ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Drugs  (1)
  • Glycoprotein  (1)
  • Wiley-Blackwell  (2)
  • American Chemical Society
  • Cell Press
  • Wiley
  • 1
    ISSN: 0173-0835
    Keywords: Antibiotics ; Chiral separations ; Enantiomers ; Drugs ; Herbicides ; Capillary electrophoresis ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: A new glycopeptide antibiotic, MDL 63,246 (Hepta-tyr), of the teicoplanin family, has been evaluated in capillary electrophoresis for the resolution of chiral compounds of pharmaceutical and environmental interest. Electrophoretic separations were carried out in a polyacrylamide-coated capillary using the partial filling-counter current mode with aqueous-organic buffers in the pH range 4-6. Experimental parameters affecting resolution, such as antibiotic concentration, buffer pH, organic modifier type and capillary temperature, were studied. The Hepta-tyr antibiotic exhibited a high enantiorecognition capability towards the studied compounds at very low concentrations (1-2 mg/mL). The optimum experimental conditions were achieved by using a buffer at pH 5 containing acetonitrile at 25°C.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0173-0835
    Keywords: Glycoprotein ; Glycopeptide ; Peptide ; Capillary electrophoresis ; Mass spectrometry ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: An evaluation of capillary zone electrophoresis-mass spectrometry (CZE-MS) as an analytical methodology for the separation and characterization of complex glycopeptides and nonglycopeptide structures has been performed. The evaluation employed endoproteinase V8 digested recombinant human erythropoietin (rHuEPO) that was further fractionated by reverse phase chromatography. The peptides were subjected to sequence analysis and evaluated by capillary electrophoresis, with or without mass detection, for peptide purity. The peptide mass determined from the sequence was then compared to the mass obtained from CZE-MS. Glycosylation sites and carbohydrate branch patterns were easily determined, site specific microheterogeneity (either O-acetylation of N-acetylneur-aminic acids or lactosamine extensions of the carbohydrate chain length) was assessed directly, glycosylation site occupancy was evaluated qualitatively, and nonglycopeptides were resolved and analyzed on-line with ease. Incomplete peptide digestion products were detected and identified by CZE-MS. Protein sequence coverage by CZE-MS was 98.2 percent complete from a single map. Offline evaluation of peptide purity by CZE greatly aided the interpretation of multiple sequence analysis and, in validating that, the CZE-MS was detecting all peptides present. All off-line CZE and on-line CZE-MS experiments employed a capillary that was dynamically coated with Polybrene in the presence of polyethylene glycol; separations were conducted in 0.67 M formic acid.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...