    Electronic Resource
    Electronic Resource
    Springer
    Entomologia experimentalis et applicata 34 (1983), S. 20-26 
    ISSN: 1570-7458
    Keywords: Dioryctria abietella ; Cone pyralid ; Lepidoptera ; Pyralidae ; Sex pheromone, (Z,E)-9,11-tetradecadienyl acetate ; Single sensillum recordings ; Electroantennography ; Gas chromatography ; Mass spectrometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Description / Table of Contents: Résumé L'analyse en chromatographie gazeuse associée à une détection électroantennographique a montré que l'acétate (Z,E)-9,11-tétradécadiényle (Z,E)-9,11–14:Ac est l'un des composants de la phéromone de Dioryctria abietella Schiff (Lepid.: Pyralidae). Couplage chromatographie en phase gazeuse spectrometrie de masse a montré la présence d'acétate tétradécadiényle avec un spectre de masse et un indice de rétention identiques au Z,E-9,11–14:Ac Un récepteur cellulaire sensible à la fois au Z,E-9,11–14:Ac et à un extrait de la femelle a été identifié sous l'antenne du mâle. Les analyses des antennogrammes et de la cellule isolée ont étayé la caractérisation du composant de la phéromone comme étant Z,E-9,11–14:Ac. Un récepteur cellulaire additionnel sensible à l'acétate (Z.)-9-tétradécadiényle et à l'acétate (Z.E.)-9,12-tétradécadiényle a été trouvé sur l'antenne du mâle, mais il n'était pas activé par l'extrait de la femelle. Sur le terrain Z,E-9,11–14:Ac, présenté seul, attirait des nombres importants de mâles de D. abietella. L'addition de l'acétate (Z)-9-tétradécényle a inhibé l'attraction des mâles par les pièges.
    Notes: Summary Gas chromatographic analyses coupled with electro-antennographic detection indicated that (Z,E)-9,11-tetradecadienyl acetate (Z,E-9, 11–14:Ac) is a pheromone component of the cone pyralid Dioryctria abietella. Gas chromatographic-mass spectrometric analyses confirmed the presence of a tetradecadienyl acetate with mass spectrum and retention index identical to Z,E-9,11–14:Ac. A receptor cell sensitive to both Z,E-9,11–14:Ac and the female extract was identified on the male antenna. An additional receptor cell sensitive to (Z)-9-tetradecenyl acetate and (Z,E)-9,12-tetradecadienyl acetate was found on the male antenna but was not activated by the female extract. In the field Z,E-9,11–14:Ac presented alone attracted significant numbers of male D. abietella. Addition of (Z)-9-tetradecenyl acetate inhibited the attraction of males to traps.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 13 (1980), S. 203-206 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Carrier gas purity ; Sample stability
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The amount of oxygen which may be present in the gas volume corresponding to a peak is investigated and compared to the sample amounts. It is shown that even with high purity carrier gases one may have a significant excess of oxygen present at low sample amounts. Attention is drawn to the possibility of impurity build-up by diffusion e.g. through the septum.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 243-248 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Carrier gas ; Viscosity ; Influence of temperature
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The vicosity-temperature relationship of the three gases (helium, nitrogen and hydrogen) most frequenly used as the carrier gas in gas chromatography is studied. Based on available data, equaitions are derived to describe this relationship. Using these equations viscosity data are tabulated for the chromatographically important temperature range.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Configuration ; Resolution ; Alcohols
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The study of the resolution of sixteen secondary aliphatic alcohols by gas chromatography on (+)-dodecyl (2R, 3R)-tartrate, trapping the ascending part of the peak from a conventional filled column, has allowed the determination in a single operation of the sign and order of emergence of enantiomers. A correlation between the configuration of these secondary alcohols and their order of emergence has been established.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 477-488 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open tubular (capillary) columns ; Sample capacity ; Column comparison ; Film thickness ; Column diameter
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Wall-coated, open-tubular (capillary) columns prepared from different diameter tubing, with different liquid phase film thickness, are compared with each other and with packed and support-coated open-tubular columns. The comparison is based on the variation of the phase ratio and the capacity factor, and includes column efficiency (HETP, theoretical plate number), resolution, retention time, and sample capacity. Problems associated with the evaluation of the sample capacity are outlined. The influence of temperature on column performance is discussed in detail. Finally, the possibilities of short, wide-bore open-tubular columns prepared with a thick liquid-phase film are demonstrated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 13 (1980), S. 686-692 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Micropacked columns in GC ; Microparticles
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Porous silica microparticles designed for modern liquid chromatography have proven effective in gas chromatography. Columns of 35–50 cm gave plate heights as low as 3.3 particle diameters and speeds of 2400 theoretical plates per second or 500 effective theoretical plates per second. Inlet pressures up to 70 atmospheres were required using hydrogen as carrier gas. The particles as received were too retentive for fast chromatography and gave asymmetric peaks. A coating of fluorosilicone oil overcame both problems. Other coatings were less effective. Bonded phases proved less satisfactory on both counts and also gave substantially less efficient columns and greater flow resistance. Column efficiency and flow resistance were sharply dependent on physical properties of the particles. The most efficient packing was clearly spherical particles of 5–10 μm diameter with narrow size distribution, pore diamters about 50 nm, BET surface areas of 25–50 m2/g and surfaces modified with trifluoropropyl silicone. A six-component hydrocarbon sample was separated in 33 s with a resolution of 4 for the most difficult pair and in 2.6 s with a minimal resolution. Performance was limited by end effects and by available pressure so that much better performance can be expected from longer columns and higher pressures.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 13 (1980), S. 73-84 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Gas hold-up time ; Dead time
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The two approaches used for the calculation of the gas hold-up time and thus, the adjusted retention time are outlined, first for the restricted case when the carbon numbers of the three homologues used for the calculation are evenly spaced (c3−c2=c2−c1) and then, for the general case when (c3−c2) differs from (c2−c1). The basic difference in the philosophy of the two approaches is shown.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 576-578 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Tortuosity factor
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The relationship between the obstructive factor γ and velocity was restudied. The dependence of the obstructive factor on velocity was verified. The effects of diffusion coefficient and particle-to-column diameter ratio on the obstructive factor-velocity relationship were investigated. The results are consistent with Hawkes' hypothesis that values of γ at low velocities are averages over tightly packed and loosely packed domains while at high velocities they are weighted in favour of the loosely packed domains where there is more flow.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 625-630 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open-tubular (capillary) columns ; Comparison of liquid phases ; Influence of temperature ; Retention index data
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The influence of temperature and liquid phase film thickness of open-tubular (capillary) columns on the retention index values of hydrocarbons on methylsilicone liquid phases is discussed. Data obtained on methylsilicones and squalane are compared. Retention index values of 43 hydrocarbons between 40 and 70 °C on OV-101 liquid phase are listed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 13 (1980), S. 207-208 
    ISSN: 1612-1112
    Keywords: Trace determination ; Hydrogen chloride ; Ethylene oxide ; Gas chromatography ; Chlorinated solvents
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method is described for the determination of small quantities of hydrochloric acid in two chlorinated organic solvents (CHCl3 and CCl4). An excess of gaseous ethylene oxide is added to a liquid sample; the 2-chloroethanol formed is then analyzed by gas chromatography. The procedure is simpler and more sensitive in comparison with other conventional methods. It can be modified for other organic solvents.