ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Books  (37)
  • Hanover, NH : U.S. Army Cold Regions Research and Engineering Laboratory  (21)
  • Open Book Publishers  (16)
Collection
  • Books  (37)
Language
Branch Library
Reading Room Location
  • 1
    Call number: ZSP-201-78/28
    In: CRREL Report, 78-28
    Type of Medium: Series available for loan
    Pages: x, 112 Seiten , Illustrationen
    Series Statement: CRREL Report 78-28
    Language: English
    Note: CONTENTS Abstract Preface Conversion factors Introduction Descriptions of road test sections Test equipment and procedures Field repetitive plate bearing tests Data analysis General Layered-elastic analysis of the pavement systems Statistical analysis Flexural analysis Summary and conclusions Literature cited Appendix A: Resilient surface deflections for the test points
    Location: AWI Archive
    Branch Library: AWI Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Series available for loan
    Series available for loan
    Hanover, NH : U.S. Army Cold Regions Research and Engineering Laboratory
    Associated volumes
    Call number: ZSP-201-77/17
    In: CRREL Report, 77-17
    Description / Table of Contents: A literature search was made for information on the accretion of ice on ocean structures and on methods for control. The bulk of the reports were in Russian, with some additional Japanese, British, American, Canadian, and Icelandic sources. Analysis of icing reports indicated that sea spray is the most important cause of ship icing, with lesser amounts due to freezing rain, snow, and fog. Icing is a potential danger whenever air temperatures are below the freezing point of water and the sea temperature is 6 C or lower. Theoretical work on the ice accretion process is discussed, and a method is suggested, based on Russian experiments, for calculating the sea spray accumulation rate for cylindrical and flat surfaces as a function of water source temperature, air temperature, and wind speed. Other factors that influence icing severity are ship size and configuration, angle between ship course and water heading, and ship speed. Icing in the north temperate latitudes generally occurs in the rear of barometric depressions. Maps showing limits of various degrees of icing severity are included. Atmospheric icing measurements on tall land-based structures are presented, and potential maximum accumulations estimated. Control measures are discussed, though no completely effective method is available. Mechanical (impaction) methods are the most common, but experiments have been conducted on heated, icephobic, and deformable surfaces, and with freezing point depressants. No device for the unequivocal measurement of ice accumulation is available, though some experimental methods are suitable for controlled testing; it is recommended that a device be developed.
    Type of Medium: Series available for loan
    Pages: v, 42 Seiten , Illustrationen
    Series Statement: CRREL Report 77-17
    Language: English
    Note: CONTENTS Abstract Preface Conversion factors: U.S. customary to metric units of measurements Introduction The freezing proeess Icing observations Geographical distribution of icing and contributing meteorological conditions Extreme icing conditions Extremes of icc accumulation Prediction of icing occurrences Prediction of icing intensity and rate Control methods Measurement of icing rate Conclusions and recommendations Literature cited Appendix A. Maps of icing occurrence and rate Appendix B. Data for computing ship icing rates Appendix C. Estimation of ice accumulation
    Location: AWI Archive
    Branch Library: AWI Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Call number: ZSP-201-78/23
    In: CRREL Report, 78-23
    Type of Medium: Series available for loan
    Pages: vi, 53 Seiten , Illustrationen
    Series Statement: CRREL Report 78-23
    Language: English
    Note: CONTENTS Abstract Preface Nomenclature Conversion factors: Metric (SI) to U.S. customary units of measurement Introduction Selection of experimental approach Previous investigations of effect of freeze-thaw on soil deform ability Selection of laboratory test method Selection of method of field validation tests Field repeated-load plate-bearing tests Test pavements, soils and materials Test procedures and results Resilient modulus of subgrade calculated from field tests Mathematical model Characterization of asphalt concrete Characterization of frozen silt Calculated resilient modulus of silt within the zone of freezing Laboratory repeated-load triaxial tests Specimens, equipment and testing procedures Apparatus Procedures Resilient properties calculated from laboratory tests Calculation methods Asphalt concrete - test results Asphalt concrete - statistical analysis and discussion Silt - test results Silt - statistical analysis Discussion and conclusions Literature cited Appendix A. Repeated-load plate-bearing test results Appendix B. Laboratory repeated-load triaxial test results Appendix C. Regression equation coefficients for resilient modulus and Poisson’s ratio from repeated-load triaxial test data on asphalt concrete and silt Appendix D. Detailed procedures for repeated-load triaxial testing
    Location: AWI Archive
    Branch Library: AWI Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Series available for loan
    Series available for loan
    Hanover, NH : U.S. Army Cold Regions Research and Engineering Laboratory
    Associated volumes
    Call number: ZSP-201-77/28
    In: CRREL Report, 77-28
    Description / Table of Contents: Tests were conducted to assess the extent of surface degradation resulting from the application of non-chloride deicing chemicals on three types of airfield pavements. The chemicals tested were proprietary mixtures of urea, formamide, and ethylene glycol; sodium chloride, distilled water, and dry specimens were used as controls and for comparison. Pavements included new and old specimens of open-graded asphaltic concrete and old specimens of dense-graded asphaltic concrete. Portland cement concrete specimens used were new and old, with and without air-entrainment. New and old tar rubber concrete specimens were also tested. Samples were subjected to up to 60 freeze-thaw cycles with deicing chemicals flooding their upper surface. Each specimen was rated on a scale of 0-5 after every five freeze-thaw cycles. All PCC specimens showed some surface degradation, whereas the dense- and open-graded asphaltic concretes were largely unaffected.
