Description:
A cleaning technique widely used by the nuclear utility industry for removal of radioactive surface contamination has proven effective at removing non-hazardous contaminant particles as small as 0.1 micrometer. The process employs a controlled high velocity liquid spray inside a vapor containment enclosure to remove particles from a surface. The viscous drag force generated by the cleaning fluid applies a shear stress greater than the adhesion force that holds small particles to a substrate. Fluid mechanics and field tests indicate general cleaning parameters.
Keywords:
SPACECRAFT DESIGN, TESTING AND PERFORMANCE
Type:
NASA- Goddard Space Flight Center, Greenbelt, Md. Fourteenth Space Simulation Conference: Testing for a Permanent Presence in Space; p 73-94