ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Gas chromatography  (8)
  • Capillary gas chromatography  (3)
  • Wiley-Blackwell  (11)
  • American Society of Hematology
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 329-332 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary columns ; Deactivation ; Polymethylhydrosiloxanes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 741-747 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary columns ; Deactivation ; Cyanopropylhydrosiloxanes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is described for surface deactivation and modification of fused silica capillary columns with a cyanopropyl-containing reagent. The deactivation procedure involved a dehydrocondensation reaction between a bis(cyanopropyl)methylhydropolysiloxane reagent and surface silanol groups at an optimum temperature of only 250°C. Actual critical surface tension measurements were made using the capillary rise method. Excellent deactivation for acidic and basic compounds at the low ng level, and wettability for nonpolar and polar polysiloxane stationary phases were obtained. A procedure was developed to remove acidic impurities that are present in polar stationary phases.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 413-416 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Stationary phase stability ; Stationary phase viscosity ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: With recent advances in column technology it is now possible to prepare highly efficient, very inert, and thermally stable capillary columns coated with nonpolar polysiloxane stationary phases. Unfortunately, the same degree of success has not been achieved for some of the more polar polysiloxane phases. A parameter that has been studied little in the past in relation to stationary phase film stability is the viscosity of the stationary phase. In this paper the efficiency and stability of coated columns are correlated to the viscosity of the phase. Due to their structure, the viscosity of the phenyl-containing polysiloxanes change rapidly with temperature and hence, thin-film coatings are not stable at elevated temperatures. By using high viscosity phenyl-containing methylphenylpolysiloxanes which were recently synthesized, efficient and stable columns have been prepared.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 319-321 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Supercritical fluid chromatography ; Small diameter capillary columns ; Static coating at elevated temperature ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 75-81 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Element selective detection ; Radio frequency plasma ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A radio frequency plasma detector for element specific detection in gas chromatography is described. The detector is comprised of a radio frequency (300 kHz) discharge between electrodes in helium, and utilizes a low-resolution emission spectrometer to monitor selected spectral emission lines produced when the helium discharge decomposes and excites the atomic constituents in the chromatographic column effluent. The spectrometer is tuned to an atomic emission line in the near-infrared portion of the spectrum, and the emission intensity from the discharge region of a selected line is used to monitor the concentration of the element producing that line. Acceptable detector sensitivity was achieved by the use of a high-throughput optical system. Selectivity was achieved by a combination of correct line selection, plasma and carrier gas purification, and plasma gas doping.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 193-207 
    ISSN: 0935-6304
    Keywords: Multidimensional chromatography ; Liquid chromatography ; Gas chromatography ; Gupercritical fluid chromatography ; Fuels ; Foodstuffs ; Environmental ; Biological ; Pharmaceutical ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Although coupled liquid chromatographygas chromatography (LC-GC) was first demonstrated ten years ago, only in the last few years has there been a sudden surge of interest in the technique. Approximately 70% of the total number of LC-GC applications have been published in the last two years (1987-88) alone. This review categorizes LC-GC publications into four main application areas: fossil fuels, foods, environmental samples, biologiical/pharmaceutical samples, and miscellaneous samples. Multidimensional separations carried out using other coupled-column chromatographic techniques (such as supercritical fluid chromatography (SFC) with GC, and on-line trace enrichment-GC) have also been included in this review.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 89-92 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Stationary phase ; Polysiloxane ; Autocrosslinkable ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Methyl-2-phenylethylpolysiloxane polymers have been synthesized for comparison with methylphenylpolysiloxane stationary phases for gas chromatography. The 50% 2-phenylethyl polysiloxane was found to be autocrosslinkable at 260°C without addition of free redical initiator. Although the selectivity of this phase appears to be similar to the 50% phenyl polysiloxane, its thermal stability is not as high.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Environmental tobacco smoke ; Sampling ; Tenax ; Nicotine, 3-Ethenylpyridine, Particulate nicotine ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A combined sampling and analysis technique for the determination of gas phase nicotine and 3-ethenylpyridine, and of particulate phase nicotine in environmental tobacco smoke with capillary gas chromatography is reported. The major advantage of the technique is that all of the collected particulate phase material is analyzed by thermal desorption of the collected material rather than by analysis of only a fraction of the sample extracted from the collection medium. A Teflon filter microtube is used to collect particulate phase nicotine. This microtube is follwed by a small Tenax sorbent bed to collect gas phase nicotine and 3-ethenylpyridine. After sampling, the Teflon filter is transferred to a clean glass tube and the tube becomes an insert for a modified packed column injector port where the material collected on the filter is heat desorbed to a cold capillary tubing trap. Gas phase nicotine and 3-ethenylpyridine are also transferred from the Tenax to the GC column by thermal desorption from the Tenax sorbent bed. Gas phase nicotine and 3-ethenylpyridine, and particulate phase nicotine are each determined by GC analysis of the desorbed material. Nicotine and 3-ethenylpyridine are quantitated by the use of external standards. This technique is straightforward and can be used for semi-real time determination of both gas and particulate phase compounds in environmental tobacco smoke. The results obtained by this technique compare well with those obtained by sampling with annular diffusion denuders.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 10 (1987), S. 128-136 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Coating of capillaries, static and dynamic ; Rayleigh instability ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The film of stationary phase on the wall of a capillary column and that of the phase solution during both static and dynamic coating is subject to Rayleigh instability, which is quite independent of so-called wettability. A theory is developed which shows that the logarithmic growth rate of Rayleigh instabilities is proportional to the surface tension and to the third power of the film thickness, and inversely to the viscosity and to the fourth power of the capillary diameter. Determination of the variation of the viscosities of stationary phase solutions with concentration in coating solvents, and the variation of the viscosities of neat stationary phases with temperature, both revealed that heating and/or diluting changed the viscosities of phases with π-electron-containing, groups much more than for polydimethylsiloxanes. Rayleigh instability is therefore more important during coating of phenyl-containing phases such as OV-17, and later during column operation. The efficiencies of capillary columns of different diameters coated with a number of phases under different conditions of temperature and coating rate, and then operated at different temperatures were in good agreement with the predictions of the theory.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 13-18 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Biphenyl polysiloxane ; Stationary phase ; Polarizable phase ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A crosslinkable biphenylmethylpolysiloxane stationary phase was synthesized for capillary column gas chromatography and compared with methyl, phenyl, and cyanopropyl polysiloxane stationary phases for the separation of isomeric polycyclic aromatic compounds. While the new phase gave similar separations of nonpolar isomers when compared to the nonpolar phases, separations of polar isomers were greatly improved because of the induced polarity of the biphenyl group of the stationary phase by the solute molecules. This polarizable stationary phase offers a unique selectivity which is not available in other stationary phases.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...