ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 301 (1981), S. 243-254 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Time and pressure dependent recoil into gas measurements of perturbed angular correlations have been carried out following the reactions24, 26Mg+18O. The levels and |g|-values measured are:39K: 2,814 keV, 1.15(12); 3,598 keV, 0.54(5);40K: 2,543 keV, 0.63(15);41K: 2,528 keV, 0.82(19); 2,774 keV, 0.46(7); 4,983 keV, 0.74(30). Meanlives measured for the41K levels are 220(5) ps, 80(2) ps and 106(3) ps, respectively.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 45 (1957), S. 396-404 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Eine neue spezifische Methode zur Mikrobestimmung von Fluoridionen wird angegeben. Diese eignet sich für organische fluorhältige Substanzen nach deren Mineralisierung. Sie beruht auf der wahrscheinlichen Reaktion: 6 F− + 4 H+ + SiO2 +n K+ →* SiF6 2− + 2 H2O +n K+, wonach für je 6 Fluoridionen 4 Wasserstoffionen gebunden werden. Dieser Verbrauch an H-Ionen wird alkalimetrisch gemessen und bietet damit die Grundlage zur Fluorbestimmung. Diese erwähnte Reaktion findet nur in saurem Milieu bei Gegenwart von Kaliumionen statt, ohne daß es zu einer erkennbaren Ausscheidung von Kaliumsilicofluorid kommt. Dem Bruttoergebnis der Bestimmung ist eine Korrektur zuzuzählen, die von dem jeweiligen scheinbaren Fluorgehalt und dem Lösungsmittelvolumen abhängig ist und deren Größe sich aus einem experimentell ermittelten Diagramm ergibt.
    Abstract: Summary A specific micro determination is given for the titrimetric determination of fluoride ions that is susceptible of being associated with a preliminary mineralization of a sample of a fluorine-bearing organic compound with a view of determining in it the fluorine on the micro scale. The fundamental principle is the probable total reaction: 6 F− + 4 H+ + SiO2 +n K+ → SiF6 6−2 + 2 H2O +n K+ which leads to the disappearance of 4 H+ ions from the reaction milieu for each 6 F− ions originally present. This consumption of ions is measured alkalimetrically and the fluorine content can be calculated accordingly. The above reaction occurs only in an acid medium and in the presence of K+ ions without apparent precipitation of potassium fluosilicate. The gross result of the determination must be corrected by an additive function of the apparent content corresponding to the fluorine present and to the volume of the solution. The value of this correction factor may be determined with the aid of a diagram which has been constructed on the basis of trials set up for this purpose.
    Notes: Résumé Les auteurs ont mis au point une méthode spécifique de microdosage titrimétrique des ions F− susceptible d'être associée à une minéralisation préalable d'un échantillon de substance organique fluorée en vue d'y doser le fluor, à l'échelle microanalytique. Le principe en est fondé sur la réaction globale probable: 6 F− + 4 H+ + SiO2 +n K+ -→ SiF6 2 + 2 H2O +n K+, qui donne lieu à la disparition de 4 ions H+ du milieu réactionnel pour 6 ions F− initialement présents. Cette consommation d'ions hydrogènes est mesurée par alcalimétrie et permet ainsi de doser le fluor. La réaction précédente ne se produit qu'en milieu acide, et en présence d'ions K+ sans précipitation apparente de fluosilicate de potassium. Le résultat brut du dosage doit subir une correction additive fonction de la teneur apparente correspondante en fluor et du volume de la solution et dont la valeur peut être déterminée à l'aide d'un diagramme établi expérimentalement.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 50 (1962), S. 224-240 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Verbrennung organischer Fluorverbindungen zur Mikrobestimmung des Fluors im sauerstoffgefüllten Kolben nachSchöniger bzw. in der Flamme eines Knallgasbrenners wurde vergleichsweise untersucht. Anschließend wurde das in wäßriger Lösung vorliegende Fluorid spektrophotometrisch bestimmt. Die photometrische Messung beruht auf der Minderung der optischen Dichte von Eisen(III)-sulfosalicylsäurelösungen beim Zusatz von Fluoridlösungen.
    Abstract: Summary A comparative study was made of the combustion of fluorine compounds for the micro determination of the fluorine in flasks filled with oxygen afterSchöniger as opposed to the flame of an oxy-hydrogen burner. The fluoride in the aqueous receiving solution was then determined spectrophotometrically. The photometric measurement rests on the decrease of the optical density of iron (III) sulfosalicylic acid on the addition of fluoride solutions.
