ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (162)
  • Chemistry  (162)
  • Life and Medical Sciences
  • 1980-1984  (101)
  • 1970-1974  (61)
  • 1940-1944
  • Technology  (162)
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 4 (1970), S. 145-187 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The influences of the conditioning treatments, surface topography, and crystal structure of carbonaceous surfaces on their ability to sorb heparin and their in vivo compatibility with blood were investigated. The results of the sorption studies indicated that the adsorption of heparin on the surfaces of turbostratic and graphitic materials is not crystallographically selective and that the amount adsorbed on relatively smooth surfaces is near the amount expected for monolayer formation. Although the adsorption of heparin on relatively smooth carbon surfaces is not influenced by the presence of benzalkonium chloride, the sorption of heparin in porous carbons can be greatly increased by a pretreatment with benzalkonium chloride. This increase was found to be due to the formation and entrapment of the insoluble heparin-benzalkonium complex in the accessible porosity. Since the heparin sorptions in Dag-154 coatings were found to be enhanced by a pretreatment with benzalkonium chloride, it was inferred that these coatings contain accessible porosity and that their initial thromboresistance depends on the formation of the benzalkonium-heparin complex in pores. In vivo tests showed that polished and outgassed, impermeable isotropic carbons deposited at low temperatures were significantly thromboresistant without the exogenous application of heparin. There was no relationship between the amount of heparin sorbed on these materials and their compatibility with blood. Polishing, for example, which reduced heparin sorption, enhanced the thromboresistance of these carbons, and while chemisorption of oxygen markedly reduced their thromboresistance, it did not influence the amount of heparin that could be sorbed. Although the heparin-benzalkonium complex sorbed in a porous carbon conferred excellent thromoboresistance in a 2-hr test, the long-tern (14-day) compatibility was not as good as for carbon surfaces that were deposited at low temperatures and then polished and outgassed prior to implanting. In vivo tests of HTI carbon structures and annealed LTI carbons indicate that the blood compatibility of a turbostratic carbon is not significantly dependent on crystallite size, Le. Limited tests of surfaces that had a preponderance of c-faces oriented parallel to the blood-carbon interface at the surface suggest that orientations of this sort are better than others.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 59-70 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Porous high-density polyethylene specimens were implanted in the femurs of mongrel canines. At the end of the residency period (3 or 6 months), the animals were sacrificed and the implants were retrieved. The work-of-fracture of the implant specimens was then determined using the technique of Tattersall and Tappin. The work required to fracture a specimen in three-point bending by controlled crack propagation through a triangular cross section was obtained directly from the load-deflection curve. The area of the resulting fracture surface was measured by macro-photographic techniques, and the work-of-fracture was calculated as work per unit area. The implants were subsequently sectioned and examined microradiographically to determine the extent of bone ingrowth. Bone specimens adjacent to the implants and porous high-density polyethylene controls (no ingrowth) were also tested to determine their work-of-fracture. The results showed that bone adjacent to the implant specimens had a higher work-of-fracture than normal medial, canine femoral bone and was not appreciably different from the composite. The work-of-fracture of porous high-density polyethylene was not significantly increased by an increase in bone infiltration, and this anomalous behavior was attributed to a degradation of the polyethylene during implant residence. Control studies supported this hypothesis.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 381-398 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Numerous hypotheses exist to explain observed blood-materials interactions. It is the purpose of this article to test two popular hypotheses, namely, the minimum interfacial free energy hypothesis and the optimum polar/apolar ratio hypothesis. Methacrylate polymers and copolymers were characterized using the captive bubble underwater contact angle method; bulk water content was determined by gravimetric methods; streaming potential measurements were made; and surface roughness and possible particulate contamination were evaluated by reflected light microscopy. In vitro blood tests include whole blood clotting time measurements on polymer-coated tubes; centrifugal force platelet adhesion on polymer-coated coverslips; and a measure of the partial thromboplastin time, Russell's viper venom time (Stypven time), and the prothrombin time of native whole blood exposed to polymer-coated microscope slides. Results suggest that platelet adhesion correlates in the opposite direction of whole blood clotting time and partial thromboplastin time, emphasizing the need for a multiparameter approach to blood-materials testing. Based on these tests the minimum interfacial free energy hypothesis is not supported. In fact, the data suggest the opposite to be true. It is apparent that platelet adhesion can be a misleading indicator of blood compatibility. Neither hypotheses can explain the apparent conflict between the platelet adhesion data and the coagulation time data.