    Type of Medium: Series available for loan
    Pages: v, 16 Seiten , Illustrationen
    Series Statement: CRREL Report 77-28
    Language: English
    Note: CONTENTS Abstract Preface Conversion factors: U.S. customary to metric (SI) Units of measurement Introduction Test procedure Pavement types Deicing chemicals Description of tests Discussion Literature cited Appendix A: Test results Appendix B: Portland cement concrete materials data
    Location: AWI Archive
    Branch Library: AWI Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Series available for loan
    Series available for loan
    Hanover, NH : U.S. Army Cold Regions Research and Engineering Laboratory
    Associated volumes
    Call number: ZSP-201-77/11
    In: CRREL Report, 77-11
    Description / Table of Contents: Two performance indicators, effectiveness and thermal efficiency, are defined and used to evaluate the year-round performance of three protected membrane roofs in Alaska and New Hampshire. Effectiveness is a measure of the deviations of ceiling temperatures from a yearly average, with large diviations indicating erratic performance in the roofing-insulation system and small departures indicating a thermally stable system. Thermal efficiency, the ratio of calculated heat loss to measured heat loss, is affected by climatic conditions such as rain, snow, solar radiation and wind. Thermal efficiency values of 100% or greater are possible since the calculated heat loss is based only on the inside and outside air temperature differences and the thermal properties of the roof components. Results of the year-round evaluation indicate that the three protected membrane roofs generally have high values of both effectiveness and thermal efficiency.
    Type of Medium: Series available for loan
    Pages: v, 40 Seiten , Illustrationen
    Series Statement: CRREL Report 77-11
    Language: English
    Note: CONTENTS Abstract Preface Conversion factors: U.S.customary to metric (SI) units of measurement Introduction Location of test sites Fairbanks Anchorage Hanover, N.H. Test program Instrumentation Effectiveness Therma lefficiency Heat balance within the roof Comparisons with conventional systems Conclusions Effectiveness of the test roof Thermal efficiency Heat balance within the roof Applicability Recommendations Literature cited Appendix A. Temperature and heat flow measurements, Anchorage and Fairbanks, Alaska, and Hanover, New Hampshire Appendix B. Thermal efficiencies of the test roof, Anchorage and Fairbanks, Alaska, and Hanover, New Hampshire Appendix C. January 1973 and August 1972 comparisons of protected membrane and conventional built-up membrane systems at Hanover, New Hampshire
    Location: AWI Archive
    Branch Library: AWI Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Series available for loan
    Series available for loan
    Hanover, NH : U.S. Army Cold Regions Research and Engineering Laboratory
    Associated volumes
    Call number: ZSP-201-76/2
    In: CRREL Report, 76-2
    Description / Table of Contents: The repair and maintenance costs of low slope roofs are high and their life expectancy is less than desired. The increasing use of insulation is accompanied by a greater incidence of problems. The experience in cold regions amplifies these experiences. Protected membrane roofs have the prerequisites for better performance and the experience to date is encouraging. The results of performance measurements of three roofs built by the Corps of Engineers verify that the membrane remains at nearly constant temperature, independent of the weather, and that the insulation retains its integrity despite periodic wetting. Moisture absorption is slow and appears to stabilize in time due to the self-drying nature of the roof. Heat losses are increased due to rain, and extra insulation should be added to compensate for these losses. The resistance of protected membrane roofs to fire, traffic, impact, and other adverse forces is superior. So far, the initial cost of protected membrane roofs is at a premium, primarily due to the cost of concrete pavers. The initial cost premium can be justified, however, by the reduced repair and maintenance costs as indicated to date, and by the longer life expectancy of the protected membrane. The high probability of superior performance and cost effectiveness is a compelling reason to incorporate protected membrane roofs increasingly in Government construction.
