Publication Date:
2019-06-28
Description:
Preliminary calibrations were performed on nine flow angularity probes in the Langley 7- by 10-Foot High-Speed Tunnel (7 x 10 HST) and the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT). These probes will be used in surveying the test section flows of the National Transonic Facility (NTF). The probes used in this study have a pyramid head with five pressure orifices. The calibrations consisted of both isolated probe measurements and rake-mounted multiprobe measurements that covered a range of subsonic Mach numbers up to 0.90 and Reynolds numbers per foot up to 40 X 10 to the 6th power. The preliminary calibration in the 7 x 10 HST included testing the probes both individually and in a rake. The 0.3-m TCT calibration tested two probes singly at varying Reynolds numbers. The results from these tests include Mach number, Reynolds number, and rake-mounting effects. The results of these tests showed probe sensitivity to be slightly affected by Mach number. At Reynolds numbers per foot above 10 x 10 to the 6th power, the probe did not exhibit a Reynolds number sensitivity.
Keywords:
AERODYNAMICS
Type:
NASA-TM-87750
,
L-16069
,
NAS 1.15:87750
Format:
application/pdf
Permalink