ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 04. Solid Earth::04.08. Volcanology::04.08.05. Volcanic rocks  (1)
  • 35.00  (1)
  • Best von Kryptanden, Kryptaten  (1)
  • Best. von Calcium  (1)
  • Analytical Chemistry and Spectroscopy
  • Polymer and Materials Science
  • Springer  (4)
Sammlung
Schlagwörter
Verlag/Herausgeber
Erscheinungszeitraum
  • 1
    Publikationsdatum: 2017-04-04
    Beschreibung: New Sr and Nd isotope data for whole rocks, glasses and minerals are combined to reconstruct the nature and origin of mixing end-members of the 200 km3 trachytic to phonolitic Campanian Ignimbrite (Campi Flegrei, Italy) magmatic system. The least-evolved magmatic end-member shows equilibrium between host glass and the majority of the phenocrysts and is less radiogenic in Sr and Nd than the most-evolved magma. On the contrary, only the Fe-rich pyroxene from the most-evolved erupted magma is in equilibrium with the matrix glass, while all other minerals are in isotopic disequilibrium. These magmas mixed prior to and during the Campanian Ignimbrite eruption and minerals were freely exchanged between the magma batches. Combining the results of the geochemical investigations on magma end-members with geophysical and geological data, we develop the following scenario. In stage 1, a parental, less differentiated magma rose into the middle crust, and evolved through combined crustal assimilation and crystal fractionation. In stage 2, the differentiated magma rose to shallower depth, fed the pre-Campanian Ignimbrite activity and evolved by further open-system processes into the most-evolved and most-radiogenic Campanian Ignimbrite end-member magma. In stage 3, new trachytic magma, isotopically distinct from the pre-Campanian Ignimbrite magmas, rose from ca. 6 km to shallower depth, recharged the most-evolved pre-Campanian Ignimbrite magma chamber, and formed the large and stratified Campanian Ignimbrite magmatic system. During the course of the Campanian Ignimbrite eruption, the two layers were tapped separately and/or simultaneously, and gave rise to the range of chemical and isotopic values displayed by the Campanian Ignimbrite pumices, glasses and minerals.
    Beschreibung: Published
    Beschreibung: 285-300
    Beschreibung: 2.3. TTC - Laboratori di chimica e fisica delle rocce
    Beschreibung: 3.5. Geologia e storia dei vulcani ed evoluzione dei magmi
    Beschreibung: JCR Journal
    Beschreibung: reserved
    Schlagwort(e): Campanian Ignimbrite ; Radiogenic isotopes ; Mixing process ; 04. Solid Earth::04.08. Volcanology::04.08.03. Magmas ; 04. Solid Earth::04.08. Volcanology::04.08.05. Volcanic rocks
    Repository-Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Materialart: article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Applied physics 54 (1992), S. 404-410 
    ISSN: 1432-0630
    Schlagwort(e): 07.65 ; 35.00 ; 42.55 R
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Maschinenbau , Physik
    Notizen: Abstract A pump- and probe-beam technique is used for measuring time-resolved excited-state absorption (ESA) and stimulated-emission (SE) spectra of Er3+ doped YAlO3. The Er3+ 4 I 15/2 → 4 F 7/2 transition of the sample is excited at 488 nm by an excimer laser pumped dye laser. The ESA and SE of broadband xenon flashlamp light is monitored between 300 and 860 nm by an optical multichannel analyzer (OMA). The analysis of the experimental results provides information on the effective cross sections σESA and σSE originating from several levels and on the populations of these levels. To our knowledge this represents the first detailed investigation of time-resolved ESA and SE over a broad spectral range in rare-earth doped materials.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Fresenius' Zeitschrift für analytische Chemie 298 (1979), S. 358-362 
    ISSN: 1618-2650
    Schlagwort(e): Best von Kryptanden, Kryptaten ; Volumetrie ; HCl, Metall-Standardlösung, Standardzugabeverfahren
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Beschreibung / Inhaltsverzeichnis: Summary Using bromocresol green as a visual endpoint indicator solutions of the cryptands [2.2.1] and [2.2.2] can be determined by titration with HCl in the concentration range of 10−1–10−3 M with relative standard deviations of 0.2–0.4 %. If both cryptand and cryptate are present in one solution, then the sum of them can be determined titrimetrically in the same way. It is also possible to determine the contents of [2.2.1] and [2.2.2] by using a calcium or barium standard solution and the unknown cryptand solution as a titrant. By evaluation of the pH-curve thus obtained, the endpoint of the titration can be determined. In the concentration range of 10−1–10−2 M relative standard deviations of about 0.5% are obtained. [2.2.1] cryptand solutions are determined by using the standard addition technique of Gran with a calcium chloride solution. An ion-selective electrode is used as a probe for calcium ions. If this method is applied, the relative standard deviation in the range of 10−2–10−4 M solutions is approximately 3%. With this technique cryptand can be analysed even when cryptate is present in the solution.
