ISSN:
1618-2650
Source:
Springer Online Journal Archives 1860-2000
Topics:
Chemistry and Pharmacology
Description / Table of Contents:
Summary X-Ray-analysis has been proved to be a reliable method for fast control of the production of Si- and Ca-alloys. The elements Si, Ca, Al, Fe, Mn and Ti can be determined in the range from 0.1% to more than 50% (Si to more than 90%). Also most of the rare earths (0.1–15%) in Si-alloys are separately analysed. Sample preparation was described and investigation was made to determine the influence of particle size on the counting rate. Several calibration curves and their derivation by change of constituents are shown.
Notes:
Zusammenfassung Bei der Untersuchung von Si- und Ca-Legierungen hat sich die Röntgenfluorescenzanalyse als Methode zur schnellen Produktionsüberwachung gut bewährt. Die Elemente Si, Ca, Al, Fe, Mn, Ti werden in Gehalten von 0,1 bis über 50% (Si bis über 90%) bestimmt. Bei Si-Legierungen mit Zusätzen von Seltenen Erden (0,1–15%) werden einzelne Erdmetalle getrennt analysiert. Probenaufbereitung sowie Einfluß der Korngröße bei der Messung der Impulsraten werden beschrieben. Einige Eichkurven und deren Verschiebung durch Konzentrationsänderung der Legierungspartner werden gezeigt.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1007/BF00468911