ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 8 (1989), S. 235-245 
    ISSN: 1573-4862
    Keywords: Multi-layer thin film structure ; low-cycle fatigue ; cycle-to-crack ; DC resistance ; dislocation density ; residual stress
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract A multi-layered thin film structure (namely, electrodeposited Cu/sputtered Cr/Kapton substrate/sputtered Cr/electrodeposited Cu), utilized as a flexible component for computers, has been exposed to fatigue. Although a standardized testing method for fatigue ductility is available for a solid monolayer of electrodeposited foil, there is no method available for examining such a multi-layered thin film structure. In this study, four different methods were employed to characterize the low-cycle fatigue damage: (1) DC resistance measurement, (2) residual stress development by x-ray diffraction, (3) dislocation density calculation by using obtained x-ray diffraction line profiles, and (4) microscopic observations. Low-cycle fatigue was conducted at eight levels of applied total strain, i.e., δε T =13.95%, 7.69%, 5.83%, 4.69%, 3.37%, 2.37%, 1.59%, and 1.19%. The number of fatigue cycles, when the crack was first observed on the outer Cu layer, was identical to that observed with the onset of increased resistance. This cycle number is thus designated as the number of cycles-to-fatigue crack initiation,N c . AtN c , the residual stresses also show a noticeable relaxation, and the dislocation density shows a remarkable increase. IfN c is plotted against the applied total strain amplitudes, a Manson-Coffin's relationship is obtained with an exponent of 0.39. It is recommended that monitoring the continuous changes in DC resistance could provide a reliable nondestructive evaluation of low-cycle fatigue life of a multi-layered thin film structure.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 10 (1991), S. 79-87 
    ISSN: 1573-4862
    Keywords: X-ray diffraction ; tensors ; nondestructive evaluation ; residual stress
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract The three-dimensional residual stress condition of copper sputtered on Kapton™ films was studied by two nondestructive x-ray diffraction techniques. Four samples were evaluated—one “control sample,” and three heat-treated samples. Because of concerns about steep stress gradients normal to the specimen surface, an experimental technique described by Dölle(1) was used to obtain the residual strain tensors in the near surface region. The resulting stress tensors were compared to data obtained through a modification of the technique described by Dölle, referred to as the differential method.(2)
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...