the process of thrombus formation in blood depends on geometric and fluid-mechanical factors as well as the proximity of even slightly injured tissue. A test device that takes account of these factors and is suitable for intravascular implantation is described. The device effects a division of total flow between a tube oriented on the vessel axis, whose diameter is less than that of the vessel, and the annular space between the tube and vessel. Dimensions are chosen to effect thrombogenesis preferentially within the tube. The division of flow is calculated as a function of dimensional ratios and Reynolds number. Other aspects of the fluid dynamical performance of the device are discussed. Results of experimental evaluations in an extracorporeal shunt are reported; they show preferential deposition where expected, small variations among similar experiments, and good ability to distinguish among different materials.