ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chemistry  (3,432)
  • 1975-1979  (1,712)
  • 1970-1974  (1,678)
  • 1940-1944  (42)
Collection
Publisher
Years
Year
  • 1
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0018-019X
    Keywords: Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The structure II of boromycin C45H74BNO15 (cf. [2]) has been established by combination of chemical evidence with X-ray analysis. The antibiotic is a D-valine ester of a Böeseken-complex of boric acid with a macrodiolide of a new type.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 18 (1974), S. 3543-3553 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: An analytical procedure for determining the antioxidant (i.e., Akroflex CD) content in neoprene rubber has been developed. The method is based on the infrared absorption analyses of chloroform extractables from the cured rubber at 1600 cm-1 and 1300 cm-1. Good agreement is found between these two independent sets of measurements. In an attempt to elucidate the antioxidant loss mechanism found with neoprene, thermal aging studies were carried out over the temperature range of 80°-200°C. Using the infrared analytical procedure, antioxidant loss rates at the different temperatures were established. The activation energy value (5.1 kcal/mole) for the loss rate as well as other aging data suggest that the antioxidant is lost by a diffusion mechanism.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 22 (1978), S. 2217-2228 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The destruction of various UV stabilizers in polypropylene films during irradiation has been examined both in the presence and absence of air and oxidation products. Although some stabilizers were destroyed in the absence of oxygen, all were more sensitive when irradiated in the presence of air. Several stabilizers were highly effective but were destroyed so rapidly that photoprotection of the polymer must have resulted from stabilizer products. Work with preoxidized polymer and with model hydroperoxides and peroxides indicated that most stabilizers were destroyed by the attack of oxygen-centered radicals, with peroxy radical attack appearing to dominate.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Gram-sized quantities of purified arginine, formylmethionine, glutamic acid, and phenylalanine-2 tRNAs have been prepared from pools of E. coli K-12 MO7 mixed tRNAs by reversed-phase chromatography after preliminary fractionation on DEAE-cellulose. Purified formylmethionine tRNA and partially purified arginine tRNA and glutamie acid tRNA were obtained from large-scale RPC-3 runs (4 × 36 in. column). The arginine tRNA was further purified by rechromatography on RPC-4 columns, and the gluatmic acid tRNA by rechromatography on an RPC-3 column. Two phenylalanine tRNAs were resolved on large-scale (2 × 96 in. column) RPC-3 runs; only the second phenylalanine tRNA reached a satisfactory degree of activity. About 0.88 g of arginine tRNA, 70% activity; 3.32 g of formylmethionine tRNA, 97% activity; 0.80 g of glutamic acid tRNA, 83% activity and O.92 g of phenylalanine-2 tRNA, 78% activity, were produced. The processing steps employed are reliable and reproducible and the procedure is amenable to routine production of these tRNAs.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 15 (1973), S. 1131-1145 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Several techniques for investigating the multiplicity and stability of open isothermal enzymatic reactors are discussed and some of the pitfalls in previous thinking pointed out. The example which is used to illustrate these methods exhibits several interesting features. Among these is the existence of a stable oscillatory state which surrounds a unique steady state which is asymptotically stable to certain finite disturbances.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 17 (1975), S. 1679-1693 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The suitability of hornblende as a support for immobilized β-fructofuranosidase (invertase) was studied, with regard to the physical stability of the support and the thermal and operational stability of the immobilized enzyme. Hornblende was more stable than Enzacryl-Alo or Enzacryl-TIO, and marginally more stable than porous glass. Invertase immobilized on hornblende was more stable during long-term operation than invertase immobilized on porous glass. An active preparation of immobilized invertase was obtained also on pyroxene particles.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 17 (1973), S. 269-282 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The development of gel permeation chromatography (GPC) has provided a convenient tool for the rapid determination of molecular weight distribution. The question has arisen as to the suitability of the method for specification purposes. The present work, suggested by the Naval Air Systems Command, represents an attempt to assess the precision of the method through a series of tests carried out by a number of laboratories using identical procedures on the same samples. Ten laboratories agreed to take part. Naval Ordnance Station, Indian Head, worked out standard conditions for operation of the chromatograph, for calibration of the columns, and for analysis of the GPC curves. Two samples of polystyrene were used by the various organizations for calibration of their instruments. Number-average molecular weight, heterogeneity index, and cumulative molecular weight distribution curves were determined on four samples of carboxyl-terminated polybutadiene (CTPB) and two samples of hydroxyl-terminated polybutadiene (HTPB), all unidentified except by letter code. All laboratories used identical directions for setting up CTPB and HTPB calibration curves which were based on curves determined from vapor-pressure osmometer molecular weights and GPC count numbers of fractionated material. Variation among the different laboratories was 0.15 in heterogeneity index, and a maximum of 1200 in molecular weight provided one aberrant set of values was eliminated. The six samples had heterogeneity indices from 1.15 to 1.54, while molecular weight varied from approximately 3000 to 6000. The average coefficient of variation of the molecular weight values was 6.2 ± 0.7%, which is quite acceptable. Variation in heterogeneity index was too great for specification purposes when considered among the different laboratories, but may be sufficiently good when measured by any one laboratory.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 16 (1972), S. 3353-3360 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Two independently derived distribution function methods validate both the calibration curve and the dispersion correction of the “effective linear calibration” method used in gel permeation chromatography (GPC). Experimental conditions are specified for making the method more useful by permitting linear extrapolation of the calibration line, \documentclass{article}\pagestyle{empty}\begin{document}$ V_R = C_1 + C_2 \log M, $\end{document} and for using a minimum number of standards. The independent methods quantitatively relate known differential of integral distribution functions for standard samples to their respective chromatograms. As such, they are useful calibration methods also, but are limited in scope and range.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: A D2-m-dodecacarboranesiloxane containing alternating block copolymer \documentclass{article}\pagestyle{empty}\begin{document}$\rlap{--}[{\rm A}\hbox{---}{\rm B}\rlap{--}]_n$\end{document} was prepared by the reaction of a ureidosilane-terminated polysulfone hard block with a carboranesilanol-terminated carboranesiloxane oligomer. The resulting block copolymer exhibited thermoplastic elastomeric behavior. This unique polymer had excellent thermal stability up to 400°C.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...