    Notes: Résumé Les auteurs étudient, comparativement, les combustions de composés organiques fluorés, en vue du microdosage du fluor, en fiole remplie d'oxygène, d'aprèsSchöniger, ou dans la flamme d'un microchalumeau oxhydrique d'aprèsLévy. Ils leur associent le dosage par colorimétrie spectrophotométrique en solution aqueuse des ions F− obtenus après la mise en œuvre de l'une ou l'autre des deux méthodes de combustion. La méthode colorimétrique repose sur le principe de la mesure de la diminution de densité optique d'une solution du complexe ferrisulfosalicylique lorsqu'on la mélange à la solution d'ions F− à doser.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Verfasser beschreiben und erörtern fünf bekannte Methoden der Mineralisierung organischer Substanzen zur Bestimmung von Chlor, Brom oder Jod: die Verbrennung in der Knallgasflamme, die Verbrennung in Sauerstoffatmosphäre im leeren Rohr und im Schöniger-Kolben, die Veraschung in der Nickelbombe mit Natriumperoxid und die nasse Verbrennung in Schwefelsäure. Sie verbinden diese Verfahren mit der potentiometrischen Argentometrie der dabei erhaltenen Chlorid- und Bromidionen (mit vorbestimmtem Potential) bzw. der Jodometrie der Jodidionen. Die besten Mineralisierungsverfahren für laufende Bestimmungen sind die Verbrennung in Sauerstoffatmosphäre im leeren Rohr oder die Kolben-Methode; hingegen empfiehlt sich bei Anwesenheit von Heteroelementen, die die Endbestimmung stören, die Veraschung mit Natriumperoxid oder, besser, in Schwefelsäure. Die Verfasser geben genau die Bedingungen für die Anwendung der argentometrischen Titration mit vorbestimmtem Potential oder der jodometrischen Bestimmung in wäßrigen Lösungen an, wie sie bei den verschiedenen Minerali-sierungsverfahren erhalten werden.
    Abstract: Summary Five methods of mineralization of organic compounds are cited and described with regard to determining chlorine, bromine, or iodine in them. They are: oxyhydric combustion; combustion in oxygen, either in a narrow empty tube or in a flask of the Schöniger type; attack in a nickel bomb with sodium peroxide; mineralization in sulfuric acid. The authors combine the foregoing with titration of the resulting ions by potentiometric argentometry (method of adjusted equivalence potentials) for chlorine and bromine, and by iodometry for iodine. The methods of mineralization most interesting for continuous determinations are combustions in oxygen in an empty narrow tube or in a flask though if the presence of heteroelements interferes in the final determination it may be advisable to employ sodium peroxide for the decomposition or better sulfuric acid. The authors state precisely the conditions where the methods of argentometric titration can be applied using the principle of adjusted potentials or iodometric titration in the aqueous solutions obtained from the different methods of mineralization studied by them.
    Notes: Résumé Les auteurs rappellent et décrivent cinq méthodes de minéralisation des composés organiques en vue d'y doser le chlore, le brome ou l'iode: ce sont la combustion «oxhydrique», la combustion dans l'oxygène, soit en tube droit vide, soit en fiole du type «Schöniger», l'attaque en bombe de nickel par le peroxyde de sodium et la minéralisation en milieu acide sulfurique; ils les associent aux méthodes de titrage des ions obtenus par argentométrie potentiométrique (méthode des potentiels d'équivalence repérés) pour le chlore et le brome, et par iodométrie pour l'iode. Les méthodes de minéralisation les plus intéressantes pour les dosages courants sont les combustions dans l'oxygène en tube droit vide ou en fiole tandis que la présence d'hétéroéléments perturbant le dosage final incite à choisir dans ce cas l'attaque par le peroxyde de sodium ou, mieux, la décomposition en milieu acide sulfurique. Les auteurs précisent les conditions d'application des méthodes de titrage argentométrique suivant le principe des potentiels repérés ou de titrage iodométrique dans les solutions aqueuses obtenues après les différentes minéralisations étudiées.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 54 (1966), S. 202-227 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Verfasser berichten vergleichend über vier Methoden zur Mineralisierung organischer Verbindungen, deren Schwefelgehalt bestimmt werden soll, und zwar die Verbrennung in der Knallgasflamme, im Sauerstoffstrom im leeren Rohr, im Schönigerkolben und die reduktive Zerstörung mit Kalium im verschlossenen Röhrchen. Diese Methoden wurden mit der maßanalytischen Bestimmung des Sulfats bzw. Sulfids kombiniert. Daraus ergab sich, daß die Reduktion mit Kalium und die nachfolgende jodometrische Bestimmung des Sulfids am allgemeinsten anwendbar und am sichersten ist.