    Type of Medium: Series available for loan
    Pages: v, 27 Seiten , Illustrationen
    Series Statement: CRREL Report 76-2
    Language: English
    Note: CONTENTS Page Abstract Preface Introduction Low slope roof problems and repair costs Protected membrane roofs and materials Installations of protected membrane roofs Performance evaluation Test program Effectiveness Thermal efficiency Heat balance Internal cooling due to rain Moisture absorption and thermal conductivity of insulations Durability and life expectancy Fire resistance Patent considerations Costs of roofs Design considerations Proposed specifications Conclusions and recommendations Literature cited
    Location: AWI Archive
    Branch Library: AWI Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Call number: ZSP-201-86/13
    In: CRREL Report, 86-13
    Description / Table of Contents: Stress-deformation data for six granular soils ranging from sandy silt to dense-graded crushedstone were obtained from in-situ tests and laboratory tests. Surface deflections were measured in the in-situ tests, with repeated-load plate-bearing and falling-weight deflectometer equipment, when the six granular soils were frozen, thawed, and at various stages of recovery from thaw weakening. The measured deflections were used to judge the validity of procedures developed for laboratory triaxial tests to determine nonlinear resilient moduli of specimens in the frozen, thawed, and recovering states. The validity of the nonlinear resilient moduli, expressed as functions of externally applied stress and moisture tension, was confirmed by using the expressions tocalculate surface deflections that were found to compare well with deflections measured in the in-situ tests. The tests on specimens at various stages of recovery are especially significant because they show a strong dependence of the resilient modulus on moisture tension, leading to the conclusion that predictions or in-situ measurements of moisture tension can be used to evaluate expected seasonal variation in the resilient modulus of granular soils.
    Type of Medium: Series available for loan
    Pages: iv, 148 Seiten , Illustrationen
    Series Statement: CRREL Report 86-13
    Language: English
    Note: CONTENTS Abstract Preface Introduction Test sections Installing instruments and sampling Laboratory tests Asphalt concrete Base, subbase and subgrade soils Data analysis for base, subbase and subgrade soils Field tests Analysis of plate loading tests Analytical approach Results Discussion Conclusions Literature cited Appendix A: Field data Appendix B: Ground temperatures, moisture tension, water table and freezing iso-therms prevailing during plate loading tests Appendix C: Measured surface deflections compared with deflections calculated by NELAPAV Appendix D: Resilient moduli and supporting data calculated by NELAPA V at radius 0.0, taxiways A and B.
    Location: AWI Archive
    Branch Library: AWI Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Series available for loan
    Series available for loan
    Hanover, NH : U.S. Army Cold Regions Research and Engineering Laboratory
    Associated volumes
    Call number: ZSP-201-87/15
    In: CRREL Report, 87-15
    Description / Table of Contents: Constant strain-rate tension tests were conducted on remolded saturated frozen Fairbanks silt at various temperatures, strain rates, and densities. It was found that the critical strain rate of the ductile-brittle transition is not temperature-dependent at temperatures down to -5°C, but varies with density. The peak tensile strength decreases considerable with decreasing strain rate for ductile failure, but it decreases slightly with increasing strain rate for brittle fracture. The failure strain remains almost constant at temperatures lower than about -2°C, but it varies with density and strain rate at -5°C. The initial tangent modulus is independent of strain rate and increases with decreasing temperature and density.
    Type of Medium: Series available for loan
    Pages: v, 29 Seiten , Illustrationen
    Series Statement: CRREL Report 87-15
    Language: English
    Note: CONTENTS Abstract Preface Nomenclature Introduction Testing Material Specimen preparation Testing procedure and apparatus Results Discussion Peak tensile strength, σm Failure tensile strain, ϵf Initial tangent modulus and 50% peak strength modulus Discussion of test techniques Conclusions Literature cited Appendix A: Physical properties of Fairbanks silt specimens Appendix B: Unfrozen water content data of Fairbanks silt with three typical water contents
    Location: AWI Archive
    Branch Library: AWI Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Series available for loan
    Series available for loan
    Hanover, NH : U.S. Army Cold Regions Research and Engineering Laboratory
    Associated volumes
    Call number: ZSP-201-81/18
    In: CRREL Report, 81-18
    Description / Table of Contents: During the growing seasons of 1977, 1978, and 1979, revegetation techniques were studied on the Chena River Lakes Project, a flood control dam and levee near Fairbanks, Alaska, to find an optimal treatment for establishing permanent vegetation cover on the gravel structures. The treatments tested on plots at the dam andor levee involved three main variables 1 vegetation grass and clover seed andor willow cuttings, 2 mulch, mulch blanket, andor sludge, and 3 substrate gravel or fine-grained soil over the gravel base. The mulches were hay, wood-cellulose-fiber, peat moss, and Conwed Hydro Mulch 2000, which is a wood-cellulose-fiber mulch with a polysaccharide tackifier. A constant rate of fertilizer was applied to all plots except the control. A section of each plot was refertilized again in their third growing season to compare annual and biannual fertilization. The high fertilization rate produced above-average growth. Fescue, brome, and foxtail were the most productive species on the dam, while alsike cover was the most productive on the wetter levee site. When grass seed and willow cuttings were planted at the same time, willow survival and growth were reduced. Fertilization is required for at least two years to produce an acceptable permanent vegetation cover, although fine- grained soil or sludge reduces the amount of fertilizer needed in the second year. Third-year fertilization may not be necessary since the benefits of the second fertilization continue for at least two years. A sludge treatment refertilized during its second growing season produces the highest biomass recorded in this study.
