    Journal of clinical monitoring and computing 11 (1994), S. 31-34 
    ISSN: 1573-2614
    Keywords: thermography ; sympathectomy ; peripheral vascular disease
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Notes: Abstract Objective assessment of chemical lumbar sympathectomy (CLS) is lackin.. Its success is usually judged in terms of the patient's clinical improvement. We have thermographically measured the immediate temperature changes of the lower limb following CLS using a thermal imager (SAN-EI Thermotracer 6T61). Seven patients with critical limb ischaemia and one patient with Raynaud's phenomenon underwent unilateral ablation of the lumbar sympathetic chain using 5% phenol. Four patients were diabetic, two of whom had undergone previous sympathectomy on the same side. Within fifteen minutes of injection, all patients showed a rise in skin temperature in parts of the sock distribution of between 0.8°C and 8.5°C. We conclude that the haemodynamic effects of CLS are immediate and can be objectively measured with thermal imaging.