ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (55)
  • NDE  (21)
  • Gas chromatography  (17)
  • healthy volunteers  (17)
  • Springer  (55)
  • 1980-1984  (55)
Collection
  • Articles  (55)
Keywords
Publisher
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 21 (1982), S. 433-441 
    ISSN: 1432-1041
    Keywords: antipyrine ; antipyrine metabolites ; drug metabolism ; route of administration ; healthy volunteers ; urinary excretion ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of antipyrine in plasma and saliva, and urinary excretion of its major metabolites, were studied following i.v. and oral administration of antipyrine 500 mg to 6 healthy volunteers. Data from both plasma and saliva showed that the oral bioavailability of antipyrine given as an aqueous solution was complete. The saliva/plasma concentration ratio was constant with time from about 3 h onwards, with a mean value of 0.87 after oral and 0.91 after i.v. administration. It is concluded that the pharmacokinetic parameters of antipyrine can be satisfactorily established on the basis of salivary data, although the volume of distribution and clearance values are then slightly too high. After i.v. administration, 3.8±1.9% of the dose was excreted in urine as unchanged antipyrine in 48h, 24.9±6.3% as 4-hydroxyantipyrine, 16.5±3.2% as norantipyrine, 13.0±2.2% as 3-hydroxymethyl-antipyrine and 5.8±1.0% as 3-carboxy-antipyrine. No significant differences were observed following oral administration. The half-lives calculated from the linear part of the urinary excretion rate curves of the metabolites were about the same for oral and i.v. administration, and were of the same order of magnitude as the elimination half-life of parent drug in plasma and saliva. It is important for determination of the ultimate metabolite ratio that urine is collected for at least 36h, because there is a delay in the excretion of 3-hydroxymethyl-antipyrine in urine.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 27 (1984), S. 447-452 
    ISSN: 1432-1041
    Keywords: alaproclate ; antipyrine clearance ; serotonin reuptake inhibitor ; healthy volunteers ; antipyrine metabolism ; metabolite clearance ; alaproclate kinetics ; inhibition of drug metabolism
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Alaproclate, a selective serotonin reuptake inhibitor, presently undergoing clinical trial for the treatment of major depressive disorders, has been shown to inhibit hexobarbital metabolism in mice. In the present study the influence of oral alaproclate on the total plasma clearance of antipyrine and on the formation of its metabolites was investigated in 10 healthy volunteers. The peak level of alaproclate was reached after about 1.5 h, and after a distribution phase, its plasma elimination half-life was between 3.0 and 3.5 h. Antipyrine tests were performed before treatment, during the first four doses and after the seventh dose of alaproclate 200 mg/day. During treatment, total plasma antipyrine clearance and the clearance for production of all antipyrine metabolites were reduced by 30%, indicating non-selective inhibition of oxidative drug-metabolizing enzyme activity in man by alaproclate. After the last dose of alaproclate, antipyrine plasma clearance and the clearance to its metabolites returned to control values. In order to allow more detailed evaluation of the results, the time course of the clearances for production of metabolites was investigated. This revealed that the extent of inhibition of metabolite formation by alaproclate was dependent on the plasma alaproclate level, indicating a rapidly reversible inhibition.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 195-202 
    ISSN: 1573-4862
    Keywords: ac potential difference ; fatigue crack measurement ; slots ; artificial flaws ; parasitic voltages ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract The development of a successful and accurate instrument for measuring surface-breaking cracks in metals using the ac field technique has raised several interesting theoretical problems. Measurements with the instrument, known as the Crack Microgauge, do not rely on any prior calibration against an artificial flaw such as a saw-cut in a test block, but some users accustomed to such a calibration from other devices have nevertheless wished to use the instrument in that fashion and have in some instances reported erroneous results. In this paper, we develop a simple theory to explain and quantify this phenomenon. We calculate the parasitic voltages induced in the instrument probe due to the finite opening possessed by an artificial flaw, and we use these results to reinterpret the instrument readings. Controlled experimental measurements on artificial flaws of rectangular cross-section made in aluminum and in steel are found to be in good agreement with the theory. It is shown, however, that application of the theory requires additional information about the internal phase shift associated with the instrument. To enhance the accuracy of the theory, the effect of the corners of the artificial flaws was also considered, although it was not very influential in this work.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 3 (1982), S. 65-76 
    ISSN: 1573-4862
    Keywords: crack measurement ; ac field technique ; arbitrary skin depth ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract A general solution is given to describe the ac field around surface-breaking cracks for arbitrary values of the ratio of skin depth δ to crack depthd. This solution allows accurate interpretation of crack depth from voltage readings taken by a Crack Microgauge instrument in cases where δ andd are comparable. It is shown to agree with asymptotic formulae obtained for the cases where δ/d is very small and very large. Provided that the probe length Δ is large compared with δ, the calculations show that a very good approximation to the crack depth may be obtained, irrespective of the ratio δ/d, by using the thin-skin asymptotic formula $$d = \frac{1}{2}\Delta (V_2 - V_1 )/V_1 $$ whereV 1 andV 2 are probe voltages registered at positions just off and across the crack, respectively. The problem is solved for a crack of infinite aspect ratio which has no opening, but it can be applied with confidence at the centerline of cracks of fairly large aspect ratio.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 4 (1984), S. 3-12 
