ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Bone  (29)
  • NDE  (21)
  • Springer  (50)
  • American Association of Petroleum Geologists (AAPG)
  • Nature Publishing Group
  • 1980-1984  (37)
  • 1975-1979  (13)
  • 1945-1949
Sammlung
Verlag/Herausgeber
  • Springer  (50)
  • American Association of Petroleum Geologists (AAPG)
  • Nature Publishing Group
Erscheinungszeitraum
Jahr
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Calcified tissue international 33 (1981), S. 369-374 
    ISSN: 1432-0827
    Schlagwort(e): Histomorphometry ; Bone ; Reproducibility
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Medizin , Physik
    Notizen: Summary To study bone histomorphometry reproducibility in normal subjects, we performed during orthopedic surgery bone biopsies in 16 post-menopausal women. Each woman had four bone biopsies, two at the usual site in the iliac crest, one on the left and one on the right side, and two other biopsies just behind the usual site, one at each side. We performed measurements of trabecular bone volume, relative osteoid volume, osteoid surfaces, osteoclastic resorption surfaces and calcification front. The average values of the 16 patients were compared, on the one hand, two by two, by a student test, and on the other hand, by a variance analysis. By these two methods the results showed no significant difference between the average values of the 16 patients at each location for any of the histomorphometric parameters studied. However, there was a location variation which was estimated by the intra-individual variation for a given patient. On the other hand, we calculated from the variance analysis the location variance for a group of 10 to 100 patients. In any case all the parameters had a location variation which was high for osteoclastic resorption surfaces and relative osteoid volume when expressed in % of the absolute value of these parameters. The variation of the trabecular bone volume was 0–46. 15% (95% confident limit interval) in a single patient and the hypothetical value of the location variation was 41.6% for a group of 10 patients and 13.0% for a group of 100 patients.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Journal of nondestructive evaluation 3 (1982), S. 65-76 
    ISSN: 1573-4862
    Schlagwort(e): crack measurement ; ac field technique ; arbitrary skin depth ; NDE
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Elektrotechnik, Elektronik, Nachrichtentechnik , Mathematik
    Notizen: Abstract A general solution is given to describe the ac field around surface-breaking cracks for arbitrary values of the ratio of skin depth δ to crack depthd. This solution allows accurate interpretation of crack depth from voltage readings taken by a Crack Microgauge instrument in cases where δ andd are comparable. It is shown to agree with asymptotic formulae obtained for the cases where δ/d is very small and very large. Provided that the probe length Δ is large compared with δ, the calculations show that a very good approximation to the crack depth may be obtained, irrespective of the ratio δ/d, by using the thin-skin asymptotic formula $$d = \frac{1}{2}\Delta (V_2 - V_1 )/V_1 $$ whereV 1 andV 2 are probe voltages registered at positions just off and across the crack, respectively. The problem is solved for a crack of infinite aspect ratio which has no opening, but it can be applied with confidence at the centerline of cracks of fairly large aspect ratio.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Journal of nondestructive evaluation 4 (1984), S. 3-12 
    ISSN: 1573-4862
    Schlagwort(e): Ultrasonic ; stress measurements ; interfacial stress ; NiTi ; NDE
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Elektrotechnik, Elektronik, Nachrichtentechnik , Mathematik
    Notizen: Abstract In seeking to develop an NDE technique for verifying the serviceability of NiTi couplers for plumbing unions, it was found that the reflection coefficient for a normally incident ultrasonic wave correlated with the stress level at the NiTi-tubing interface. Current theory pertaining to interface reflection is not complete but, even at present status, there is semiquantitative accord between theoretical predictions and normalized data for reflection coefficient versus stress level. These results are at fixed frequency and with comparable surface roughness. Variation of either frequency or surface roughness further affects the reflection coefficient. Current studies are being pursued to define this effect.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 195-202 
    ISSN: 1573-4862
    Schlagwort(e): ac potential difference ; fatigue crack measurement ; slots ; artificial flaws ; parasitic voltages ; NDE
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Elektrotechnik, Elektronik, Nachrichtentechnik , Mathematik
    Notizen: Abstract The development of a successful and accurate instrument for measuring surface-breaking cracks in metals using the ac field technique has raised several interesting theoretical problems. Measurements with the instrument, known as the Crack Microgauge, do not rely on any prior calibration against an artificial flaw such as a saw-cut in a test block, but some users accustomed to such a calibration from other devices have nevertheless wished to use the instrument in that fashion and have in some instances reported erroneous results. In this paper, we develop a simple theory to explain and quantify this phenomenon. We calculate the parasitic voltages induced in the instrument probe due to the finite opening possessed by an artificial flaw, and we use these results to reinterpret the instrument readings. Controlled experimental measurements on artificial flaws of rectangular cross-section made in aluminum and in steel are found to be in good agreement with the theory. It is shown, however, that application of the theory requires additional information about the internal phase shift associated with the instrument. To enhance the accuracy of the theory, the effect of the corners of the artificial flaws was also considered, although it was not very influential in this work.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    ISSN: 1573-4862
    Schlagwort(e): stress fields ; microstructure ; J integral ; stress intensity factor ; harness acoustic velocity ; acoustic elasticity ; NDE
