ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Inorganic Chemistry  (2)
  • HCl, Metall-Standardlösung, Standardzugabeverfahren  (1)
  • R/V Vereshchagin
  • pollen analytical standard techniques
  • 1975-1979  (2)
  • 1940-1944  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 298 (1979), S. 358-362 
    ISSN: 1618-2650
    Keywords: Best von Kryptanden, Kryptaten ; Volumetrie ; HCl, Metall-Standardlösung, Standardzugabeverfahren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Using bromocresol green as a visual endpoint indicator solutions of the cryptands [2.2.1] and [2.2.2] can be determined by titration with HCl in the concentration range of 10−1–10−3 M with relative standard deviations of 0.2–0.4 %. If both cryptand and cryptate are present in one solution, then the sum of them can be determined titrimetrically in the same way. It is also possible to determine the contents of [2.2.1] and [2.2.2] by using a calcium or barium standard solution and the unknown cryptand solution as a titrant. By evaluation of the pH-curve thus obtained, the endpoint of the titration can be determined. In the concentration range of 10−1–10−2 M relative standard deviations of about 0.5% are obtained. [2.2.1] cryptand solutions are determined by using the standard addition technique of Gran with a calcium chloride solution. An ion-selective electrode is used as a probe for calcium ions. If this method is applied, the relative standard deviation in the range of 10−2–10−4 M solutions is approximately 3%. With this technique cryptand can be analysed even when cryptate is present in the solution.
    Notes: Zusammenfassung Bei Verwendung von Bromkresolgrün als visueller Endpunktindicator kann man [2.2.1] und [2.2.2] Kryptandlösungen im Konzentrationsbereich 10−1–10−3 M mit relativen Standardabweichungen von 0,2–0,4% mit HCl titrieren. Wenn in einer Lösung sowohl Kryptand als auch Kryptat vorhanden ist, ist die Summe beider Substanzen auf die gleiche Weise bestimmbar. [2.2.1] und [2.2.2] können auch dadurch bestimmt werden, daß eine Calciumbzw. Barium-Standardlösung mit der Kryptandlösung unbekannter Konzentration titriert wird. Die Auswertung der dabei erhaltenen pH-Kurve ergibt den Titrationsendpunkt, wobei hierdurch im Konzentrationsbereich von 10−1–10−2 M Kryptandlösungen relative Standardabweichungen von etwa 0,5% erreicht werden. [2.2.1] Kryptandlösungen werden außerdem mit der Standard-Additionstechnik nach Gran bestimmt, wobei eine calciumselektive Elektrode als Indicatorelektrode dient. Dabei werden im Konzentrationsbereich von 10−2–10−4 M relative Standardabweichungen von etwa 3 % erhalten. Diese Methode kann auch überschüssigen Kryptand neben Kryptat bestimmen.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für anorganische Chemie 453 (1979), S. 23-27 
    ISSN: 0044-2313
    Keywords: Chemistry ; Inorganic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Chlorine Isotope Separation in a Heterogeneous Electrolyte System Dependence on the Concentration and the Counter Ion of a Fluoride SolutionIn a heterogeneous electrolyte system of a strongly basic anion exchanger and a concentrated fluoride solution the dependence of the chlorine isotope separation on the concentration and the counter ion of the fluoride solution is determined by chromatographic experiments. The results show the greatest separation effect of the chlorine isotopes so far achieved, using ion exchange reactions. 37Cl- is enriched in the solution phase, whereas 35Cl- is enriched in the ion exchanger. With increasing fluoride concentration the isotope separation effect decreases. The strong dependence of the isotope separation on the counter ion of the fluoride solution is shown using CsF and KF respectively.
    Notes: Im heterogenen Elektrolytsystem stark basischer Anionenaustauscher/konzentrierte Fluoridlösung wird die Abhängigkeit der Chlorisotopenseparation von Konzentration und Gegenion des Fremdelektrolyten in chromatographischen Versuchen bestimmt. Die Ergebnisse zeigen den bisher größten bekannten Elementartrenneffekt der Chlorisotope bei Ionenaustauschreaktionen, wobei sich das 37Cl- - gegenüber dem 35Cl--Ion in der Lösung des Systems anreichert. Mit steigender Fluoridkonzentration nimmt der Isotopentrenneffekt ab. Am Beispiel einer CsF - gegenüber einer KF - Lösung wird die starke Abhängigkeit der Isotopenseparation vom Gegenion des Fremdelektrolyten aufgezeigt.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Berichte der deutschen chemischen Gesellschaft 75 (1942), S. 1802-1814 
    ISSN: 0365-9631
    Keywords: Chemistry ; Inorganic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...