    ISSN: 1573-4862
    Keywords: Ultrasonic ; stress measurements ; interfacial stress ; NiTi ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract In seeking to develop an NDE technique for verifying the serviceability of NiTi couplers for plumbing unions, it was found that the reflection coefficient for a normally incident ultrasonic wave correlated with the stress level at the NiTi-tubing interface. Current theory pertaining to interface reflection is not complete but, even at present status, there is semiquantitative accord between theoretical predictions and normalized data for reflection coefficient versus stress level. These results are at fixed frequency and with comparable surface roughness. Variation of either frequency or surface roughness further affects the reflection coefficient. Current studies are being pursued to define this effect.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1573-4862
    Keywords: stress fields ; microstructure ; J integral ; stress intensity factor ; harness acoustic velocity ; acoustic elasticity ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract A very precise system for measuring two-dimensional velocity fields in solid samples has been used for nondestructive measurements of both externally applied and residual inhomogeneous stresses in solids,J integrals, stress intensity factors of cracks, and hardness of quenched steel. The longitudinal velocity measurement is based on precise determination of the propagation transit time through the stressed solid specimen using a small diameter, water-coupled acoutic transducer, which is scanned mechanically over the sample. Changes in velocity are then related to changes of stress in the sample by the theory of acoustoelasticity. Similar measurements show a high degree of correlation between longitudinal velocity changes and changes in microstructure in steel samples. Applications to problems of solid mechanics and material science illustrate the utility of this nondestructive measuring technique.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 65-74 
    ISSN: 1573-4862
    Keywords: NDE ; cast iron ; vibration analysis ; modulus ; strength
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract An outline is given of the existing nondestructive vibration tests for cast irons and their drawbacks in terms of the dimensional accuracy of the components. A proposal is made for a new test based on the change of resonant frequency with vibration amplitude exhibited by cast irons. This proposal is evaluated using material data obtained from dynamic tests of a wide range of cast iron specimens. A test rig is described suitable for testing cylindrical cast bars, and typical results are presented in relation to material strength. There is also a brief description of preliminary testing on cast products.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1612-1112
    Keywords: Teflon capillary columns ; Chemically modified teflon ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The preparation of teflon capillary columns employing direct coating of the stationary phase to the chemically modified teflon surface and the role of the chemically modified teflon in the separation mechanism are described. Two types of contributions from the modified teflon have been observed: nonspecific adsorption of the carbon surface and specific interactions of polar groups in the carbon skeleton. The use of polar liquid phases can eliminate adsorption due to the presence of polar groups in the modified teflon.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Modified thermal energy analyzer ; Selective detection of nitrogen compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A modification to the TEATM Analyzer is described, which allows it to be used as a highly selective GC detector for nitrogen compounds as well as for N-nitrosamines and nitro compounds. The modified Analyzer is as sensitive as the AFID, but has a much higher selectivity towards nitrogen compounds than the AFID. Its response appears to be molar, with an output that is dependent only on the number of nitrogen atoms present. The performance of the modified Analyzer for the analysis of ammonia, amines,N-nitrosamines, nitriles and organonitro compounds is reported and discussed, as is its application to the detection of these compounds in bacon and beer samples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 17 (1980), S. 349-354 
    ISSN: 1432-1041
    Keywords: propranolol ; radioreceptor assay ; beta-adrenoceptor antagonists ; lung membranes ; plasma level ; healthy volunteers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary A radioreceptor assay (RRA) recently developed in this laboratory for beta-adrenoceptor antagonists in plasma was evaluated in normal volunteers and compared with a radioimmunoassay (RIA) for propranolol. The RRA depends upon the ability of beta-adrenoceptor antagonists to compete with a radiolabelled ligand for beta-adrenoceptor binding sites on lung membranes. Unlike other assays, it measures biologically active drugs including active metabolites of the parent compound. In volunteers given a single oral dose of (±)-propranolol, considerable differences between the two assay methods were demonstrated. In other experiments this difference was shown to relate to the RIA's sensitivity to the inactive (+)-isomer of propranolol and possibly to inactive metabolites. The facility of the RRA in measuring plasma levels of several other non-selective beta-adrenoceptor antagonists was also demonstrated. By employing (−)-propranolol as the standard in the RRA, all of these drugs can be directly compared with a single and relatively simple assay technique.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...