ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • FIR laser  (3)
  • betamethasone  (3)
  • Animals
  • Coleus (cell cultures)
  • METEOROLOGY AND CLIMATOLOGY
  • Springer  (8)
Collection
Keywords
Years
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Planta 191 (1993), S. 18-22 
    ISSN: 1432-2048
    Keywords: Coleus (cell cultures) ; Hydroxycinnamic acid ester ; Rosmarinic acid ; Rosmarinic acid synthase (purification)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract Rosmarinic acid synthase from cell cultures of Coleus blumei Benth. was purified to apparent homogeneity by fractionated ammonium sulfate precipitation (60–80% saturation), hydrophobic interaction chromatography, affinity chromatography and gel filtration. This purification procedure resulted in a 225-fold-enriched specific enzyme activity with a yield of 9%. The protein preparation was apparently pure according to sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and two-dimensional gel electrophoresis. The apparent molecular mass determined by gel filtration and SDS-PAGE was 77 kDa, indicating that rosmarinic acid synthase is a monomeric enzyme.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-2048
    Keywords: Coleus (cell cultures) ; Hydroxycinnamic acid ester ; Phenylpropanoid metabolism ; Rosmarinic acid (biosynthetic pathway)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract A biosynthetic pathway for rosmarinic acid is proposed. This pathway is deduced from studies of the enzymes detectable in preparations from suspension cells of Coleus blumei. Phenylalanine is transformed to 4-coumaroyl-CoA by the enzymes of the general phenylpropanoid pathway: phenylalanine ammonia-lyase (EC 4.3.1.5), cinnamic acid 4-hydroxylase (EC 1.14.13.11) and hydroxycinnamic acid:CoA ligase (EC 6.2.1.12). Tyrosine is metabolized to 4-hydroxyphenyllactate by tyrosine aminotransferase (EC 2.6.1.5) and hydroxyphenylpyruvate reductase. The ester can be formed from 4-coumaroyl-CoA and 4-hydroxyphenyllactate by the catalytic activity of rosmarinic acid synthase with concomitant release of CoA. Microsomal hydroxylase activities introduce the hydroxyl groups at positions 3 and 3′ of the aromatic rings of the ester 4-coumaroyl-4′-hydroxyphenyllactate giving rise to rosmarinic acid.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 18 (1980), S. 245-247 
    ISSN: 1432-1041
    Keywords: betamethasone ; pregnancy ; placental transfer ; plasma concentrations ; HPLC assay
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The plasma concentrations of beta-methasone in a maternal peripheral vein (mv) and in the umbilical vein (uv) were measured at delivery in eleven patients after the administration of beta-methasone phosphate equivalent to 8 mg betamethasone. Betamethasone concentrations were measured in plasma using a specific and sensitive HPLC assay. The time interval between the last dose and delivery ranged from 56 min to 800 min and over this time period the mean plasma concentration ratioCuv/Cmv was 0.28±0.04 (SD) and exhibited no time dependence.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 25 (1983), S. 643-650 
    ISSN: 1432-1041
    Keywords: betamethasone ; pharmacokinetics ; cortisol ; high-performance liquid chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of betamethasone and its phosphate ester are described in 8 healthy adults after i. v. bolus injection of 10.6 mg betamethasone phosphate. Both compounds were measured by high-performance liquid chromatography with ultraviolet detection using sample handling methods which prevented hydrolysis of the ester in vitro. Betamethasone phosphate disappeared rapidly from plasma (mean half-life=4.7 min) as betamethasone levels rose. Betamethasone plasma levels reached a peak 10–36 min after administration of the phosphate before declining in a biexponential manner. The terminal slow disposition phase had a mean half-life of 6.5 h. Only about 5% of the dose was recovered from urine as betamethasone, indicating extensive extrarenal clearance of betamethasone. Protein binding and blood/plasma concentration ratio were also determined. In comparison with its stereoisomer, dexamethasone, betamethasone is also cleared mainly by metabolism but has a lower plasma clearance, is less plasma bound, has a higher blood/plasma concentration ratio, and a higher volume of distribution. Endogenous cortisol levels were measured in the subjects who received betamethasone phosphate and in a matched control group of 4 subjects who did not. Betamethasone abolished the normal episodic secretion of cortisol and rapidly reduced its plasma concentration to a basal level. Cortisol plasma levels were not restored at 24 h but had returned to normal by 48 h after dosing.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 25 (1983), S. 803-810 
    ISSN: 1432-1041
    Keywords: betamethasone ; pharmacokinetics in pregnancy ; cortisol ; plasma binding
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of betamethasone and its phosphate ester are described in nine women in late pregnancy who each received a bolus intravenous dose of 10.6 mg betamethasone phosphate. Both compounds were measured by high-performance liquid chromatography with ultra-violet detection using sample handling methods which prevent in vitro hydrolysis of the ester. The plasma clearance of betamethasone phosphate (mean=980 ml/min) and its apparent distribution volume (mean=5.61) were both higher than previously found for nonpregnant subjects, but its half-life (mean=4.6 min) was unchanged. Plasma concentrations of betamethasone reached a peak 5–37 min after dosing with betamethasone phosphate, then declined biexponentially with a mean terminal half-life of 262 min. Plasma clearance in pregnant patients (mean=287 ml/min) was higher than previously reported for nonpregnant subjects. Evidence from urinary excretion and plasma binding measurements and the previously reported transplacental plasma concentration gradient indicated that the increase in clearance was due to increased metabolism possibly by the placental/fetal unit. Plasma binding of betamethasone was higher in maternal than fetal plasma; binding to α1-acid glycoprotein was more important than binding to albumin as a determinant of this difference. In pregnant patients the decline of endogenous cortisol concentrations in maternal venous plasma was less marked and slower than in nonpregnant subjects. The data now available allows comparison of pharmacokinetic properties between betamethasone and its stereoisomer dexamethasone with respect to their use in preventing neonatal respiratory distress syndrome.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 1 (1980), S. 117-126 
    ISSN: 1572-9559
    Keywords: CH2DOH ; CO2 laser ; FIR laser ; laser frequency measurement ; new laser lines ; relative intensity ; relative polarization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We have measured the output powers and relative polarizations of 66 cw FIR laser lines from CH2DOH (including 50 not previously reported), which were optically pumped by a CO2 laser. The frequencies of 43 of these lines were measured relative to stabilized CO2 lasers.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 2 (1981), S. 705-711 
    ISSN: 1572-9559
    Keywords: CD2F2 ; laser frequency measurement ; FIR laser ; new laser lines ; CO2 laser ; wavelengths ; relative polarization ; relative power
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We report for the first time wavelength, relative polarization, and frequency measurements for 47 new cw FIR laser lines in the wavelength region from 120 to 1714 μm, all obtained by optically pumping CD2F2 with a CO2 laser. Relative output powers were also measured. For comparison, the 189.8 μm line pumped by RI(34) is nearly five times as efficient as the 118.8 μm methyl alcohol line.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 4 (1983), S. 401-406 
    ISSN: 1572-9559
    Keywords: CHCl2F ; laser frequency measurement ; FIR laser ; new laser lines ; CO2 laser ; wavelengths ; relative polarization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The wavelengths, frequencies, and relative polarizations of 15 FIR cw lasing lines obtained by optically pumping CHCl2F with a cw CO2 laser have been measured. The lines are in the wavelength range from 340.3 to 905.4 μm and were pumped by P- and R-branch laser lines in the 9 μm band of CO2.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...