ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • healthy volunteers  (17)
  • Biomagnetism (including magnetocardiography)  (16)
  • Bone  (16)
  • Springer  (49)
  • American Chemical Society
  • Nature Publishing Group
  • 1980-1984  (49)
Collection
Keywords
Publisher
  • Springer  (49)
  • American Chemical Society
  • Nature Publishing Group
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 2 (1983), S. 203-213 
    ISSN: 0392-6737
    Keywords: Biomagnetism (including magnetocardiography) ; Superconducting devices ; superconducting magnets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Description / Table of Contents: Riassunto Si è studiato lo spettro del rumore di un gradiometro superconduttore a derivata secon da in un agglomerato urbano. I dati sono stati ottenuti dal gradiometro con tre accelerometri ortogonali e un magnetometro a flussometro elettronico triassiale attaccato al dewar. Questi dati sono stati analizzati usando tecniche di elaborazione dei segnali, soprattutto un cancellatore adattativo di rumori, per ridurre i rumori nei dati del gradiometro. I risultati mostrano qui che il rumore dell’esterno e/o il rumore del movimento del dewar possono essere ridotti di 40 dB in potenza di rumore. Si è anche mostrato che, nel caso di basso rapporto segnale-rumore (S/N∼1), può essere estratta un’onda sunusoidale di 10 Hz. Questa tecnica non solo promette riduzione dei rumori, ma ha anche lo scopo d’identificare i segnali di rumore che potrebbero essere veramente considerati parte del responso evocato. L’analisi dei dati che contengono i responsi evocati è ora in corso.
    Notes: Summary The noise spectrum of a superconducting second-derivative gradiometer has been investigated in an urban environment. Data have been acquired from the gradiometer with three orthogonal accelerometers and a triaxial fluxgate magnetometer attached to the dewar. These data have been analyzed by using signal processing techniques, primarily an adaptive noise canceller, to reduce noise in the gradiometer data. Results shown here indicate that the environmental noise and/or the dewar motion noise can be reduced as much as 40 dB in noise power. It is also shown, in the case of poor signal-to-noise ratio (S/N∼1), that a 10 Hz sine wave can be extracted. This technique not only shows promise for noise reduction, but also aids in the identification of noise signals which might be misconstrued as part of the evoked response. Analysis of data containing evoked response is now underway.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 2 (1983), S. 184-194 
    ISSN: 0392-6737
    Keywords: Biomagnetism (including magnetocardiography) ; Superconducting devices ; superconducting magnets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Description / Table of Contents: Riassunto Si è costruito espressamente un sistema SQUID in un ospedale di Parigi, che permette indagini neuromagnetiche attinenti con applicazioni cliniche. Un gradiometro simmetrico di second’ordine lavora entro uno schermo per corrente parassite. Ciò è designato ad ottimizzare il costo e l’efficienza del sistema. Le sue prestazioni sono state sperimentate con dati da pazienti e da soggetti normali.
    Notes: Summary A SQUID system was specially built in a Parisian hospital, allowing neuromagnetic investigations dealing with clinical applications. A second-order symmetrical gradiometer works inside an eddy current shield. This was designed for optimizing the cost and the efficiency of the system. Its performances were tested with data from patients and normal subjects.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 2 (1983), S. 505-511 
    ISSN: 0392-6737
    Keywords: Biomagnetism (including magnetocardiography) ; Superconducting devices ; superconducting magnets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Description / Table of Contents: Riassunto Si è studiato il campo magnetico prodotto dal cervello prendendo in considerazione una varietà di eventi rari. Si riporta il carattere temporale della risposta a un raro stimolo uditivo. Il campo magnetico appare offrire un’utile nuova sonda dell’attività endogena nel cervello umano.
    Notes: Summary We have studied the magnetic field produced by the brain when attending to a variety of rare events. The temporal character of the response to a rare auditory stimulus is reported. The magnetic field appears to offer a useful new probe of endogeneous activity in the human brain.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 2 (1983), S. 255-265 
    ISSN: 0392-6737
    Keywords: Biomagnetism (including magnetocardiography) ; Superconducting devices ; superconducting magnets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Description / Table of Contents: Riassunto È stata sfruttata la risoluzione spaziale del sensore magnetico per fornire stime numeriche del contributo atriale ai campi magnetici registrati esattamente prima della depolarizzazione ventricolare. Si trova che il contributo è piccolo, e questo rafforza l’interpretazione originale secondo la quale questi campi derivano principalmente dal sistema di conduzione del cuore.
