ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Pyrene  (1)
  • inference  (1)
  • Springer  (2)
  • 1
    ISSN: 1573-4994
    Keywords: Pyrene ; probe ; polymerization ; differential scanning caiorimetry ; fluorimetry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The polymerization of cyclohexylmethacrylate was monitored, over a wide temperature range, by simultaneous differential scanning calorimetry (DSC) and fluorimetry (FL); the equipment for both being optically coupled. Pyrene was used as a fluorescent probe. There was excellent agreement between the exothermic peak time obtained by DSC and the time at which the maximum gradient was obtained in the fluorescence intensity–time curves, but only for temperatures above 60°C, Activation energies for the gel effect onset were obtained for both, the conversion–time and intensity–time curves being concordant except for data at low temperatures, below 60°C. It was concluded that vitrification occurs at temperatures below 60°C and its presence was demonstrated by fluorimetry, by means of the conversion change associated with the fluorescence intensity jumpΔα(off-on).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-904X
    Keywords: bioequivalence ; absorption rate ; Tmax ; absorption process rate ; measurement theory ; inference
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Purpose. Peak drug concentration (Cmax) measures the extremity of drug exposure and is a secondary indicator of the extent of absorption after area under the concentration time curve (AUC). Cmax serves as the indicator of absorption rate in bioequivalence (BE) studies in the US (1). The use of Cmax, not the time to Cmax(Tmax), as the metric to assess absorption rate causes erratic inferences in BE studies, and incorrect conclusions for some. We can improve BE efficiency (i.e., get the answer right the first time), by properly analyzing the time to Cmax(Tmax) instead of Cmax. Methods. We have previously redirected attention to Tmax as the unconfounded absorption rate variable, instead of Cmax, and have called for equally spaced sampling times during the suspected absorption phase to improve the performance of the rate metric (2). Equal spacing converts Tmax easily into a count variable and we illustrated an appropriate statistical analysis for counts. This paper provides some measurement theory concepts to help judge which is the more appropriate analysis, and also provides parametric confidence limits for Tmax treatment differences. Three separate BE studies are then analyzed by both methods. Results. By focusing on the differences in conclusions, or inferences, this paper identifies three major issues with the current FDA "recommended” analysis of BE studies. First, Cmax, a continuous variable peak-height or extent measure has usurped Tmax's function and performs erratically as a substitute measure for the rate of absorption. Second, Tmax, should be analyzed as a discrete attribute, not as a continuous variable. Third, since several extent measures (AUC, Cmax), not one, are actually being analyzed, an adjustment for multiple testing is mandatory if we are to maintain the size of the test at the desired α level (13), and not inadvertently use a narrower bioequivalence window than is intended. These actions all can have serious unintended consequences on inferences, including making inappropriate ones.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...