    Type of Medium: Series available for loan
    Pages: ix, 59 Seiten , Illustrationen
    Series Statement: CRREL Report 81-18
    Language: English
    Note: CONTENTS Abstract Preface Abbreviations Conversion factors Summary Introduction Background Site characterization Climate Purpose Materials and methods General Moose Creek Dam site Tanana Levee site Sampling and measurement Abiotic controls on vegetation Meteorological data Soil moisture as a limiting factor Soil chemical analysis Vegetation growth and survival Moose Creek Dam site Tanana Levee site Biomass by species Roof penetration Seedling density of invading woody species Weeds Supplemental observations Sediment loss Sludge and runoff-water composition Cost analysis Conclusions Literature cited Appendix A: 1977 grass growth on 1977 dam treatments Appendix B: 1978 grass growth on 1977 dam treatments Appendix C: 1979 grass growth on 1977 dam treatments Appendix D: Grass growth on 1978 dam treatments Appendix E: 1977, 1978, and 1979 survival of willow treatments Appendix F: Grass growth on Tanana levee treatments Appendix C: Chemical analysis of sludge and runoff water
    Location: AWI Archive
    Branch Library: AWI Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Series available for loan
    Series available for loan
    Hanover, NH : U.S. Army Cold Regions Research and Engineering Laboratory
    Associated volumes
    Call number: ZSP-201-86/5
    In: CRREL Report, 86-5
    Description / Table of Contents: This work presents the results of a study to examine the effects of grain size of internal microfractures in polycrystalline ice. Laboratory-prepared specimens were tested under uniaxial, constant-load creep conditions at -5 C. Grain size ranged from 1.5 to 6.0 mm. This range of grain size, under an initial creep stress of 2.0 MPa, led to a significant change in the character of deformation. The finest-grained material displayed no internal cracking and typically experienced strains of 10 to the minus 2nd power at the minimum creep rate epsilon. The coarse-grained material experienced severe cracking and a drop in the strain at epsilon min to approximately 4x10 to the minus 3rd power. Extensive post-test optical analysis allowed estimation of the size distribution and number of microcracks in the tested material. These data led to the development of a relationship between the average crack size and the average grain size. Additionally, the crack size distribution, when normalized to the grain diameter, was very similar for all specimens tested. The results indicate that the average crack size is approximately one-half the average grain diameter over the stated grain size range. A dislocation pileup model is found to adequately predict the onset of internal cracking. The work employed acoustic emission techniques to monitor the fracturing rate occurred. Other topics covered in this report include creep behavior, crack healing, the effect of stress level on fracture size and the orientation of cracked grains. Theoretical aspects of the grain size effect on material behavior are also given.
    Type of Medium: Series available for loan
    Pages: v, 79 Seiten , Illustrationen
    Series Statement: CRREL Report 86-5
    Language: English
    Note: CONTENTS Abstract Preface Background Present research in perspective Explanations of the grain-size dependency Grain size effects on the ductile to brittle transition Nucleation mechanisms and modeling Characteristic size of nucleated crack Cracking in ice Detection of internal fracturing by acoustic emission techniques Test methods Specimen preparation Creep testing apparatus Crack length and crack density measurements Crack healing measurements Thin section photographs Grain size determination Acquisition of acoustic emission data Presentation of results Specimen characteristics Microcrack measurements Creep behavior Crack healing Slip plane length distribution Acoustic emission observations Grain orientation Analysis and discussion Thick section observations The grain size vs crack size relationship Crack nucleation condition Crack density and specimen strain Creep behavior Normalized crack length Location of cracks Acoustic emission activity Summary and conclusions Suggestions for future work Literature cited Appendix A: Crack length histograms Appendix B: Crystal orientations
    Location: AWI Archive
    Branch Library: AWI Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...