    Notizen: Zusammenfassung Bei Verwendung von Bromkresolgrün als visueller Endpunktindicator kann man [2.2.1] und [2.2.2] Kryptandlösungen im Konzentrationsbereich 10−1–10−3 M mit relativen Standardabweichungen von 0,2–0,4% mit HCl titrieren. Wenn in einer Lösung sowohl Kryptand als auch Kryptat vorhanden ist, ist die Summe beider Substanzen auf die gleiche Weise bestimmbar. [2.2.1] und [2.2.2] können auch dadurch bestimmt werden, daß eine Calciumbzw. Barium-Standardlösung mit der Kryptandlösung unbekannter Konzentration titriert wird. Die Auswertung der dabei erhaltenen pH-Kurve ergibt den Titrationsendpunkt, wobei hierdurch im Konzentrationsbereich von 10−1–10−2 M Kryptandlösungen relative Standardabweichungen von etwa 0,5% erreicht werden. [2.2.1] Kryptandlösungen werden außerdem mit der Standard-Additionstechnik nach Gran bestimmt, wobei eine calciumselektive Elektrode als Indicatorelektrode dient. Dabei werden im Konzentrationsbereich von 10−2–10−4 M relative Standardabweichungen von etwa 3 % erhalten. Diese Methode kann auch überschüssigen Kryptand neben Kryptat bestimmen.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Springer
    Fresenius' Zeitschrift für analytische Chemie 287 (1977), S. 121-127 
    ISSN: 1618-2650
    Schlagwort(e): Best. von Calcium ; in Mineralien ; Isotopen-verdünnung/Massenspektrometrie ; Ionenaustauscher, Thermionen-MS
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Beschreibung / Inhaltsverzeichnis: Zusammenfassung Ein Verfahren zur massenspektrometrischen Isotopenverdünnungsanalyse geringer Calciumkonzentrationen in Mineralien wurde entwickelt. Die einzelnen analytischen Teilschritte (Aufschlußverfahren mit Isotopenverdünnung, Calciumseparation und massenspektrometrische Messung) des Gesamtverfahrens werden beschrieben. Für einen 42Ca-Indicator wird die optimale Indicatorzugabe sowie Auswirkungen der massenspektrometrischen Messungen auf den Fehler des Analysenverfahrens diskutiert. Bei der chromatographischen Calciumabtrennung an einem stark sauren Ionenaustauscher wird eine vollständige Separation von Kalium erreicht. Der Calciumgehalt im Bereich von 0,15–0,004 Gew.-% zweier Kalifeldspäte und eines Lepidolithen wird mit externen relativen Standardabweichungen von 0,9–5,1% bestimmt.
    Notizen: Summary A mass spectrometric isotope dilution analysis for the determination of small calcium contents is developed. The different steps (decomposition of the mineral including isotope dilution technique, calcium separation and mass spectrometric measurement) of the analytical procedure are described. For a 42Ca spike the optimum spike addition is calculated. The dependence of the analysis error on the mass spectrometric measurements is discussed. Using a chromatographic method with a strong acidic ion exchanger calcium can be completely separated from potassium. The calcium content in the range of 0.15–0.004% of two feldspars and of one lepidolite is determined with external relative standard deviations of 0.9–5.1%.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...