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Ceramic and ceramic composite materials and devices were developed for specific maxillofacial applications. These applications included: (1) Replacement of hard tissue voids in low stress areas with a phosphate-bonded alumina-foamed ceramic and a calcium aluminate-bonded alumina foam; (2) development of porous ceramic-coated metallic devices for stabilization of mandibles with avulsed segments; (3) development of implantable ceramic tooth roots onto which more or less conventional crowns may be mounted.Efforts to date have been rewarding. Using the rhesus monkey for all experimental implant work, incorporation of porous ceramic foam prostheses to eliminate maxillary defects has been accomplished. Also, we have succeeded in stabilizing the mandible where segments of from 3 to 8 mm were removed. Bridging of the gap with new bone occurred within 6 weeks resulting in a total regeneration of the resected area with restoration of normal mandibular function. Finally, implantable tooth roots were developed. Three different surface treatment techniques have been used on a basic high-density alumina core. The first is a high-density matt finish which can only permit a fibrous tissue attachment or bony approximation but no ingrowth. The second is a porous alumina coating intended to permit bone ingrowth. The third is a rough surface consisting of particles of alumina sintered to the surface to maximize the bone/ceramic interface shear strength potential. Implantations of both anterior and posterior tooth roots with all three surface configurations have been successful for periods of up to six months.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 8 (1974), S. v 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 8 (1974), S. v 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 5 (1971), S. 63-79 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The flexural tests on 37 whole equine metacarpus bones are described and the results are given in terms of fundamental material properties as a function of age. The moduli of elasticity, rupture, and failure increase then decrease with increasing age. The rupture and failure deformations decrease with age. The stiffness and fragility indices increase with age. Averaging the data for all ages, the modulus of rupture was 35 ksi, the deflection at rupture was 0.22 inches, and the modulus of elasticity was 1.7 × 10 psi. The flexural rupture strength is about twice the uniaxial compression strength and about five times greater than the torsional strength for whole bone tests. The moduli of elasticity are about the same for flexure and uniaxial compression, and about five times greater than the torsional modulus of rigidity for whole equine bone.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Calcium aluminate bars were formulated to study the effect of real and simulated biological environments on strength. Static fatigue tests revealed that the strength of these potential internal bone prostheses decreased to ca. 60% of their initial strength after less than 100 min while being held at constant stress in solution. Calcium aluminate bars aged for 12 weeks in water or Ringer solution were also found to exhibit large losses in strength, while bars implanted in vivo for the same period of time weakened somewhat less. Semi-quantitative analysis of the solutions in which the calcium aluminate bars were aged revealed that Al3+ and Ca2+ were being leached from the bars in both the saline and water baths, while the concentration of Mg2+ was decreasing in the Ringer solution.Scanning electron microscope (SEM) studies revealed extensive microstructural changes in specimens aged in water or saline solution for 1 and 12 weeks. Similar but far less extensive changes were seen in bars aged in vivo in rabbits for 12 weeks.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 14 (1980), S. 1-10 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Contact angle studies have been carried out on plasma protein layers adsorbed on selected polymer surfaces under buffered saline at 37°, in an attempt to demonstrate directly a recent suggestion that the interfacial free energy between such protein layers and surrounding liquid phase should be zero at equilibrium. Although an initial contact angle of 180° was always obtained, the angle decayed slowly to a stationary value which varied for any one drop on each polymer surface. The stationary values could be reasonably correlated with the reversible work of adhesion predicted for each polymer/protein combination, suggesting that protein desorption from the solid surface is a dominant event in the contact angle decay process. It is concluded that the data bear more relevance to the protein layer/polymer interface than to the protein layer/solution interface, and that the contact angle technique is not a suitable technique for studying the latter on biomaterials.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 993-1002 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A series of porous polymeric sorbents and activated carbon were used to remove di-isopropyl methylphosphonate (DIMP) from human plasma and normal saline. The sorptive capacities of the commercially available sorbents Amberlite XAD-4, XAD-2, XN1010, and XE348, and Calgon 400 were determined. Butyl- and palmityl-grafted XAD-4 were prepared with graft efficiencies of 32 and 6%, respectively, and tested for sorptive capacities. DIMP removal efficiencies were compared to dialysis with a 1.8 m2 Cordis-Dow hollow fiber artificial kidney (HFAK). Butyl-grafted XAD-4 and active carbon outperformed the other sorbents in removing DIMP from both saline and plasma. An order of magnitude reduction in removal ability was noted for all the adsorbents when the mobile media was plasma. Pronounced plasma precipitation was elicited by activated carbon, an effect not observed with any of the polymeric resins tested. The removal efficiencies on a 18.0 g basis of XAD-4, butyl-grafted XAD-4, and active carbon were comparable to that of the HFAK used in this study. These sorbents, however, possess a macroscopic surface area of approximately 0.1 m2, an order of magnitude lower than that of the HFAK. This reduction in contact area is believed to reduce substantially the possibility of undesirable molecular and cellular effects.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...