    Notes: Summary We have exploited the spatial resolution of the magnetic sensor to provide numerical estimates of the atrial contribution to magnetic fields recorded just prior to ventricular depolarization. The contribution is found to be small, strenghening our original interpretation that such fields originate mostly in the conduction system of the heart.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 33 (1981), S. 369-374 
    ISSN: 1432-0827
    Keywords: Histomorphometry ; Bone ; Reproducibility
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary To study bone histomorphometry reproducibility in normal subjects, we performed during orthopedic surgery bone biopsies in 16 post-menopausal women. Each woman had four bone biopsies, two at the usual site in the iliac crest, one on the left and one on the right side, and two other biopsies just behind the usual site, one at each side. We performed measurements of trabecular bone volume, relative osteoid volume, osteoid surfaces, osteoclastic resorption surfaces and calcification front. The average values of the 16 patients were compared, on the one hand, two by two, by a student test, and on the other hand, by a variance analysis. By these two methods the results showed no significant difference between the average values of the 16 patients at each location for any of the histomorphometric parameters studied. However, there was a location variation which was estimated by the intra-individual variation for a given patient. On the other hand, we calculated from the variance analysis the location variance for a group of 10 to 100 patients. In any case all the parameters had a location variation which was high for osteoclastic resorption surfaces and relative osteoid volume when expressed in % of the absolute value of these parameters. The variation of the trabecular bone volume was 0–46. 15% (95% confident limit interval) in a single patient and the hypothetical value of the location variation was 41.6% for a group of 10 patients and 13.0% for a group of 100 patients.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 27 (1984), S. 447-452 
    ISSN: 1432-1041
    Keywords: alaproclate ; antipyrine clearance ; serotonin reuptake inhibitor ; healthy volunteers ; antipyrine metabolism ; metabolite clearance ; alaproclate kinetics ; inhibition of drug metabolism
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Alaproclate, a selective serotonin reuptake inhibitor, presently undergoing clinical trial for the treatment of major depressive disorders, has been shown to inhibit hexobarbital metabolism in mice. In the present study the influence of oral alaproclate on the total plasma clearance of antipyrine and on the formation of its metabolites was investigated in 10 healthy volunteers. The peak level of alaproclate was reached after about 1.5 h, and after a distribution phase, its plasma elimination half-life was between 3.0 and 3.5 h. Antipyrine tests were performed before treatment, during the first four doses and after the seventh dose of alaproclate 200 mg/day. During treatment, total plasma antipyrine clearance and the clearance for production of all antipyrine metabolites were reduced by 30%, indicating non-selective inhibition of oxidative drug-metabolizing enzyme activity in man by alaproclate. After the last dose of alaproclate, antipyrine plasma clearance and the clearance to its metabolites returned to control values. In order to allow more detailed evaluation of the results, the time course of the clearances for production of metabolites was investigated. This revealed that the extent of inhibition of metabolite formation by alaproclate was dependent on the plasma alaproclate level, indicating a rapidly reversible inhibition.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 21 (1982), S. 433-441 
    ISSN: 1432-1041
    Keywords: antipyrine ; antipyrine metabolites ; drug metabolism ; route of administration ; healthy volunteers ; urinary excretion ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of antipyrine in plasma and saliva, and urinary excretion of its major metabolites, were studied following i.v. and oral administration of antipyrine 500 mg to 6 healthy volunteers. Data from both plasma and saliva showed that the oral bioavailability of antipyrine given as an aqueous solution was complete. The saliva/plasma concentration ratio was constant with time from about 3 h onwards, with a mean value of 0.87 after oral and 0.91 after i.v. administration. It is concluded that the pharmacokinetic parameters of antipyrine can be satisfactorily established on the basis of salivary data, although the volume of distribution and clearance values are then slightly too high. After i.v. administration, 3.8±1.9% of the dose was excreted in urine as unchanged antipyrine in 48h, 24.9±6.3% as 4-hydroxyantipyrine, 16.5±3.2% as norantipyrine, 13.0±2.2% as 3-hydroxymethyl-antipyrine and 5.8±1.0% as 3-carboxy-antipyrine. No significant differences were observed following oral administration. The half-lives calculated from the linear part of the urinary excretion rate curves of the metabolites were about the same for oral and i.v. administration, and were of the same order of magnitude as the elimination half-life of parent drug in plasma and saliva. It is important for determination of the ultimate metabolite ratio that urine is collected for at least 36h, because there is a delay in the excretion of 3-hydroxymethyl-antipyrine in urine.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 2 (1983), S. 123-141 
    ISSN: 0392-6737
    Keywords: Biomagnetism (including magnetocardiography) ; Superconducting devices ; superconducting magnets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Description / Table of Contents: Riassunto Si riesamina la strumentalizzazione adatta all’acquisizione di segnali biomagnetici. Si studiano separatamente i componenti di base del magnetometro, cioè gli SQUID, i trasformatori di flusso e i dewar. Si discutono i possibili miglioramenti alla strumentazione attuale e alle apparecchiature complete comprendenti scudi ferromagnetici o di correnti a vortice e si valuta la loro efficenza.
    Notes: Summary The instrumentation suitable for the acquisition of biomagnetic signals is reviewed. The basic magnetometer components,i.e. SQUIDs, flux transformers and dewars, are studied separately. Possible improvements to the present instrumentation as well as complete set-ups including ferromagnetic or eddy current shields are discussed and their efficiency evaluated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 2 (1983), S. 166-174 
    ISSN: 0392-6737
    Keywords: Biomagnetism (including magnetocardiography) ; Superconducting devices ; superconducting magnets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Description / Table of Contents: Riassunto Si è costruito un magnetometro SQUID differenziale a 3 canali per la misurazione simultanea delle 3 componenti ortogonali del campo magnetico nella stessa posizione. Si descrive la struttura dell’apparecchio e si mostrano i dati MCG misurati. Si discutono gli effetti d’interferenza tra i canali.
    Notes: Summary We have constructed a three-channel differential SQUID magnetometer for the simultaneous measurement of the three orthogonal components of the magnetic field in the same location. The structure of the device is described and MCG data measured are shown. Interference effects between the channels are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0392-6737
    Keywords: Biomagnetism (including magnetocardiography) ; Superconducting devices ; superconducting magnets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Description / Table of Contents: Riassunto Si è sviluppato un metodo magnetico per misurazioni dirette non invasive del ferro di immagazzinamento epatico umano con uno suscettometro SQUID. Le determinazioni magneticain vivo e chimicain vitro del ferro epatico non eme sono strettamente correlate. Le misurazioni magnetiche dei depositi di ferro sono utili, dal punto di vista clinico, nella diagnosi dei disordini nel metabolismo del ferro.
    Notes: Summary A magnetic method for direct noninvasive measurements of human hepatic storage iron with a SQUID susceptometer has been developed.In vivo magnetic andin vitro chemical determinations of liver nonheme iron are closely correlated. Magnetic measurements of iron stores are clinically useful in the diagnosis of disorders of iron metabolism.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...