    Abstract: Résumé Four methods of mineralization of organic compounds are recalled and compared with respect to determining sulfur in them; they are the oxyhydrogen combustion method, combustion in oxygen, in an empty tube, or in a flask of the Schöniger type, and the reductive mineralization in a sealed tube by potassium. They are combined with the titration methods for the SO4 2− or S2− ions. This study has enabled the authors to select the reductive method of mineralization by means of potassium followed by the iodometric titration of S2− ions as the most general and most reliable among the various procedures.
    Notes: Résumé Les auteurs rappellent et comparent quatre méthodes de minéralisation des composés organiques en vue d'y doser le soufre: ce sont la méthode de combustion oxhydrique, la combustion dans l'oxygène, soit en tube droit vide, soit en fiole du type «Schöniger» et la minéralisation réductrice en tube scellé par le potassium. Ils les associent aux méthodes de titrage des ions SO4 2− ou S2−. Leur étude leur permet de sélectionner parmi les méthodes décrites la minéralisation réductrice par le potassium associée au titrage iodométrique des ions S2− comme la plus universelle et la plus sûre d'entre elles.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 36-37 (1951), S. 741-768 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Eine der einfachsten und raschesten Methoden der Veraschung organischer Substanzen für die Bestimmung der Halogene ist ohne Zweifel die mit Natriumperoxyd in derParr-Bombe. Es scheint zweckmäßig, sie mit einem ebenso zufriedenstellenden Verfahren für die eigentliche Halogenbestimmung zu kombinieren. Die Gravimetrie der Silberhalogenide ist langwierig und mißlich und deren Umrechnungsfaktoren insbesondere für Brom und Jod recht ungünstig. Die argentometrische Maßanalyse ist entweder schwierig oder gar nicht durchführbar in Gegenwart hoher Salzkonzentrationen. Im Halbmikromaßstab lassen sich Chlor und Brom mittels 0,02-n-Silbernitratlösung und Verwendung einer Makrobürette potentiometrisch titrieren. Hohe Salzkonzentration verhindert jedoch nach dem üblichen Verfahren den Übergang zum Mikromaßstab; im übrigen ist auch dieses Verfahren relativ langwierig. Die vom Verfasser angewendete Methode der gekennzeichneten Gleichgewichtspotentiale ermöglicht die maßanalytische Bestimmung der Chlorionen mittels 0,01-n-Silbernitrat, der Brom- und Jodionen mittels 0,002-n-Silbernitrat, wobei für diese Lösungen Halbmikrobüretten verwendet werden. Der niedere Titer der angewendeten Silberlösung läßt diese Methode der Jodbestimmung dem Multiplikationsverfahren mit 0,01-n-Thiosulfat gleichwertig erscheinen. Sie ist im übrigen viel rascher ausführbar als sonst übliche volumetrische und auch potentiometrische Methoden und läßt sich, kombiniert mit demParr-Verfahren, zur Serienbestimmung verwenden.
    Abstract: Summary One of the most simple and most rapid methods of mineralizing organic compounds for the purpose of determining halogens is doubtless the attack of these materials by sodium peroxyde in theParr microbomb. A method having comparable qualities for the subsequent determination of the halogens thus mineralized is described here. The gravimetric determination of silver halide precipitates is long and delicate, and the factors become unfavorable for bromine and especially for iodine. The argentometric volumetric methods are made difficult or impossible because of the high concentration of salts in the halide solutions. Potentiometric argentometry provides a method of determining chloride and bromide on a semi-microanalytical scale by means of 0,02 N silver nitrate solution added from a macroburette. When the usual potentiometric method is employed, the high concentration of salts does not permit determinations on the microanalytical scale; furthermore this method still requires a considerable expenditure of time. The method of equivalence potentiale, used by the author, permits the determination, on the microanalytical scale, of chloride with 0,01 N silver nitrate solution, and of bromide and iodide with 0,002 N silver nitrate. These solutions are measured in a semi-microburette. The low titre of the silver nitrate solution used allows this method to compete for iodide, with the iodometric method (when 0,01 N sodium thiosulfate is used) where six equivalents are titrated for each equivalent being determined. Moreover, the present method is faster then the other volumetric methods including the ordinary potentiometric method, and lends itself, like the mineralization in the microbomb, to series determinations.
