    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Preparation of deactivated capillaries for routine analysis ; Easy deactivation and pretreatment steps described in detail ; Comparison of different modes given ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new surface pretreatment for the preparation of wall-coated open tubular (WCOT) glass capillary columns has been evaluated. This technique involves the application of a non-extractable layer of Superox™-4, a 4,000,000 MW polyethylene glycol, to the glass surface as a pretreatment and deactivation agent. Unlike other polyethylene glycols, Superox-4 is stable at high temperatures (〉 300°C) in the absence of oxygen, coats smoothly onto a bare glass surface and resists droplet formation. WCOT columns (SE-54, Carbowax 20M, and SP-2250) prepared using this technique are compared to columns prepared using a modified Grob [2,3] BaCO3 procedure. The Superox-4 pretreated columns were equal or superior in quality to the BaCO3 pretreated columns, based on the appearance of an activity standard and the effective theoretical plates (Neff) per meter. Chromatograms showing practical application of the WCOT columns prepared using both methods is given.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 444-445 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Open-tubular columns ; Reduced diameter ; High pressure ; Coating reservoir ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 333-336 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Liquid crystal ; N,Ń, Bis (p-phenylbenzylidene)-α, α′-bi-p-toluidine (BPhBT) ; Steroids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A gas-chromatographic separation of underivatized steroids is described, in which the liquid crystal N,Ń-bis(p-phenylbenzylidene)α,α′-bi-p-toluidine (BPhBT) was used isothermally at 265°C for the stationary phase. The nematic range of this crystal is 247 to 403°C. Use of the BPhBT crystal allowed operations in a temperature range where steroids are volatile and unlikely to display broad elution peaks and long retention times.With columns precoated with 2.5 weight percent of BPhBT, steroids containing minor structural differences in the ring system were readily differentiated. For example, 5-androsten-17α-ethinyl-3β, 17β-diol was found to elute more rapidly than its 3-keto analog, ethisterone. Ethisterone was distinguished readily also from its 19-nor analog, norethisterone. Additionally, differences in side-chain functionality and resultant molecular dimensions facilitated the separation of steroids of identical ring structure, as in the comparison of cholesterol with methyl 3β-hydroxy-5-cholenate and 25-hydroxycholesterol.An enhancement of separation according to the molecular length-to-breadth ratio was observed; in general, the larger this length-to-breadth ratio, the greater the retention period on the column.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...