    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 6 (1972), S. 59-79 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Advantages of a hollow-fiber hemodialyzer have been well described. The goal of this program was to provide a working model of a noncellulosic hollow fiber artificial kidney with nonthrombogenic blood-contacting surfaces, low blood-priming volume and low pressure drop, a satisfactory rate of urea transport, and high rate of ultrafiltration of water. Also, the reliability and utility of these devices was to be demonstrated through clinical evaluation.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 6 (1972), S. 405-441 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Porcelain inlays coupled by a silane treatment to composite resins which were used as cementing media and in turn retained by an undercut were evaluated as to their marginal integrity and retention against conventionally restored teeth. These included restorations in teeth with undercuts of resins, composites, and porcelain inlays cemented with zinc oxyphosphate cements.The evaluations were determined by isotope penetration during thermal cycling (180 cycles from 12 to 50°C), scanning electron microscopy of sectioned restorations, and mechanical pull tests.The results showed improved retentive qualities and markedly improved resistance to marginal penetration. Improved adaptation of the composite to the tooth surface was produced by the mechanical action of seating the porcelain inlay.
    Additional Material: 29 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 8 (1974), S. 49-64 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A series of nonporous glasses and glass materials designed with controlled surface ion activities to allow chemical bonding to bone are described. Surface reactivities of these materials in vitro are correlated with biological activities in vivo and in tissue culture. Direct chemical bonding of the materials to bone is demonstrated. The mechanism for development of this bond is through the production of an amorphous ion surface gel on the bioglass. This gel induces osteogenesis by a chemotactic response of osteoblasts.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 4 (1970), S. 145-187 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The influences of the conditioning treatments, surface topography, and crystal structure of carbonaceous surfaces on their ability to sorb heparin and their in vivo compatibility with blood were investigated. The results of the sorption studies indicated that the adsorption of heparin on the surfaces of turbostratic and graphitic materials is not crystallographically selective and that the amount adsorbed on relatively smooth surfaces is near the amount expected for monolayer formation. Although the adsorption of heparin on relatively smooth carbon surfaces is not influenced by the presence of benzalkonium chloride, the sorption of heparin in porous carbons can be greatly increased by a pretreatment with benzalkonium chloride. This increase was found to be due to the formation and entrapment of the insoluble heparin-benzalkonium complex in the accessible porosity. Since the heparin sorptions in Dag-154 coatings were found to be enhanced by a pretreatment with benzalkonium chloride, it was inferred that these coatings contain accessible porosity and that their initial thromboresistance depends on the formation of the benzalkonium-heparin complex in pores. In vivo tests showed that polished and outgassed, impermeable isotropic carbons deposited at low temperatures were significantly thromboresistant without the exogenous application of heparin. There was no relationship between the amount of heparin sorbed on these materials and their compatibility with blood. Polishing, for example, which reduced heparin sorption, enhanced the thromboresistance of these carbons, and while chemisorption of oxygen markedly reduced their thromboresistance, it did not influence the amount of heparin that could be sorbed. Although the heparin-benzalkonium complex sorbed in a porous carbon conferred excellent thromoboresistance in a 2-hr test, the long-tern (14-day) compatibility was not as good as for carbon surfaces that were deposited at low temperatures and then polished and outgassed prior to implanting. In vivo tests of HTI carbon structures and annealed LTI carbons indicate that the blood compatibility of a turbostratic carbon is not significantly dependent on crystallite size, Le. Limited tests of surfaces that had a preponderance of c-faces oriented parallel to the blood-carbon interface at the surface suggest that orientations of this sort are better than others.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 4 (1970), S. 275-277 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Autoclave sterilization of paper-wrapped stainless steel implants resulted in slight general surface corrosion and crystalline contamination. Such artifacts may produce microanodes which induce local tissue reactions, thereby lowering the pH and further activating the corrosion process. Implants sterilized in ethylene oxide or benzalkonium chloride did not show artifact corrosion or contamination. Mechanisms are presented to show the effects contaminants have upon both the corrosion behavior and the tissue reaction of implant materials.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 7 (1973), S. 401-418 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Scanning electron micrographs were made of the surfaces of silicone rubber finger joint prostheses which had been subjected to 107 bending cycles at 37°C in bovine serum. Preferential attack at the regions of highest stress and the formation of microcracks of length 10μ and less were observed. By way of analogy with the corrosion fatigue phenomenon in metallic alloys, it is suggested that these may be initiation sites for the mechanical failures which have been observed, and that the acceleration of lipid absorption by tensile stress provides potential mechanisms for both initiation and accelerated propagation of fatigue cracks. It is demonstrated as a consequence of mechanochemical thermodynamics that any constituent of the body fluids (e.g. lipids) which can swell the elastomer will in fact be preferentially absorbed at the point of highest tensile stress, i.e., the crack tip, and that swelling will be accelerated by the applications of tensile stress.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 5 (1971), S. 105-127 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Flexible and rigid epoxy and urethane polymers containing heparin chemically and uniformly incorporated throughout and/or ionically complexed to quaternized amine grops were prepared and shown to have excellent thromboresistance in vitro and in vivo. These heparin-modified polymers were implanted into the vena cava of dogs and successfully passed multiple acute (2 hr) and chronic (2 week) exposure periods. It was also demonstrated that the chemically coupled heparinized epoxies had no measurable adverse effects on blood cells, platelets, or plasma proteins, and that the heparin was not extractable. Significantly, epoxies containing polyoxypropylene/polyoxyethylene glycol (an additive which had no thrombus-inhibiting properties of its own) also exhibited excellent thromboresistance when characterized in vivo in dogs. The applicability of these various materials for the fabrication of circulatory assist device components was demonstrated. The effect of polymer polarity, surface charge, and conductivity were investigated with indeterminate results and unmodified commercial polymers uniformly exhibited poor clotting characteristics. In vitro clot-inhibiting characteristics were shown to be a sufficient, but not necessary, condition for indicating in vivo thromboresistant activity in polymer systems.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 5 (1971), S. 117-141 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The development of a bone-bonding calcia-phosposilicate glass-ceramic is discussed. A theoretical model to explain the interfacial bonding is based upon in-vitro studies of glass-ceramic solubility in interfacial hydroxyapatite crystallization mechanisms, compared with in-vivo rat femur implant histology and ultrastructure results.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 8 (1974), S. 375-379 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A polyelectrolyte synthesized from cis-1,4-polyisoprene, containing aminosulfonate and carboxylate groups was shown to have an anticoagulant activity of about 1/30 compared with heparin. Because the substance prevents the coagulation of plasma in the presence of thrombin it is assumed that it acts as an antithrombin.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 6 (1972), S. 413-423 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The effect of surface contamination on the morphology and orientation of poly-L-alanine on a glass-ceramic and the (1010) and (1011) crystal faces of L-quart is dealt with both microscopically and graphically. “Cleaning” with an r. f. plasma cleaner and contamination with pure nitrogen results in a change in the number of active sites with a corresponding change in the relative orientation of the polymer and the strength of bonding.