ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1965-1969  (3)
Collection
Publisher
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Rheologica acta 8 (1969), S. 229-234 
    ISSN: 1435-1528
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Zusammenfassung Die Gelenksteifheit wird durch exakte physikalische Größen definiert. Es werden Methoden beschrieben, mit denen die Gelenksteifheit objektiv, qualitativ und quantitativ gemessen werden kann. Es wird eine Apparatur vorgestellt, die Messungen am Knie- und dem zweiten Metacarpophalangeal-Gelenk gestattet. Den Hauptanteil an der Gesamtsteifheit während einer Schwingung stellt die elastische Steifigkeit. Die plastische Steifigkeit erreichte Werte bis zu 40% der Gesamtsteifigkeit bei der Maximalamplitude. Bei kleinen Amplituden war dieCoulombsche Reibungssteifigkeit mit der elastischen Steifigkeit vergleichbar. Die viskose Steifigkeit ist gering.
    Notes: Summary Joint stiffness has been defined in precise physical terms. Methods are described whereby joint stiffness may be measured objectively, qualitatively and quantitatively. Apparatus is described to permit measurements to be made at the knee and the second metacarpophalangeal joints. The major contribution to overall stiffness during a particular oscillation was elastic stiffness. Plastic stiffness was significant (up to 40 per cent at maximum amplitude). At small amplitudesCoulomb frictional stiffness was comparable with plastic stiffness. Viscous stiffness was small.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Rheologica acta 8 (1969), S. 234-239 
    ISSN: 1435-1528
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Zusammenfassung Menschliche Gelenke sind viele Jahre lang untersucht worden. Diese Arbeit berichtet über Untersuchungen, die wesentliche Schmierungseigenschaften vom Standpunkt des Ingenieurs betrachten. Reibungsmessungen dienen dazu, das Auftreten verschiedener Reibungszustände nachzuweisen, wenn Proben von Gelenk-Knorpeln mit einer Synovial-Flüssigkeit geschmiert werden. Dabei erweist sich die Hyaluron-Säure als ein wirksames Grenzschmiermittel. Allerdings wird diese niedrige Reibung in den Gelenken nur erzeugt, wenn ein geschlossener Flüssigkeitsfilm zwischen den gleitenden Oberflächen vorhanden ist. Dieser Film, durch die Gelenke unter geringer Belastung erzeugt, wird durch einen kräftigen Preßfilm-Mechanismus bei starker Belastung, wie sie beim Laufen oder Stehen entsteht, unterstützt. Die Wirksamkeit des Preßfilms hängt von der Welligkeit der Knorpeloberfläche ab (gemessen mit Taststiftmethoden), weiterhin von eingeschlossenen Synovial-Flüssigkeitsmengen, die unter einer Belastungseinwirkung durch einen Filtermechanismus angereichert und gelartig werden.
    Notes: Summary Human joints have been studied for many years, and this paper reports work carried out to investigate their remarkable lubricating qualities from an engineerring aspect. Friction measurements were used to indicate the occurrence of different types of lubrication when using specimens of articular cartilage lubricated with synovial fluid. It was found that hyaluronic acid acted as an efficient boundary lubricant, but that low friction was produced in joints only when there was a full film of fluid between the sliding surfaces. This film, set up by joint movements under light load, would be maintained by a powerful squeeze film mechanism under heavy loads such as endured in walking or standing. The efficiency of this squeeze film depended on the undulations on the cartilage surface, (measured by stylus tracing methods), entrapping pools of synovial fluid which subsequently became enriched and gel-like by a filtration mechanism, under the action of the loads.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 4 (1966), S. 533-542 
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire Pour mieux étudier les propriétés rhéologiques de la peau humaine, on a construit un extensiomètre capable d'étirer des échantillons de peau à une vitesse moyenne constante, à température et degré d'humidité déterminés et enregistrant les résultats sous la forme d'un diagramme tension=f (déformation). Des parties de la courbe ont été attribuées à différentes phases de l'extension. On a adapté des équations empiriques aux différentes phases de l'extension et les constantes tiennent compte des nombreux éléments de la structure de la peau. Les constantes ont été déterminées et comparées suivant l'emplacement, le sexe et l'âge de l'individu.
    Abstract: Zusammenfassung Für die Untersuchungen der rheologischen Eigenschaften der menschlichen Haut wurde ein Extensometer konstruiert, das in der Lage ist, einen Hautbezirk mit konstanter Geschwindigkeit und Temperatur- und Feuchtigkeitskontrolle zu extendieren und die Ergebnisse in Form einer Spannungs-Dehnungskurve aufzuzeichnen. Abschnitte der Kurve wurden verschiedenen Extensionsphasen zugeordnet. Gemäß dieser Extensionsphasen wurden empirische Gleichungen aufgestellt. Die Konstanten wurden verschiedenen Elementen der Hautstruktur zugeordnet. Die Konstanten wurden bestimmt und hinsichtlich der Lage, des Geschlechts und des Alters verglichen.
    Notes: Abstract For the investigation of the rheological properties of human skin an extensometer has been constructed which is capable of extending specimens at a constant rate under controlled temperature and humidity, recording the results in the form of a stress-strain curve. Sections of the curve have been attributed to various phases of extension. Empirical equations have been fitted to these phases of extension, and the constants have been related to various elements of the skin structure. The constants have been determined and compared with regard to site, sex and age.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...