ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chemical Engineering  (140)
  • Gas chromatography  (13)
  • Wiley-Blackwell  (153)
  • 1975-1979  (153)
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 25 (1979), S. 885-890 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 18 (1978), S. 660-667 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The operation of a twin screw extruder processing a powder or granular solid is reviewed. The operating variables of screw speed and barrel temperature profile interact with a number of design parameters -  screw design, die geometry, feed zone geometry and with the material properties, in determining machine performance. The factors that determine output and pressure development are specified in a sequence of block diagrams. The dynamic response of an operating machine to disturbances in the steady state conditions is explained in the light of the established relationships and interpreted in conventional control theory terms. Attention is drawn to the importance of mixing in the chambers formed by the screw channels and of the residence time distribution in determining the quality of the final product.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 22 (1976), S. 1156-1156 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 24 (1978), S. 354-357 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 22 (1976), S. 1090-1096 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The presence of internal circulation in forming liquid drops has a significant effect on mass transfer rates. For the systems studied, no circulation was observed below a Reynolds number of 9.7. For Reynolds numbers between 9.7 and 34.4, transition from zero circulation to complete circulation during the entire drop formation period occurred. In studies on the rate of mass transfer from fixed volume drops with forced internal circulation, increases in mass transfer rates were found at Reynolds numbers which corresponded to those observed for the development of internal circulation patterns within the drop.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 18 (1978), S. 299-305 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: One of the problems to be considered in the application of the Halpin-Kardos theory to crystalline polymers is the relation of the crystal length to the only related and measurable parameter, spherulite size. The number average crystal length has been computed for various two and three dimensional models for the crystallization process assuming heterogeneous nucleation. It was found that high values of crystallinity are consistent only with lamellae that are stacked in a parallel fashion. For these systems the number average lamellar length is 0.55 of the spherulite radius. Lower crystallinity polymers have an average lamellar length 0.3 to 0.5 of the spherulite radius, the actual value being determined by the radius. For spherulites of radius 1μm or greater, the size of the primary nucleus has no noticeable influence on the average lamellar length.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 18 (1978), S. 869-874 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The effect of time of indentation and time of recovery on the Rockwell hardness, of a series of glassy and crystalline polymers has been determined. An analytical technique, based on conventional viscoelastic approaches, has been developed. This technique permits the resolution of the hardness number into its components of permanent deformation, retarded elastic compression, and retarded elastic recovery. Subtraction of components due to retarded elastic response results in hardness numbers dependent only the time-dependent permanent deformation. Extrapolation of this data to zero time results in an absolute or time-independent value of Rockwell hardness, designated Ro.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 288-292 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Stationary phases, polar, gum type ; For temperatures up to 300°C ; For most of the common classes of organic compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Most of the common classes of organic compounds chromatograph normally on Superoxes. There is no tailing or adverse effect from excessively different activity different activity coefficients. Superoxes are therefore universal phases for gas chromatography. This is also expressed by a wide useful temperature range from ∼50° to ∼300°. High MW Superox-4 has a MAOT about 20° higher than the lower MW Superox-0.1. Several applications illustrating the versatility of Superox phases in (GC)2 are presented.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 283-287 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Sampling technique ; Semi-automation of head space sampling ; Application to water pollution, coffee aroma, light hydrocarbons in crude oil ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Head space GC using a special electropneumatic sampling system works well in combination with glass capillaries. Because a homogenous gas mixture is already present most problems inherent with inlet splitters are thus avoided. In cases where the high vapor pressure of the sample can cause problems with the pressure controlled sampling system, the use of narrow bore glass capillaries provides the necessary inlet pressure. The use of this powerful and convenient analytical tool for water pollution analysis, flavour analysis and the analysis of volatiles in crude oil samples is shown by examples.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 487-496 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Comparison of FID, ECD, FPD for detection limit. linearity, peak shape etc. ; Practical results for pesticide residue and coal hydrogenation products given ; Concentration dependent detectors in capillary GC interesting, when optimized ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A comparison of the characteristics and Performance of the flame ionization, electron capture, and flame photometric detectors with capillary columns is described. Factors which may affect the limits of detection, linearity, chromatographic peak shape, and other detector performance characteristics are discussed and compared with the results of a model derived for the behavior of concentration and mass flow-rate dependent chromatographic detectors used with capillary GC systems. Examples are given of highly complex and labile mixtures such as pesticide residues and products from coal hydrogenation.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