ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (6)
  • Liquid chromatography  (4)
  • metoprolol  (2)
  • Atomic, Molecular and Optical Physics
  • Springer  (6)
  • 1980-1984  (6)
  • Chemistry and Pharmacology  (6)
Collection
  • Articles  (6)
Publisher
Years
  • 1980-1984  (6)
Year
Topic
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 283-288 
    ISSN: 1432-1041
    Keywords: metoprolol ; atenolol ; beta1-adrenergic blockade ; exercise ; anaerobic metabolism ; circulatory effects ; ventilatory effects ; plasma levels
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Maximal exercise performance by eight healthy male subjects was tested after one week of medication with slow-release metoprolol 200 mg/d (metoprolol-SR), atenolol 200 mg/d or placebo, in a double blind crossover trial. The maximal working capacity was significantly decreased after atenolol and metoprolol-SR. Plasma glucose and FFA concentrations during the exercise test did not change: either after placebo therapy or after beta-blockade. The anaerobic threshold did not change after beta-blockade, but the changes in lactate due to the exercise were less after beta-blockade. Neither beta-blocker affected the exercise-induced alteration in airway resistance. Both drugs caused a small but significant ventilatory depression at rest and at 75% of maximal exercise. It is concluded that the limiting factor in maximal exercise performance after β1-adrenergic blockade does not lie in oxygen transport to the working muscles via ventilation and the circulation, but is most probably due to anaerobic metabolism.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 27 (1984), S. 141-145 
    ISSN: 1432-1041
    Keywords: asthma ; beta1-selective blockers ; bisoprolol ; metoprolol ; terbutaline inhalation ; ventilatory effects ; plasma levels
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary In a double blind, placebo-controlled study the ventilatory effects of the beta1-selective receptor blockers bisoprolol (EMD 33512) and metoprolol and their interactions with the beta2-adrenoceptor agonist terbutaline were investigated in 8 asthmatic patients. Both beta-blockers, in all the doses given, caused a significant decrease in peak expiratory flow rate (PEFR). Vital capacity (VC) and forced expiratory volume in one second (FEV1) were significantly decreased only after 10 mg bisoprolol. Terbutaline inhalation caused the same significant improvements in FEV1 and PEFR during placebo as during bisoprolol 10 mg, bisoprolol 20 mg and metoprolol 100 mg. Both beta-blockers caused equal changes in heart rate (HR) at rest. Systolic and diastolic blood pressure (BP) decreased significantly after bisoprolol 20 mg and metoprolol 100 mg, but not after bisoprolol 10 mg. Inhalation of terbutaline up to a dose of 3.5 mg had no influence on HR and BP. The results point to good beta1-selectivity of bisoprolol 10 mg and 20 mg and metoprolol 100 mg in asthmatic patients. No correlation was found between the plasma levels of the beta-blockers and the changes in the ventilatory indices, HR or BP.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Liquid chromatography ; Chlorophenols in water ; Preconcentration ; Post-column photochemical dechlorination ; Electrochemical, UV and fluorescence detection ; Column switching
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A specific HPLC method has been developed for the trace analysis of lower chlorinated aromatic compounds. The method consists of an on-line preconcentration and a post-column reaction step. On-line preconcentration of mono- and dichlorophenols from aqueous samples has been performed using PRP1, a divinylbenzene-styrene copolymeric sorbent as packing material for both pre-and analytical column. Enrichment factors of over 300 were obtained compared to regular (100 μl) loop injections, even for the highly polar monochlorophenols. After reversed-phase separation, post-column photochemical dechlorination is carried out directly in the eluent stream, using a photochemical reactor. Upon dechlorination, fluorescent products are formed, which can be detected selectively. The resulting fluorescence signal shows a linear response to the quantity of solute present over 2 to 3 orders of magnitude (correlation coefficients: 0.990–0.98). For the mono- and dichlorophenols, the detection limit of the photoconversion method is in the lower nanogram range. The method is especially suitable for the analysis of complex matrices such as effluent water samples or biological fluids containing traces of the polar chloroaromatic compounds together with large amounts of other constituents, which interfere when using more general methods of detection like UV absorption. The potential of this technique for automation has been demonstrated by using a microprocessor-controlled column switching unit.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1612-1112
    Keywords: Liquid chromatography ; Photochemical reaction detection ; Chemical post-column reduction ; Fluorimetric detection ; Air segmented flow systems ; Non-aqueous reversed-phase chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new photochemical reaction method for the on-line fluorimetric detection of natural vitamin K homologs was developed. In addition to its high sensitivity, the method features an interesting selectivity for the determination of these compounds in a complex matrix such as human serum. The formation of different photolysis products as a function of reaction conditions, and the optimalisation of a segmented flow reaction system will be discussed. The results indicate that the method is 4 times more sensitive than UV detection, and at least as selective as fluorescence detection after post-column chemical reduction.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1612-1112
    Keywords: Liquid chromatography ; Nucleobases ; Nucleosides ; Silica gel
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The retention behaviour of nucleobases and nucleosides on unmodified silica with dichloromethane-methanol-water mixtures has been systematically investigated. The degree and order of retention can be varied over a wide range by changing the pH, the type and concentration of the acidic additives and by the methanol and water content of the mobile phase. The retention process cannot be considered as simple adsorption but rather as a very complex mixed distribution process of adsorption and absorption including the involvement of ion-pair formation. Further data on the effect of the type of silica (source of supply) on retention behaviour, column efficiency and column reproducibility are reported. The practical application of unmodified silica for the separation of nucleobases and nucleosides is demonstrated by the analysis of a hydrolysate of calf thymus DNA.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 237-241 
    ISSN: 1612-1112
    Keywords: Liquid chromatography ; Electron capture detection ; Improved interface
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An improved interface for the coupling of a liquid chromatograph (LC) and an electron-capture detector (ECD) allows the use of the LC-ECD combination for the determination of various types of chlorinated aromatic compounds. The addition of up to 6% of dioxan to the hexane used as mobile phase can be tolerated without serious deterioration of detector performance. Derivatization of polar compounds such as anilines, phenylurea herbicides, chlorophenols and hydroxylated polychlorobiphenyls with fluorine-and non-fluorine-containing acid anhydrides is a useful tool to extend the application range of LC-ECD. As an example, the analysis of a spiked soil sample is discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...