ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • INSTRUMENTATION AND PHOTOGRAPHY  (228)
  • Physics  (171)
  • ASTRONOMY
  • EARTH RESOURCES AND REMOTE SENSING
  • 1970-1974  (455)
Collection
Publisher
Years
Year
  • 1
    Publication Date: 2019-07-13
    Description: Recent technological developments have enabled application of the techniques of radio astronomy to problems of earth and ocean physics. To illustrate these applications, we review results from the 19.35 GHz Electrically Scanned Microwave Radiometer (ESMR) now in operation on Nimbus 5. A composite image of the earth made from ESMR observations taken between January 12 and January 16, 1973 illustrates the wide range of physical effects in single channel microwave observations. Multi-frequency observations made from aircraft have demonstrated an even greater potential for satellite radiometry when several frequencies and polarizations are used simultaneously. As an illustration of the considerations required in multi-channel radiometry, we discuss the choice of frequencies for the Scanning Multichannel Microwave Radiometer (SMMR) planned for the Nimbus G satellite.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: International Convention and Exposition; Mar 26, 1974 - Mar 29, 1974; New York, NY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science Part A-1: Polymer Chemistry 10 (1972), S. 259-273 
    ISSN: 0449-296X
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: By means of bromine labeling and ESR, the grafting reactions of styrene onto preirradiated polyethylene have been investigated. Not all the radicals produced by irradiations participate in grafting reactions all together, but they are rendered active bit by bit by the swelling of crystalline parts of polyethylene. The growing rates for polystyryl graft chains at 20°C decrease from 4 monomer units/active site/sec to one-fourth the initial value after 100 min. On the contrary, the average lifetimes increase from 〈103 sec to 〉2.6 × 103 sec. The number-average molecular weight of graft chains also increases with reaction times and rises to 3.5 × 105 after 90 min at 20°C.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-08-16
    Description: Synoptic views of the entire polar regions of earth have been obtained free of the usual persistent cloud cover using a scanning microwave radiometer operating at a wavelength of 1.55 cm on board the Nimbus-5 satellite. Three different views at each pole are presented utilizing data obtained at approximately one-month intervals from December 1972 to February 1973. Large discrepancies exist between the long-term ice cover depicted in various atlases and the actual extent of the canopies. The distribution of multiyear ice in the north polar region is markedly different from that predicted by existing ice dynamics models. Irregularities in the edge of the Antarctic sea ice pack occur that have neither been observed previously nor anticipated. The brightness temperatures of the Greenland and Antarctic glaciers show interesting contours probably related to the ice and snow morphologic structure.
    Keywords: EARTH RESOURCES AND REMOTE SENSING
    Type: American Meteorological Society; vol. 55
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2016-06-07
    Description: In order to demonstrate the feasibility of the microwave radiometers to be carried aboard the Nimbus 5 and 6 satellites and proposed for one of the earth observatory satellites, remote measurements of microwave radiation at wavelengths ranging from 0.8 to 21 cm have been made of a variety of the earth's surfaces from the NASA CV-990 A/C. Brightness temperatures of sea water surfaces of varying roughness, of terrain with varying soil moisture, and of sea ice of varying structure were observed. In each case, around truth information was available for correlation with the microwave brightness temperature. The utility of passive microwave radiometry in determining ocean surface wind speeds, at least for values higher than 7 meters/second has been demonstrated. In addition, it was shown that radiometric signatures can be used to determine soil moisture in unvegetated terrain to within five percentage points by weight. Finally, it was demonstrated that first year thick, multi-year, and first year thin sea ice can be distinguished by observing their differing microwave emissivities at various wavelengths.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: 4th Ann. Earth Resources Program Rev., Vol. 1; 19 p
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science Part A-2: Polymer Physics 8 (1970), S. 595-603 
    ISSN: 0449-2978
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The adsorption of tritium-labeled sodium stearate and 35S-labeled sodium dodecylsulfate from aqueous solution on bent and on stretched polyethylene strips was directly measured. The amount of adsorption increased from 2.5 to 4.5 times on surfaces of various polyethylene samples stretched from 5.2 to 5.3 times the original length. For one sample, adsorption increased 8 and 2.5 times, respectively, on the convex and concave surfaces of a bent strip. Autoradiographs of the strips taken after adsorption revealed the appearance of both homogeneous and heterogeneous adsorption on the stretched surface of the polyethylene. The electron micrographs of the strips showed that many small fissures, about 1-5μ in length, formed on their surfaces after the strips were bent or stretched. Enhanced adsorption of the surface-active substance along these fissures was suggested. On the basis of these observations, it is proposed that in stretching or bending, fissures increase adsorption of the detergent, and the adsorption in turn promotes further development of fissures. Thus, bending and adsorption mutually promote the growth of fissures which finally result in failure of the polyethylene.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science Part A-2: Polymer Physics 8 (1970), S. 1195-1209 
