ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Nature Publishing Group  (3)
Collection
Years
  • 1
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 184 (1959), S. 978-979 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] The method is based on the circular gas chromato-graph already described1. The apparatus consisted of two 5-ft. copper columns of -in. outside diameter connected through a circulating pump at one end and a thermal conductivity detector and injection system at the other. Each column contained 12'25 ...
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 192 (1961), S. 752-753 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] Fig. 1. Multi-column unit As an example of apparatus performance, Table 1 gives results on the fractionation of 34 gm. of 'Vistanex LM-MS\ a commercial polyisobutylene. The columns were packed with glass beads, average diameter 0*1 mm. The non-solvent employed was acetone, the solvent ...
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 183 (1959), S. 391-392 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] The stationary liquid phase normally used in gas chromatography has a low volatility relative to the compounds being separated. With the circular apparatus, the liquid need not have a low volatility. Fig. 2 shows the record for separation at room temperature of acetone, boiling point 56 -2 C, and ...
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...