    Notes: Résumé Une méthode des plus simples et des plus rapides de minéralisation des composés organiques en vue du dosage des halogènes est sans aucun doute l'attaque de ces substances par le peroxyde de sodium dans la microbombe deParr. Il convenait de lui associer une méthode ayant des qualités comparables pour le dosage ultérieur des halogènes ainsi minéralisés. La gravimétrie des précipités d'halogénures d'argent est longue et délicate et les facteurs de calcul deviennent défavorables pour le brome et surtout pour l'iode. Les méthodes volumétriques argentométriques sont rendues difficiles ou impossibles du fait de la haute concentration en sels des solutions d'ions halogènes. L'argentométrie potentiométrique a permis de doser à l'échelle semimicroanalytique les ions chlore et brome avec une solution de nitrate d'argent 0,02 N mesurée dans une macroburette. La haute concentration en sels ne permet pas, lorsqu'on utilise la méthode potentiométrique habituelle, de faire des dosages à l'échelle microanalytique; en outre cette méthode est encore de durée relativement longue. La méthode des potentiels d'équivalence repérés utilisée par l'auteur permet les dosages à l'échelle microanalytique de l'ion chlore avec une solution de nitrate d'argent 0,01 N, et des ions brome et iode avec une solution de nitrate d'argent 0,002 N, ces solutions étant mesurées dans une semi-microburette. Le faible titre de la solution de nitrate d'argent employée permet à cette méthode de concurrencer, pour l'iode, la méthode iodométrique au thiosulfate de sodium 0,01 N où l'on dose 6 équivalents d'iode pour un seul à déterminer. Cette méthode est, en outre, beaucoup plus rapide que les autres méthodes volumétriques y compris la méthode potentiométrique habituelle, et se prête, comme la minéralisation à la microbombe, aux dosages en grande série.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 44 (1956), S. 906-924 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die seinerzeit beschriebene Methode zur Mikrobestimmung yon Chlorund Brom durch Silbernitrattitration mit vorbestimmtem Potential nach vorhergehender Zerstörung des organischen Materials mit Natriumperoxyd wurdefür die gleichzeitige Anwesenheit der beiden Halogene erweitert. Das hier beschriebene Verfahren beinhaltet zwei Bestimmungen in zweiEinwaagen veto Gewicht µ1 bzw. µ2 mg. Die erste Bestimmung, ausgeführtmit einer Einwaage yon etwa 5 mg, ergibt ein Volumen yonq ml der verbrauchten 0,01-n Silbernitratlösung, das der Summe der beiden Halogene#x00E4;quivalent ist. Der Endpunkt der Titration wird durch Einstellung desPotentials einer Silberelektrode erhalten, das den Bedingungen der Chlormikrobestimmung entsprieht. Die zweite Bestimmung, ausgeführt mit einerEinwaage von etwa 2 bis 3 mg, ergibt das nicht korrigierte Volumenu ′ an0,002-n Silbernitratlösung, das dem Bromgehalt äquivalent ist. Der Endpunkt der Titration wird durch Einstellung des Potentials einer Silberelektrode erhalten, das den Bedingungen der Mikrobestimmung von Bromallein entspricht. Das nicht korrigierte Volumenu ′ der 0,002-n Maβlösung,das dem Chlorgehalt der zweiten Einwaage entspricht, ergibt sieh aus der Gleichung: $$\upsilon ' = \left( {5 \cdot \frac{{\mu _2 }}{{\mu _1 }} \cdot q - u'} \right)ml.$$ Die Voluminau und υ der 0,002-n Maβlösung, die dem Brom- bzw. Chlorgehalt in der Einwaage µ2 tatsächlich äquivalent sind, erhält man aus den Beziehungen: $$u = \left( {u' - \varepsilon _{Br} } \right)mlund\upsilon = \left( {\upsilon ' + \varepsilon _{Br} } \right)ml.$$ ∈Br ist eine von der verwendeten Menge Natriumperoxyd (3 g), von derArt der zur Neutralisation und zum Ansäuern verwendeten Säure (H2SO4) und vom Endvolumen der Lösung bei der Bromtitration (200 ml) abhängige Korrekturgröβe. Im allgemeinsten Fall (0,5 ≦u≦10 ml-1≦υ≦10 ,ml) läβt sich ɛBr aus folgender empirischer Gleichung errechnen. $$\varepsilon _{Br} = \frac{{\left( {0,072\upsilon ' + 0,144} \right) log_{10} \left( {3 + u'} \right) - \left( {0,02\upsilon ' + 0,088} \right)}}{{1,02 - 0,072 log_{10} \left( {3 + u'} \right)}}$$ Diese kann man im übrigen in bestimmten Grenzfällen extrapolieren. Der gesuchte Gehalt an Chlor und Brom ergibt sich aus den Gleiehungen: $$Br \% = \frac{{15,9832 u}}{{\mu _2 }}Cl \% = \frac{{7,0917\upsilon }}{{\mu _2 }}$$ Die Genauigkeit der Resultate ist jener vergleichbar, die man für Chlor oderBrom allein erhält. Der mittlere absolute Fehler ist für Br von der Gröβenorchmng ± 0,15%, für Chlor ± 0,20%.