    ISSN: 0449-2978
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The strain-optical coefficient and relaxation modulus were simultaneously measured for high-density polyethylene at various temperatures ranging from 12 to 100°C. Not only horizontal but also vertical shifts were necessary to obtain smooth master curves by the application of time-temperature superposition. However, the relaxation modulus decreases with rising temperature while the strain-optical coefficient increases. This behavior indicates that the variation of the relaxation modulus and the strain-optical coefficient with time can not be explained by a decrease in crystallinity with rising temperature since a decrease in crystallinity usually causes a decrease in the strain-optical coefficient with time can not be explained by a decrease in crystallinity with rising temperature since a decrease in crystallinity usually causes a decrease in the strain-optical coefficient. It was emphasized that another explanation should be sought for the vertical shift in the time-temperature superposition of the time-dependence curves of the relaxation modulus and the strain-optical coefficient at various temperatures. The master curve of the strain-optical coefficient at various temperatures. The master curve of the strain-optical coefficient or the optical distribution function of relaxation times determined from it serve to distinguish the type and thermal history of the polyethylene.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science Part A-2: Polymer Physics 10 (1972), S. 1085-1095 
    ISSN: 0449-2978
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: In order to study the crazing behavior in rubber-toughened glassy polymers, polystyrene samples containing two rubber balls of the same diameter with varying separations have been prepared. They were subjected to simple tension, and their crazing behavior was observed. When the two balls are close together, the craze-initiation stress is considerably lower than that of single-ball samples. With increase in the distance between the two balls the craze-initiation stress increases at first almost linearly and levels off when l/d reaches about 1.45, where l and d are the center-to-center distance and the diameter of the balls, respectively. When l is sufficiently small, the crazes are seen to develop extensively at the inner surfaces of the balls and finally bridge with each other. The crazes bridged between the balls expand largely in the plane perpendicular to the applied load.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science Part A-2: Polymer Physics 10 (1972), S. 193-200 
    ISSN: 0449-2978
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Recent literature reports from three laboratories have treated the refraction correction for the Sofica and a noncommercial light scattering photometer. Our re-evaluation of the data contained in these reports, as well as our experiments, indicate that the usually cited n2 refraction correction has not been unquestionably established for these instruments. In some cases, imprecise experimental techniques have been used to support this particular form of the correction. In addition, we find the optical system of the Sofica instrument results in the detector seeing vertically past the horizontal edge of the illuminated volume in violation of a basic assumption in the deduction of the n2 correction. Our experiments, as well as our interpretation of recent literature data, support an exponent of less than 2.0 for the Sofica apparatus, which is consistent with an instrument whose detector views outside the illuminated volume. However, the experimental methods available to evaluate the exponent lack the desired precision.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science Part A-2: Polymer Physics 10 (1972), S. 569-570 
    ISSN: 0449-2978
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science Part A-2: Polymer Physics 8 (1970), S. 1211-1225 
    ISSN: 0449-2978
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: To determine the true reason for the increase in birefringence and the decrease in relaxation modulus for high-density polyethylene with rising temperature, changes in crystalline structure as well as in thermal, viscoelastic, and rheo-optical properties with temperature were measured, by several techniques, including DSC, DLI, infrared dichroism, x-ray diffraction, and NMR. The values for degree of crystallinity obtained from the DSC fusion curve, density, and infrared absorbances coincide very well and show almost no divergence till about 80°C. The optical vertical shift factor pT can be related to the ratio of the orientation function for the crystal c axis at an arbitrary temperature to that at the references temperature, fε/fε0. The mechanical vertical shift factor bT, on the other hand, is associated with the temperature dependence of the mobile fraction, as determined by NMR measurements, but not with variations in degree of crystallinity.
    Additional Material: 17 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...