  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 355-357 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We present the design and performance of a magnetic circuit suitable for magnetizing solid samples in the measurements of soft x-ray emission dichroism excited by synchrotron radiation. The system allows a variety of samples to be magnetized and satisfies the rather stringent geometrical constraints due to the need for minimizing the effect of photon self-absorption by the sample. The magnetic circuit is ultrahigh vacuum compatible, can reach about 2800 G, and allows fine adjustment of sample position. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 1610-1615 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: PoLIFEMo (Polarized Light Improved Flux Efficiency Monochromator) is the name of a spherical grating monochromator designed with the purpose of maximizing the photon intensity on a sample. The device is mainly conceived to improve performances of an x-ray emission spectrometer, whose limiting factor is often the counting rate. By keeping the exit slit fixed, it is possible to get a small spot size (∼35 μm vertically) on a sample placed just near the exit slit, without the need of postgrating refocusing optics. No entrance slit is used because of the low beam divergence, allowing the use of a virtual source in a converging beam geometry. The tuning of the output energy is done by translating and pitching the spherical grating. The resolving power is higher than 1000 over the whole energy range (500–1500 eV). A detailed analysis of the optical performances is given, mostly in comparison with the Dragon-type monochromator. The actual realization of the device is described, together with the specific motivations and the experimental performances. PoLIFEMo has been installed on beam line ID12B at the European Synchrotron Radiation Facility since July 1996. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 62 (1991), S. 639-642 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A simple and cost effective inverse photoemission spectrograph based on a spherical grating with very large optical acceptance ( f/2.8) is described. The system works in the 10–25 eV photon energy range. The dispersed photons are detected by a detector assembly based on a microchannelplate and consisting of twelve independent channels. Measurements are taken in the isochromat mode by sweeping the impinging electron energy, and the acquisition of the twelve channels is done in parallel. As an example of the apparatus performances data on polycrystalline Pt are presented.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...