    Abstract: Summary The method previously described for the microdetermination of chlorineand bromine by argentometry by reference potentials combined with preliminary mineralization of organic compounds by means of sodium peroxidehas been extended to the case in which both halogens are present. Themethod in general involves two determinations conducted on two separatesamples weighing respectively µ1 and µ2 mg. The first is made on the sample µ1 (about 5 mg) with silver nitrate(0.01N). It gives the volumeq ml of reagent that is equivalent to the sumof the two halogens. The endpoint of the titration is determined by referenceto the potential of a silver electrode under the equivalence conditions of themierodetermination of chlorine. The second titration is made with the sample µ2 (about 2 to 3 mg) with0.002N silver nitrate. It gives the volumeu ′ (uncorrected) of reagent equivalentto the bromine. The endpoint is determined by reference to the potentialof a silver electrode under the equivalent conditions of the microdeterminationof brominealone. The volume υ′ (uncorrected) of reagent (0.002N) equivalent to the chlorinein the sample µ1 is given by the expression: $$\upsilon ' = \left( {5\frac{{\mu _1 }}{{\mu _2 }}q - u'} \right) ml.$$ The volumes of 0.002N reagent,u and υ, actually equivalent to thebromine and chlorine contained in the sample µ2 are obtained from therelations: $$u = \left( {u' - \varepsilon _{Br} } \right) ml\upsilon = \left( {\upsilon ' + \varepsilon _{Br} } \right) ml.$$ ɛ Br is the correction to be applied. Its value depends on the amountof sodium peroxide used (3 grams), the nature of the acid used for the neutralization and acidification of the solution (sulfuric acid), and the finalvolume in which the bromine is titrated (200 ml). In the most general case[0.5〈u〈10ml-l〈υ〈10ml] ɛ Br can be calculated from the empirical equation: $$\varepsilon _{Br} = \frac{{\left( {0.072 \upsilon ' + 0.144} \right) log_{10} \left( {3 + u'} \right) - (0.02\upsilon ' + 0.088}}{{1.02 - 0.072 log_{10} \left( {3 + u} \right)^\prime }}$$ This expression is capable of extrapolation into certain limiting regions. The content of chlorine and of bromine desired are obtained by meansof the expressions: $$\% Br = \frac{{15.9832 u}}{{\mu _2 }}\% Cl = \frac{{7.0917 \upsilon }}{{\mu _2 }}$$ The precision of the results is comparable to that obtained from separatedeterminations of the halogens. The mean absolute error is of the order of±0.15% for bromine and ±O.20% for chlorine.