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Elektrotechnik, Elektronik, Nachrichtentechnik , Mathematik
    Notizen: Abstract A very precise system for measuring two-dimensional velocity fields in solid samples has been used for nondestructive measurements of both externally applied and residual inhomogeneous stresses in solids,J integrals, stress intensity factors of cracks, and hardness of quenched steel. The longitudinal velocity measurement is based on precise determination of the propagation transit time through the stressed solid specimen using a small diameter, water-coupled acoutic transducer, which is scanned mechanically over the sample. Changes in velocity are then related to changes of stress in the sample by the theory of acoustoelasticity. Similar measurements show a high degree of correlation between longitudinal velocity changes and changes in microstructure in steel samples. Applications to problems of solid mechanics and material science illustrate the utility of this nondestructive measuring technique.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 65-74 
    ISSN: 1573-4862
    Schlagwort(e): NDE ; cast iron ; vibration analysis ; modulus ; strength
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Elektrotechnik, Elektronik, Nachrichtentechnik , Mathematik
    Notizen: Abstract An outline is given of the existing nondestructive vibration tests for cast irons and their drawbacks in terms of the dimensional accuracy of the components. A proposal is made for a new test based on the change of resonant frequency with vibration amplitude exhibited by cast irons. This proposal is evaluated using material data obtained from dynamic tests of a wide range of cast iron specimens. A test rig is described suitable for testing cylindrical cast bars, and typical results are presented in relation to material strength. There is also a brief description of preliminary testing on cast products.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Springer
    Calcified tissue international 23 (1977), S. 283-289 
    ISSN: 1432-0827
    Schlagwort(e): Bone ; Resorption ; Osteoclast ; Quantitation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Medizin , Physik
    Notizen: Summary The stimulation of bone resorption, assessed by the release of45Ca from prelabeled bones, was associated with an increase in number of osteoclasts per bone section in parathyroid hormone (PTH)-treated bones, but not in lipopolysaccharide (LPS)-treated bones. By contrast the number of nuclei per osteoclast increased following LPS treatment, but was not affected by PTH. LPS-treated bones had more multinucleated cells, some having as many as 27 nuclei per osteoclast. More osteoclasts were adjacent to the bone collar in bones treated with LPS or PTH than in control bones. In LPS-treated bones this area also contained the largest osteoclasts, as determined by the greatest number of nuclei per osteoclast. The results suggest that LPS and PTH stimulate osteoclastic resorption by different mechanisms.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    Springer
    Calcified tissue international 27 (1979), S. 95-99 
    ISSN: 1432-0827
    Schlagwort(e): Bone ; Fluoride ; Analysis ; Food ; Age
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Medizin , Physik
    Notizen: Summary Recently published bone fluoride values from Iowa are very high compared to earlier reports, suggesting an increase in fluoride intake. Reanalysis of the Iowa specimens shows levels one-fourth those reported by the Iowa laboratory indicating an error in the original report. Seventeen bone specimens, collected from long-term residents of Rochester, New York, drinking 1 ppm F− water, had a mean value of 2085±270 ppm F− on an ashed-weight basis. This value is not significantly different from that predicted by the data of Zipkin et al. in 1958. These data, therefore, do not support the contention that there has been an increase in fluoride intake.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Springer
    Calcified tissue international 28 (1979), S. 33-36 
    ISSN: 1432-0827
    Schlagwort(e): Infrared, visible light ; Bone ; Collagen ; Apatite
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Medizin , Physik
    Notizen: Abstract Photovoltaic effect (infrared and visible light) is observed in bone and its two major components, collagen and apatite, at room temperature. A dimunition in the magnitude of photovoltage is observed after exposure to ultraviolet light in all the cases. The drift mobility of the charge carriers is obtained by measuring I versus V relationships in sandwich samples and relating them to the permitivity of the medium. Lifetime of the injected carriers is measured in the usual way. The data are consistent with the hypothesis that the effects are due to protonic conduction phenomena.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    Springer
    Calcified tissue international 24 (1977), S. 93-98 
    ISSN: 1432-0827
    Schlagwort(e): Magnesium ; Bone ; Mineral ; Chick embryo ; Organ culture
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Medizin , Physik
    Notizen: Summary Using bone organ culture techniques, three concentrations of magnesium were evaluated for their effects on the mineral mass of embryonic chick tibiae incubated for 3 days with or without a metabolic inhibitor (1 mM iodoacetic acid) added to the media. Varying the medium Mg level from 0.3 to 3.0 mM had little effect on the net increase in mineral in live bones (without the inhibitor), but in dead tibiae (with the inhibitor) there was a marked net decrease in mineral deposition with increasing Mg concentration. Bone Mg mass varied directly with the level of Mg in the medium regardless of whether or not the tibiae were inhibited. Responsiveness to parathyroid hormone (PTH) with regard to mineral loss and increased lactate production was not affected by Mg even in tibiae incubated in Mg-free media. However, PTH-treated bones cultured in Mg-free media had a significantly elevated Mg mass, suggesting that the hormone may have a Mg-conserving effect on bone during severe Mg deficiency. The findings of this study support the hypothesis that bone cells regulate the level of Mg to which newly forming mineral is exposed and that PTH-responsiveness in embryonic chick tibiae is not dependent on the ambient Mg concentration.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...