ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 04. Solid Earth::04.06. Seismology::04.06.10. Instruments and techniques  (1)
  • 04. Solid Earth::04.06. Seismology::04.06.06. Surveys, measurements, and monitoring
  • Lunar and Planetary Science and Exploration
  • Mueller
  • earth mantle
  • Seismological Society of America  (1)
Sammlung
Schlagwörter
Verlag/Herausgeber
Erscheinungszeitraum
  • 1
    Publikationsdatum: 2017-04-04
    Beschreibung: In order to evaluate detection and localization capabilities of a future array in the Upper Tiber Valley (Northern Apennines – Italy), an irregularly configured test array was installed near Città di Castello (CDC) for a period of two weeks, consisting of nine sites with inter-sensor distances between 150 and 2200 m. This test-array installation is particular in its use of three component sensors at all array sites, which allows the application of all array specific analyses techniques for the full seismic wavefield, i.e., also for horizontal-component data. In this study we investigate the inter-sensor coherence of the seismic noise field for the test-array area. In addition to the “classic” noise analysis, where noise cross-correlation values are calculated at single vertical instruments without relative time shifts between the traces, we extend the study by a “dynamic” approach, which accounts for possible slowness characteristics of the noise field. Furthermore, we investigate how the noise characteristics are dependent on the chosen component of the seismic sensors, by analyzing the noise coherence not only between vertical components but also on the radial and the transverse components. The coherence found for noise observed by the different sensors of the test array shows strong azimuthal variations on all components, which are most pronounced for noise within the frequency passband of 1.5 - 4.0 Hz and an apparent velocity of 1.5 km/s (Rg waves). The calculated correlation lengths of noise observed for the CDC array are about half of the values found for the NORES array in Southern Norway. Therefore, a future permanent array installation should be planned for minimum inter-sensor distances between 150 and 200 m.
    Beschreibung: Published
    Beschreibung: 1876-1886
    Beschreibung: 1.1. TTC - Monitoraggio sismico del territorio nazionale
    Beschreibung: JCR Journal
    Beschreibung: open
    Schlagwort(e): seismic array ; noise field ; 04. Solid Earth::04.06. Seismology::04.06.10. Instruments and techniques
    Repository-Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Materialart: article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...