    Notes: Résumé La méthode antérieurement décrite de microdosage du chlore ou du brome par argentométrie par potentiels repérés couplée à la minéralisation préalable des composés organiques par le peroxyde de sodium a été étendue au cas de la présence simultanée des deux halogènes. Elle comporte alors, en général, deux déterminations effectuées sur deux prises d'essais distinctes pesant respectivementμ 1 etμ 2 mg. La première est effectuée sur la prise d'essaiμ 1 (environ 5 mg) avec du nitrate d'argent 0,01 N; elle fournit le volumeq ml de réactif équivalent à la somme des deux halogènes; le point final de titrage est déterminé par repérage du potentiel d'une électrode d'argent dans les conditions d'équivalence du microdosage du chlore. La seconde est effectuée sur la prise d'essaiμ 2 (environ 2 à 3 mg) avec du nitrate d'argent 0,002 N; elle fournit le volumeu′ non corrigé de réactif équivalent au brome; le point final de titrage est déterminé par repérage du potentiel d'une électrode d'argent dans les conditions d'équivalence du microdosage du bromeseul. Le volumev′ non corrigé de réactif 0,002 N équivalent au chlore, dans la priseμ 2 est fourni par l'égalité: $$\upsilon ' = \left( {5\frac{{\mu _2 }}{{\mu _1 }}q - u'} \right)ml.$$ On obtient les volumesu etv de réactif 0,002 N réellement équivalents au brome et au chlore contenus dans la priseμ 2 d'après les relations $$u = \left( {u' - \varepsilon _{Br} } \right)ml\left( {\upsilon = \upsilon ' + \varepsilon _{Br} } \right)ml.$$ ɛ Br est une correction qui dépend de la masse de peroxyde de sodium employée (3 grammes), de la nature de l'acide utilisé pour la neutralisation et l'acidification de la solution (acide sulfurique) et du volume final de titrage du brome (200 ml). Dans le cas le plus général [0,5≦u≦10 ml — 1≦v≦10 ml] ɛBr peut se calculer d'après l'équation empirique suivante: $$\varepsilon _{Br} = \frac{{\left( {0,072\upsilon ' + 0,144} \right) log_{10} \left( {3 + u'} \right) - \left( {0,02\upsilon ' + 0,088} \right)}}{{1,02 - 0,072 log_{10} \left( {3 + u'} \right)}}$$ qui est d'ailleurs susceptible d'être extrapolée dans certains domaines limitrophes. Les teneurs en chlore et en brome cherchées s'obtiennent à partir des formules: $$Br \% = \frac{{15,9832 u}}{{\mu _2 }}Cl \% = \frac{{7,0917 \upsilon }}{{\mu _2 }}.$$ La précision des résultats est comparable à celle que l'on obtient pour chacun des halogènes seuls; l'erreur absolue moyenne est de l'ordre de grandeur de±0, 15% pour le brome et de±0, 20% pour le chlore.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 48 (1960), S. 854-862 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Bei dem Verfahren vonShelberg bzw.Schöniger zur raschen Bestimmung des Stickstoffes nach dem Prinzip vonDumas wurden verschiedene Verbesserungen ausgearbeitet, womit mehrere Fehlerquellen ausgeschaltet, die Anwendbarkeit des Verfahrens erweitert und seine praktische Ausführung erleichtert wurden.
    Abstract: Summary The authors have made some improvements in theShelberg andSchöniger rapid micro method of determining nitrogen based on theDumas procedure. Several sources of systematic errors have been eliminated, the range of the method has been widened, and the manipulations have been made easier.
    Notes: Résumé Les auteurs ont apporté diverses améliorations à la technique deShelberg etSchöniger de microdosage rapide de l'azote d'après le principe deDumas. Elles ont permis d'éliminer plusieurs causes d'erreurs systématiques, d'augmenter l'universalité de la méthode et de faciliter les manipulations.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Mycopathologia 87 (1984), S. 167-170 
    ISSN: 1573-0832
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract Enzyme linked immunosorbent assay was found to be a convenient method for the investigation of antibodies in mice immunized with Candida albicans ribosomes. Antibodies against the ribosomal antigen were detected in all the sera of mice (ICR and BALB/ c) immunized with ribosomes and incomplete Freund's adjuvant and in some of the sera of mice immunized with ribosomes only; the titer of antibodies varied from 1∶320 to 1∶10 240. Vaccination of mice with ribosomal protein and IFA resulted in a high titer of antiribosomal antibodies. Treatment of ribosomes with pronase abrogated the capacity of the ribosomes to elicit anti ribosomal humoral responses, suggesting that the antibodies detected were directed against the protein moiety of the ribosomes. The presence of antibodies in sera of immunized mice could not be correlated with the protection afforded by the ribosomal vaccination.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 17 (1995), S. 1247-1254 
    ISSN: 0392-6737
    Keywords: Nonlinear optics ; Time-resolved optical spectroscopies and other ultrafast optical measurements in condensed matter ; Conference proceedings
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Summary We present wave-mixing techniques which are used to determine the tensor elements of the non-linear dielectric susceptibility, the dynamics of non-linear optical effects and the transport properties of a material. These techniques are applied to CdS nanocrystallites, prepared in a SiO2 matrix by a sol-gel method. They were prepared as thin films of variable density (up to 30% of volume). By the same experimental techniques, porous silicon is studied and the results are compared to those obtained from luminescence and time-of-flight measurements.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...